{"product_id":"evikon-e2608-nh3-ammonia-detector","title":"Evikon E2608-NH3-E Ammonia Detector | Indigi Power","description":"\u003ch1 class=\"font-editorial font-bold first:mt-xs mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg leading-[1.5em] lg:text-xl\" id=\"evikon-e2608-nh3-e-ammonia-detector\"\u003eEvikon E2608-NH3-E Ammonia Detector\u003c\/h1\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"fixed-ammonia-gas-detection-for-refrigeration-plan\"\u003eFixed Ammonia Gas Detection for Refrigeration Plants, Cold Storage and Industrial Facilities\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe Evikon E2608-NH3-E is a fixed ammonia detector-transmitter designed for continuous leak monitoring in refrigeration facilities, cold storage warehouses, and industrial plant rooms where ammonia (NH3) is used as a refrigerant. Part of the Evikon PluraSens family, it uses a fully calibrated, temperature-compensated electrochemical sensor with four selectable detection ranges up to 5,000 ppm, and resolution down to 1 ppm.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAmmonia is one of the most widely used industrial refrigerants due to its high efficiency, but it presents serious health and safety risks at low concentrations. At 25 ppm, ammonia causes eye and respiratory irritation. At 300 ppm it becomes immediately dangerous to life and health. Continuous fixed monitoring with automatic alarm and ventilation control is the standard approach to managing ammonia leak risk in commercial and industrial environments.\u003c\/p\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSupplied by Indigi Power \u0026amp; Cooling across Australia.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"applications\"\u003eApplications\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eRefrigeration plants using ammonia as a primary refrigerant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eCold storage warehouses and distribution centres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFood processing and beverage manufacturing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIndustrial HVAC plant rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSkating arenas and large-scale cooling facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eAny enclosed environment where ammonia refrigerant is in use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group relative my-[1em]\"\u003e\n\u003cdiv class=\"sticky top-0 z-10 h-0\" aria-hidden=\"true\"\u003e\n\u003cdiv class=\"w-full overflow-hidden bg-raised border-x md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"w-full overflow-auto scrollbar-subtle rounded-lg border md:max-w-[90vw] border-subtlest ring-subtlest divide-subtlest bg-raised\"\u003e\n\u003ctable class=\"[\u0026amp;_tr:last-child_td]:border-b-0 my-0 w-full table-auto border-separate border-spacing-0 text-sm font-sans rounded-lg [\u0026amp;_tr:last-child_td:first-child]:rounded-bl-lg [\u0026amp;_tr:last-child_td:last-child]:rounded-br-lg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" class=\"border-subtlest p-sm min-w-[48px] break-normal border-b text-left align-bottom border-r last:border-r-0 font-bold bg-subtle first:border-radius-tl-lg last:border-radius-tr-lg\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eE2608-NH3-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003ePluraSens (Evikon MCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eGas Detected\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eSensor Technology\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eElectrochemical (fully calibrated, temperature compensated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eSampling Method\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDetection Ranges\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 100 ppm NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 300 ppm NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 1,000 ppm NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e0 to 5,000 ppm NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eUp to 10,000 ppm available on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e1 ppm NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDefault Alarm Setpoints\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e25 ppm (Alarm 1) \/ 35 ppm (Alarm 2) — user settable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eSensor Lifetime\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eGreater than 2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e12 to 36 VDC (default); 24 VAC or 230 VAC options available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDigital Interface\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 x 4-20 mA or 0-10 V, user settable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e2 x SPST relays (closing contact), rated 250 VAC \/ 30 VDC, 5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eGrey ABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eIP Rating\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eH85 x W82 x D55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e-40 to +50 degrees C (0 to 5,000 ppm range: -30 to +50 degrees C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003e15 to 90 %RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eCertifications\u003c\/td\u003e\n\u003ctd class=\"border-subtlest px-sm min-w-[48px] break-normal border-b border-r last:border-r-0\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"key-features\"\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFully calibrated temperature-compensated electrochemical sensor for accurate, stable ammonia measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eFour selectable detection ranges from 0 to 100 ppm through to 0 to 5,000 ppm; up to 10,000 ppm on request\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e1 ppm resolution for reliable early detection at low concentrations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eTwo user-settable alarm setpoints — default 25 ppm and 35 ppm aligned to safety thresholds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eTwo SPST relay outputs for direct connection to ventilation fans, sirens, or fire panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eDual analog outputs (4-20 mA or 0-10 V) and RS485 Modbus RTU for BMS and SCADA integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIP65 rated wall-mount ABS enclosure suitable for plant room and industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eWide power supply compatibility from 12 VDC through to 230 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eSuitable for operating temperatures down to -40 degrees C for cold environment installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"important-application-note\"\u003eImportant Application Note\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eThe E2608-NH3-E is designed for refrigeration leak detection applications where ammonia concentrations are typically low. It is not recommended for use in spaces with constantly elevated ammonia levels such as livestock facilities, as prolonged high-concentration exposure reduces sensor lifetime.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"documents\"\u003eDocuments\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2608-NH3-E_DS_EN.pdf\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eE2608-NH3-E Technical Datasheet (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2608-NH3-E_UM_EN.pdf\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eE2608-NH3-E User Manual (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/evikon.eu\/pdf\/evikon\/E2608_CE_EN.pdf\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eCE Declaration of Conformity (PDF)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"supply-and-installation-by-indigi-power--cooling\"\u003eSupply and Installation by Indigi Power \u0026amp; Cooling\u003c\/h2\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003eIndigi Power \u0026amp; Cooling supplies Evikon MCI gas detection equipment and provides installation, commissioning, and integration services across Queensland, New South Wales, Victoria, and Papua New Guinea. The E2608-NH3-E is installed as part of a complete ammonia safety solution including sensor placement design based on ammonia density and airflow patterns, relay wiring to ventilation control or alarm systems, and analog or RS485 integration to your BMS or SCADA platform.\u003c\/p\u003e\n\u003chr class=\"bg-quiet h-px border-0\"\u003e\n\u003ch2 class=\"font-editorial font-bold mb-2 mt-4 [.has-inline-images_\u0026amp;]:clear-end text-lg first:mt-0 md:text-lg [hr+\u0026amp;]:mt-4\" id=\"related-products-and-services\"\u003eRelated Products and Services\u003c\/h2\u003e\n\u003cul class=\"marker:text-quiet list-disc pl-8\"\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/www.indigipc.com.au\/products\/evikon-e2673-off-gassing-detector\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eEvikon E2673 Off-Gassing Detector (H2 and VOC)\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/www.indigipc.com.au\/products\/evikon-e2638-hfc-refrigerant-detector\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eEvikon E2638-HFC Refrigerant Detector\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/gas-detection-battery-rooms-data-centres-bess\" target=\"_blank\" title=\"Gas Detection for Battery Rooms \u0026amp; BESS \" rel=\"noopener\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eGas Detection for Battery Rooms, Data Centres and BESS\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/www.indigipc.com.au\/pages\/crac-unit-maintenance-services\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eCRAC Unit Maintenance Services\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"py-0 my-0 prose-p:pt-0 prose-p:mb-2 prose-p:my-0 [\u0026amp;\u0026gt;p]:pt-0 [\u0026amp;\u0026gt;p]:mb-2 [\u0026amp;\u0026gt;p]:my-0\"\u003e\n\u003cp class=\"my-2 [\u0026amp;+p]:mt-4 [\u0026amp;_strong:has(+br)]:inline-block [\u0026amp;_strong:has(+br)]:pb-2\"\u003e\u003ca rel=\"nofollow noopener\" class=\"reset interactable cursor-pointer decoration-1 underline-offset-1 text-super hover:underline\" href=\"https:\/\/www.indigipc.com.au\/pages\/design-deployment-services\" target=\"_blank\"\u003e\u003cspan class=\"text-box-trim-both\"\u003eUPS Installation and Maintenance\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51910511198528,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/Ammoniadetector-transmitterE2608-NH3-E.webp?v=1777519481","url":"https:\/\/www.indigipc.com.au\/products\/evikon-e2608-nh3-ammonia-detector","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}