top of page
Dive into seamless power protection with the MODULYS RM GP, a 3-phase modular UPS system designed for effortless 19-inch rack integration. This system provides maximum availability and robust power protection in a compact design, freeing up valuable rack space. Enjoy simplified management and maintenance, ensuring your critical loads are always humming along perfectly.

Model 8U
Number of Power Modules 1 to 2 x 25kW
Configuration N+1 to N+1 redundant
Power (kVA) 25 to 50kVA
Power (kW) 25 to 50kW
Input/Output 3/3
Voltage 480V 3ph (240V to 480V)
Frequency 60Hz ±10%
Power Factor (PF) >0.99
Output Voltage 480V ±1%
Output Frequency 60Hz ±0.1%
Voltage Distortion <1% (linear load); <6% (non-linear load according to IEC 62040-3)
Short-Circuit Current Up to 3 In
Overload 125% for 10 minutes, 150% for 1 minute
Crest Factor 3:1
Hot-Swap Bypass Model 8U
Hot-Swap Bypass Voltage Rated output voltage ±10% (configurable from 10% to 20%)
Hot-Swap Bypass Frequency 60Hz ±2% (configurable for Genset compatibility)
Hot-Swap Bypass Weight 15.4 lbs
Ambient Temperature 32°F to 104°F (for maximum battery life)
Relative Humidity 0 to 95% without condensation
Maximum Altitude 3280 feet without derating (10000 feet max)
Acoustic Level at 3 feet <52dBA
UPS Rack Dimensions (W x D x H) 17.32 in x 36.22 in x 15.75 in (8U)
UPS Rack Weight 79.2 lbs (empty cabinet)
Degree of Protection IP20
Hot-Swap Power Module Height 2U
Hot-Swap Power Module Weight 74.8 lbs
Hot-Swap Power Module Type Hot plug-in / hot swappable
MTBF >1,000,000 hours (calculated and verified)
Hot-Swap Battery Rack Type Acid leak-proof - Long Life batteries
Hot-Swap Battery Rack Protection Independent protection for each battery string
Hot-Swap Battery Rack Dimensions 17.32 in x 33.86 in x 15.75 in (4U)
Hot-Swap Battery Rack Weight 77 lbs (empty rack)
Safety Standard IEC/EN 62040-1
EMC Standard IEC/EN 62040-2 Class C3
Performance Standard IEC/EN 62040-3
Product Certification

MODULYS RM GP Rack-Mounted Modular UPS System: 25-75 kVA/kW for Critical Loads

  • Strong Points

    • Full rack integration
    • Overall cost optimisation
    • Totally redundant design
    • Automatic firmware allignment
    • Enhanced serviceability performance
    • ‘Forever Young’ concept

    Function

    MODULYS RM GP is a 3-phase modular UPS system designed for 19” rack integration.
    Easy to integrate and install whilst simple to manage and maintain, it provides maximum availability and power protection in a compact design leaving free space for other rack-mounted devices.

    Conformity to standards

    EN 62040-1, EN 60950-1, EN 62040-2, EN 62040-3 (VFI-SS-111)
    CE
    RCM (E2376)
    EAC

    Applications

    • Data center - Power availability for telecom
    • Data center - Power availability for edge
    • Industry - Power availability for industrial process

INDIGI POWER & COOLING
SALES@INDIGIPC.COM.AU
1800 046 344
BRISBANE, QLD 4000
ABN 37688860442

bottom of page