{"product_id":"evikon-e2218-humidity-temperature-transmitter","title":"Evikon E2218 Humidity \u0026 Temperature Transmitter","description":"\u003ch1 id=\"evikon-e2218-humidity-and-temperature-transmitter\" class=\"font-editorial font-bold first:mt-xs mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg leading-[1.5em] lg:text-xl\"\u003eEvikon E2218 Humidity and Temperature Transmitter\u003c\/h1\u003e\n\u003ch2 id=\"industrial-humidity-and-temperature-monitoring-for\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eIndustrial Humidity and Temperature Monitoring for Data Centres, Server Rooms and HVAC Applications\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Evikon E2218 is an industrial-grade humidity and temperature transmitter designed for accurate, continuous measurement of relative humidity, absolute humidity, temperature, and dew point in air and non-aggressive gas environments. Part of the Evikon PluraSens family, it features two freely configurable analog outputs, RS485 Modbus RTU digital interface, and IP65 protection, making it suitable for direct integration with BMS, SCADA, and building automation systems in data centres, precision cooling environments, and commercial HVAC plant rooms.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSupplied by Indigi Power \u0026amp; Cooling across Australia.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"applications\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eData centres and server rooms (temperature and humidity compliance monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCRAC and CRAH precision cooling environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eUPS and battery rooms (humidity monitoring for equipment protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCommercial and industrial HVAC plant rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCold storage and controlled environment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eBuilding automation and energy management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"why-humidity-and-temperature-monitoring-matters-in\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eWhy Humidity and Temperature Monitoring Matters in Data Centres\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eASHRAE recommends maintaining server room intake temperature between 18 and 27 degrees C, with relative humidity between 20 and 80% for most IT equipment classes. Humidity that falls too low creates electrostatic discharge risk. Humidity that rises too high risks condensation on equipment and corrosion over time. Temperature excursions directly degrade UPS battery performance, reduce CRAC cooling efficiency, and shorten the service life of IT equipment.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe E2218 provides continuous, accurate measurement with resolution down to 0.01% RH and 0.01 degrees C, giving facilities management teams the real-time visibility needed to maintain conditions within specification. With RS485 Modbus RTU and analog 4-20 mA or 0-10 V outputs, it integrates directly with any modern BMS platform for logging, alarming, and automated HVAC response.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"technical-specifications\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group relative my-[1em]\"\u003e\n\u003cdiv aria-hidden=\"true\" class=\"sticky top-0 z-10 h-0\"\u003e\n\u003cdiv class=\"w-full overflow-hidden bg-raised border-x md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full overflow-auto scrollbar-subtle rounded-lg border md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-raised\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\" scope=\"col\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\" scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eE2218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003ePluraSens (Evikon MCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eRelative humidity (%RH), absolute humidity, temperature, dew point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 100 %RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e-40 to +85 degrees C (standard); -40 to +125 degrees C option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0.01 %RH \/ 0.01 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e+\/-2.5 %RH, +\/-0.3 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eHigh Accuracy Option\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e+\/-1.8 %RH, +\/-0.3 degrees C (on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 x 3-wire 0-10 V or 4-20 mA, programmable and freely scalable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDigital Interface\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eProbe Options\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eAttached or remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e12 to 36 VDC (default); 24 VAC option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e-40 to +85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 100 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eEMC Compliance\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2014\/30\/EU, EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eCertifications\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"key-features\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eMeasures relative humidity, absolute humidity, temperature, and dew point simultaneously\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eResolution of 0.01 %RH and 0.01 degrees C for precise environmental monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eTwo independently programmable analog outputs — 4-20 mA or 0-10 V, freely scalable within measurement range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eRS485 Modbus RTU for direct integration with BMS, SCADA, and building automation platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAttached or remote probe options for flexible installation in confined or hard-to-access locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIP65 rated industrial enclosure for plant room and controlled environment applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWide power supply compatibility: 12 to 36 VDC standard, 24 VAC option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eHigh accuracy variant available on request (plus or minus 1.8 %RH)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eOperating range down to -40 degrees C for cold environment installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"documents\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eDocuments\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2218_DS_EN.pdf\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eE2218 Technical Datasheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2218_UM_EN.pdf\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eE2218 User Manual (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2218_CE_EN.pdf\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eCE Declaration of Conformity (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"supply-by-indigi-power--cooling\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eSupply by Indigi Power \u0026amp; Cooling\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIndigi Power \u0026amp; Cooling supplies Evikon MCI sensors and transmitters across Queensland, New South Wales, Victoria, and Papua New Guinea. The E2218 is suited to data centre and server room environmental monitoring programmes, CRAC cooling system integration, and BMS humidity and temperature sensing for critical infrastructure facilities.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 id=\"related-products-and-services\" class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\"\u003eRelated Products and Services\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/products\/evikon-e2673-off-gassing-detector\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eEvikon E2673 Off-Gassing Detector (H2 and VOC)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/products\/evikon-e2638-hfc-refrigerant-detector\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eEvikon E2638-HFC Refrigerant Detector\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/products\/evikon-e2608-nh3-ammonia-detector\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eEvikon E2608-NH3-E Ammonia Detector\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"noopener\" title=\"Gas Detection for Battery Rooms \u0026amp; BESS\" href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/gas-detection-battery-rooms-data-centres-bess\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eGas Detection for Battery Rooms, Data Centres and BESS\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/pages\/crac-unit-maintenance-services\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eCRAC Unit Maintenance Services\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/crac-units-australia-complete-guide-precision-cooling-data-centres\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" rel=\"nofollow noopener\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eCRAC Units Explained\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51910771409216,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/302-humidity-temperature-transmitter-2.jpg?v=1777520371","url":"https:\/\/www.indigipc.com.au\/products\/evikon-e2218-humidity-temperature-transmitter","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}