{"product_id":"stulz-cyberair-mini-server-room-air-conditioning-australia","title":"STULZ CyberAir Mini Server Room Air Conditioning Units Australia","description":"\u003cdiv style=\"box-sizing:border-box;max-width:960px;margin:0 auto;padding:28px 20px;font-family:Arial,Helvetica,sans-serif;font-size:17px;line-height:1.6;color:#222222;\"\u003e\n\n\u003cp style=\"font-size:15px;color:#888888;text-transform:uppercase;letter-spacing:0.5px;margin:0 0 10px 0;\"\u003eHome \/ Precision Cooling \/ STULZ \/ CyberAir Mini\u003c\/p\u003e\n\n\u003cdiv style=\"background-color:#fafafa;border-left:4px solid #d9590c;border-radius:6px;padding:16px 20px;margin-bottom:28px;\"\u003e\n  \u003cp style=\"margin:0;font-size:19px;\"\u003e\n    \u003cstrong\u003eThe STULZ CyberAir Mini is a precision server room air conditioning unit delivering 5.9 kW to 34.7 kW of cooling in four sizes, designed for small server rooms, comms rooms, UPS rooms and battery rooms across Australia.\u003c\/strong\u003e\n    It is the direct successor to the STULZ MiniSpace range, and it is built to put the maximum cooling capacity into the smallest possible footprint, with cabinets from 540 mm to 1,140 mm wide that fit through a standard doorway. Indigi Power and Cooling supplies, installs, commissions and maintains CyberAir Mini units nationally from hubs in Brisbane, Sydney and Melbourne.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eMost Australian IT rooms are not data halls. They are a 10 to 40 square metre room in an office floor, a hospital wing, a council depot or a school, carrying anywhere from four to twenty racks plus a UPS and its batteries. That room still needs the same things a data hall needs: stable supply air temperature, tight humidity control, continuous 24\/7 duty and filtration that keeps dust off the electronics. What it does not have is floor space, a plant room, or a budget that stretches to a 100 kW machine.\u003c\/p\u003e\n\n\u003cp\u003eThe CyberAir Mini exists for exactly that gap. It covers 5.9 kW to 34.7 kW across four cabinet sizes and six cooling systems, with airflow from 1,800 to 9,200 cubic metres per hour. STULZ builds it to deliver the maximum cooling capacity from a minimal footprint, using the largest heat exchanger and filter surface areas that will fit inside the cabinet, EC fan technology and intelligent control to hold running costs down. It is a computer room air conditioning unit in the proper sense, sized on sensible heat and running every hour of the year, not a comfort split system asked to do a job it was never designed for.\u003c\/p\u003e\n\n\u003cp\u003eIndigi Power and Cooling is an Indigenous and Veteran owned critical power and cooling specialist, registered with Supply Nation and ICN Gateway. We supply, install, commission and maintain CyberAir Mini units across Australia, and we also service the large installed base of older STULZ MiniSpace equipment already running in Australian comms rooms.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eMiniSpace becomes CyberAir Mini\u003c\/h2\u003e\n\n\u003cp\u003eIf you have a STULZ unit in your comms room that was specified any time from the late 1990s through to the early 2020s, there is a good chance it is a MiniSpace. STULZ has renamed and re-engineered that range as the CyberAir Mini, bringing it into line with the CyberAir naming used across the rest of the precision cooling portfolio. The product does the same job in the same part of the market. It is the small-capacity, floor-standing, front-access precision unit for rooms that are too small for a data hall CRAC and too critical for a comfort system.\u003c\/p\u003e\n\n\u003cp\u003eThe commercial point matters more than the naming. Australian sites searching for STULZ MiniSpace parts, service or a like-for-like replacement are now looking at a product with a different name, and that creates a genuine risk of a facilities manager concluding the range has been discontinued and defaulting to a comfort split. It has not been discontinued. It has been superseded, and the successor is a better unit.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 10px 0;\"\u003eThe upgrade path from an existing MiniSpace\u003c\/h3\u003e\n\n\u003cp\u003eA MiniSpace to CyberAir Mini replacement is usually one of the simpler precision cooling projects on a site, because the fundamentals carry across. Cabinet height remains 1,980 mm, which is the dimension that most often governs whether a unit will physically go into an existing room with a suspended ceiling. Widths of 540 mm, 740 mm, 940 mm and 1,140 mm sit in the same family of footprints. Front access servicing means the replacement can go back against the same wall in the same position. Where the existing unit is chilled water fed, the pipework route, the condensate drain and the electrical supply are frequently reusable with minor modification.\u003c\/p\u003e\n\n\u003cp\u003eWhat changes is the efficiency and the control. Current EC fan technology, larger heat exchanger surface area and the modern STULZ controller with its optional touchscreen typically produce a material reduction in fan energy and a much better part-load response than a unit designed two decades ago. Refrigerant is the other driver. Older units commonly ran R407C or R22 in the oldest cases, whereas current DX CyberAir Mini units use R513A at GWP 631 and the hybrid Free Cooling variants use R454C at GWP 148.\u003c\/p\u003e\n\n\u003cp\u003eThe practical sequence we run is a site survey and heat load verification, a selection against the actual measured IT load rather than the nameplate of the outgoing unit, a staged changeover plan that keeps the room cooled while the swap happens, and full commissioning with documented handover. On a single-unit room that usually means temporary cooling for the changeover window. On a room with N+1 already in place it can often be done one unit at a time with no temporary hire at all.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eWhy the CyberAir Mini suits small rooms\u003c\/h2\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:14px;margin-bottom:28px;\"\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eCapacity from a tiny footprint\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eThe smallest cabinet is 540 mm wide and 540 mm deep and still delivers 5.9 kW. The largest is 1,140 mm wide and delivers 34.7 kW. Every size is 1,980 mm high and passes through a standard door.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eEER up to 22.25\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eOn chilled water the CCD 90 CW reaches an Energy Efficiency Ratio of 22.25 at 10\/15 degrees Celsius water. Even the least efficient CW model in the range sits at 17.78.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eSix cooling systems\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eA air cooled, AS air cooled with EC compressor, G water cooled, GE hybrid Free Cooling, CW chilled water and ACW chilled water with a redundant air cooled circuit in the same cabinet.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eQuiet enough for an office floor\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eChilled water models run from 46 dB(A) on the CCD 90 CW. That matters when the comms room shares a wall with occupied space, which is the normal case in Australian tenancies.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eLow GWP refrigerants\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eR513A at GWP 631 on the air cooled A systems and R454C at GWP 148 on the GE hybrid Free Cooling systems, which keeps the site ahead of the HFC phase-down schedule.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eFront access, wall mountable position\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eAll maintainable components are reached from the front, so the unit sits flat against a wall and does not consume the clearance a rear-access machine would need.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eRange specification at a glance\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: STULZ CyberAir Mini headline specification across the full range\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eParameter\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e5.9 kW to 34.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAirflow volume\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e1,800 to 9,200 cubic metres per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eNumber of sizes\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eFour cabinet sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAir conduction\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eUpflow (CCU) and downflow (CCD), with intake and exhaust front and left, left only, or all directions\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCooling systems\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eA, AS, G, GE, CW, ACW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 mm on every size in the range\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eWidth and depth\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e540 x 540 mm, 740 x 540 mm, 940 x 640 mm, 1,140 x 640 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eRefrigerants\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eR513A (GWP 631) on A systems, R454C (GWP 148) on GE hybrid Free Cooling systems\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eSound pressure\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e46 to 59 dB(A) on chilled water models, 59 to 72 dB(A) on DX and hybrid models\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eOptions\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eDirect and Indirect Free Cooling, pressure independent control valve for CW, filter classes, heating, humidification\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eControl\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eSTULZ controller, optional touchscreen, intelligent capacity control across the unit group\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eModel tables: chilled water (CW)\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberAir Mini chilled water models. Conditions: return air 26 degrees Celsius at 40 per cent relative humidity, glycol 0 per cent, water 10\/15 degrees Celsius, 400 V \/ 3 ph \/ 50 Hz, 20 Pa external static pressure.\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eModel\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAir conduction\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eCooling kW\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAirflow m³\/h\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eEER\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSound dB(A)\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;\"\u003eH x W x D mm\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 90 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDownflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e8.9\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e2,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e22.25\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e46\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCU 90 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUpflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e8.9\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e2,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e17.80\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e50\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 180 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDownflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e16.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,500\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e20.00\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e53\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCU 180 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUpflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e16.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,500\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e17.78\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e54\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 260 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDownflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e24.5\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e6,600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e20.42\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e55\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCU 260 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUpflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e24.5\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e6,600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e18.85\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e56\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 350 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDownflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e34.7\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e9,200\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e20.41\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e58\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 1,140 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eCCU 350 CW\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003eUpflow\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e34.7\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e9,200\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e19.28\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e59\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;\"\u003e1,980 x 1,140 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThe chilled water models are the efficiency story in this range. An EER of 22.25 on the CCD 90 CW means the unit is moving roughly 22 kW of heat for every kilowatt of electrical input at the stated conditions, because there is no compressor in the unit. That only applies where the building already has a chilled water plant with capacity to spare and a service agreement that guarantees it runs outside business hours, which is the usual catch in a commercial tenancy. Where the plant shuts down at night or on weekends, chilled water alone is not a safe basis for a critical room, and the ACW dual-fluid option or a DX selection is the better answer.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eModel tables: air cooled (A) and hybrid Free Cooling (GE)\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:24px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberAir Mini air cooled DX models. Conditions: return air 33 degrees Celsius at 30 per cent relative humidity, glycol 0 per cent, refrigerant R513A (GWP 631).\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eModel\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eCooling kW\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAirflow m³\/h\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eEER\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSound dB(A)\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;\"\u003eH x W x D mm\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 41 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e5.9\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.92\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 61 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e8.2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e2,100\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.82\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e63\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 81 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e10.3\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e2,700\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.90\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e67\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 111 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.3\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3,100\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.52\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e70\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 141 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e14.1\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.70\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e67\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eCCD 171 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e16.8\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e5,200\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e4.80\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e68\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberAir Mini GE hybrid Free Cooling models. Same return air conditions, refrigerant R454C (GWP 148).\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eModel\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eCooling kW\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAirflow m³\/h\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eEER\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSound dB(A)\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;\"\u003eH x W x D mm\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 41 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e8.1\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,700\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.50\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e59\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 61 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e10.3\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,900\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3.96\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e62\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 540 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 81 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e12.2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e2,700\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3.81\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e69\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 111 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e13.6\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3,100\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3.68\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e72\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 740 x 540\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCCD 141 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e20.5\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4.36\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e70\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eCCD 171 GE\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e22.7\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e5,100\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e4.05\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e71\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;\"\u003e1,980 x 940 x 640\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:15px;color:#555555;margin-bottom:28px;\"\u003eUpflow (CCU) variants of the DX and GE models, AS units with a variable speed EC compressor, water cooled G units and ACW dual-fluid selections are quoted on application. Send us your heat load and site conditions and we will run the selection properly rather than picking off a table.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eReading a CyberAir Mini model number\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberAir Mini nomenclature, worked through CCD 350 CW and CCD 141 A\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eElement\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eMeaning\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eExample\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCC\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCyberAir Mini family identifier\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eCommon to every model in the range\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eD or U\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAir conduction direction. D is downflow, U is upflow.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eCCD 350 CW is downflow, CCU 350 CW is the upflow equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eLeading digits\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eNominal cooling capacity in kW. Rated output varies with the conditions quoted in each table.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e35 in CCD 350 CW, rated at 34.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFinal digit\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eNumber of refrigerant circuits. Zero where there is no refrigerant circuit at all.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e0 in CCD 350 CW because chilled water units have none, 1 in CCD 141 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eSuffix\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;\"\u003eCooling system: A, AS, G, GE, CW or ACW\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eCW in CCD 350 CW is chilled water, A in CCD 141 A is air cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eChoosing between the six cooling systems\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberAir Mini cooling system options and where each one fits an Australian small room\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSystem\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eDescription\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eTypical fit\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eA\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAir cooled direct expansion with an external air cooled condenser, running R513A at GWP 631.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eThe default for a standalone comms room with roof or courtyard space for a condenser. Fully independent of the base building.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAS\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAs A, with a variable speed EC compressor instead of an on\/off compressor.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eRooms where the IT load varies through the day or grows over time. Part-load efficiency and temperature stability are both better.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eG\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eWater cooled with a direct evaporator. Heat goes to a water or glycol loop and out through an external dry cooler.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eMulti-tenant towers and heritage buildings where a long refrigerant run to a condenser is not practical or not permitted.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eGE\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHybrid Free Cooling. G system plus an integrated Free Cooling coil, running R454C at GWP 148.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eMelbourne, Canberra, Hobart, Adelaide and inland NSW, where cool shoulder-season hours pay back the premium.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCW\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eChilled water. No compressor in the unit, so EER reaches 22.25 on the smallest downflow model.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eBuildings with a 24\/7 chilled water plant and a written commitment that it stays available outside business hours.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eACW\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;\"\u003eDual fluid. Chilled water primary with a fully independent air cooled DX circuit inside the same cabinet.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eThe answer where chilled water is cheap but not guaranteed. The room survives a plant outage without a second unit or a second footprint.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eUpflow, downflow and air conduction in a small room\u003c\/h2\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:18px;margin-bottom:24px;\"\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:16px;background-color:#fafafa;text-align:center;\"\u003e\n\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:0 0 6px 0;\"\u003eCCD Downflow\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#555;margin:0;text-align:left;\"\u003eWarm return air enters at the top, passes the heat exchanger and is discharged down into a raised floor void. The right choice where the room already has a floor plenum feeding perforated tiles at the rack fronts.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:16px;background-color:#fafafa;text-align:center;\"\u003e\n\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:0 0 6px 0;\"\u003eCCU Upflow\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#555;margin:0;text-align:left;\"\u003eDischarge from the top of the unit, free blowing or ducted. This is the common Australian retrofit case, because most comms rooms in existing buildings have a slab floor and no void to work with.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:16px;background-color:#fafafa;text-align:center;\"\u003e\n\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:0 0 6px 0;\"\u003eIntake and exhaust options\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#555;margin:0;text-align:left;\"\u003eAir conduction can be configured front and left, left only, or in all directions. In a narrow room that flexibility is often what decides whether the unit can be placed at all.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eAir conduction deserves more attention on a small room than it usually gets. In a 30 square metre comms room the unit is only a few metres from the racks, so a poorly chosen discharge direction produces short cycling, where cold supply air finds its way straight back to the return without passing through a single server. The symptom is a room that reads cold at the CRAC and hot at the top of the third rack. Getting the intake and exhaust configuration right at selection stage costs nothing. Fixing it afterwards means ductwork, blanking panels and often a return visit.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eSizing a CyberAir Mini for a UPS room or battery room\u003c\/h2\u003e\n\n\u003cp\u003eUPS rooms and battery rooms are the applications where a small precision unit earns its cost most clearly, and they are also the ones most often sized wrongly. Three things separate them from a normal server room.\u003c\/p\u003e\n\n\u003cp\u003eFirst, the heat load is not the UPS rating. A 40 kVA three-phase UPS running at 60 per cent load at 95 per cent efficiency rejects only a couple of kilowatts of heat, not 40. Sizing on the nameplate is the single most common error we see, and it produces an oversized unit that short cycles, controls poorly and wears its compressor out early. Our \u003ca href=\"\/pages\/server-room-heat-load-calculator\" style=\"color:#d9590c;\"\u003eserver room heat load calculator\u003c\/a\u003e works this through properly, and we verify it against measured draw during a site visit.\u003c\/p\u003e\n\n\u003cp\u003eSecond, battery rooms are temperature-critical in a way server rooms are not. VRLA battery life halves for roughly every 8 to 10 degrees Celsius above 20 to 25 degrees Celsius. A battery string sitting at 35 degrees in an unconditioned room will not deliver its rated runtime and will need replacing in a fraction of its design life, which is a far larger cost than the cooling that would have prevented it. Holding the room at 20 to 25 degrees Celsius is the whole reason a battery room gets a precision unit rather than a wall split.\u003c\/p\u003e\n\n\u003cp\u003eThird, ventilation obligations apply. Vented lead-acid and some VRLA installations require mechanical ventilation to control hydrogen concentration, and where a mechanical ventilation system serves the space, AS\/NZS 3666 hygiene obligations for air handling apply alongside it. Cooling and ventilation need to be designed together, not bolted on in sequence. See our \u003ca href=\"\/pages\/server-room-ups-cooling-australia\" style=\"color:#d9590c;\"\u003eserver room UPS and cooling packages\u003c\/a\u003e for how we scope the two as one job.\u003c\/p\u003e\n\n\u003cp\u003eA practical rule for the small end: a 10 to 15 rack room with a UPS typically lands somewhere between 8 kW and 25 kW of sensible load once you account for lighting, envelope gain and people, which puts it squarely across the CCD 61 A to CCD 350 CW span. Two smaller units in N+1 are almost always a better answer than one larger unit, because a single unit means a single point of failure and no capacity to service the machine without shutting the room's cooling down entirely.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eFree Cooling and control options\u003c\/h2\u003e\n\n\u003cp\u003eBoth Direct and Indirect Free Cooling are available as options across the range. Direct Free Cooling draws filtered outside air into the room when conditions allow, which is the cheapest possible cooling but exposes the space to outside air quality. In coastal Australian locations, salt-laden air, and in summer, bushfire smoke, are real considerations that belong in the design conversation rather than being discovered later. Indirect Free Cooling keeps outside air out of the room entirely and rejects heat through a water or glycol circuit to an external dry cooler, with the integrated Free Cooling coil in the GE units doing the work whenever ambient conditions permit.\u003c\/p\u003e\n\n\u003cp\u003eOn chilled water selections, the pressure independent control valve option is worth specifying. It holds the design flow rate through the coil regardless of pressure fluctuations elsewhere in the building loop, which matters in a shared plant where other tenants' valves are constantly modulating. Paired with energy-efficient pumps it removes a class of control instability that is otherwise very hard to diagnose from inside the comms room.\u003c\/p\u003e\n\n\u003cp\u003eBeyond that, the option list covers different filter classes, various heating options and humidification. Filtration is specified to ISO 16890, and on a small room the filter is the component that most often causes a slow, unexplained loss of capacity. The STULZ controller flags filter condition, but it needs someone to be reading the alarms. The controller itself is available with an optional touchscreen and supports intelligent capacity control across a group of units, so an N+1 pair sequences rather than fighting each other.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:17px;padding-left:22px;margin-bottom:28px;\"\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eSmall \u003ca href=\"\/pages\/server-room-cooling-australia\" style=\"color:#d9590c;\"\u003eserver rooms and comms rooms\u003c\/a\u003e from roughly four racks up to twenty, where a full data hall CRAC is oversized and a comfort split is unsuitable\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eUPS rooms and battery rooms needing a stable 20 to 25 degrees Celsius to protect battery design life, covered in our \u003ca href=\"\/pages\/server-room-ups-cooling-australia\" style=\"color:#d9590c;\"\u003eserver room UPS and cooling\u003c\/a\u003e packages\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eEquipment rooms, MDF and IDF rooms, and network riser rooms in commercial towers\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eRetrofits into existing buildings where the doorway, the ceiling height and the absence of a raised floor all constrain what can physically be installed\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eHospital, pathology and diagnostic imaging IT rooms with continuous uptime obligations\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eCouncil, utility, rail and defence control rooms operating under APRA CPS 230 style operational resilience expectations\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eBuildings on a central chilled water plant, where \u003ca href=\"\/pages\/chw-crac-maintenance-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCHW CRAC arrangements\u003c\/a\u003e or an ACW dual-fluid unit make the most sense\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eCyberAir Mini compared with Vertiv Liebert Mini-Mate\u003c\/h2\u003e\n\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: Indicative comparison against the nearest small-capacity Vertiv precision unit. Figures are manufacturer published, rating conditions differ between the two brands, and Vertiv model availability varies by market. Treat this as an orientation guide rather than a like-for-like benchmark, and ask us for a compared selection on your actual conditions.\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSTULZ CyberAir Mini\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eVertiv Liebert Mini-Mate\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCapacity band\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e5.9 kW to 34.7 kW across four sizes\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eSmall-capacity band, broadly overlapping at the lower end and typically not reaching the top of the CyberAir Mini range\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eInstallation form\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFloor standing, 1,980 mm high, 540 mm to 1,140 mm wide, front access\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eCommonly specified as a ceiling-mounted or above-ceiling unit, which frees floor area but complicates service access\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCooling system choice\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eSix systems: A, AS, G, GE, CW and ACW dual fluid\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eDX and chilled water variants offered, with a narrower set of hybrid and dual-fluid options\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eLowest GWP refrigerant\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eR454C at GWP 148 on GE hybrid Free Cooling\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eCurrent-generation Vertiv small units are moving to lower GWP blends, so check the specific model offered\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003ePredecessor range\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDirect successor to STULZ MiniSpace, with a straightforward upgrade path\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eLong-running Liebert small-room line with its own installed base in Australia\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eAustralian service\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;\"\u003eIndigi Power and Cooling, national coverage from Brisbane, Sydney and Melbourne\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eIndigi services Liebert equipment too. See our \u003ca href=\"\/pages\/liebert-crac-spare-parts-australia-emerson-vertiv-cooling-components\" style=\"color:#d9590c;\"\u003eLiebert spare parts page\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eInstallation, commissioning and maintenance in Australia\u003c\/h2\u003e\n\n\u003cp\u003eA CyberAir Mini installation is a licensed job on two fronts. All electrical work must be carried out by a licensed electrician to AS\/NZS 3000, and any work on the refrigerant circuit requires an ARCtick licensed refrigeration technician under the Ozone Protection and Synthetic Greenhouse Gas Management Regulations. Where the unit forms part of a mechanical ventilation system, which is common in UPS and battery rooms, AS\/NZS 3666 hygiene obligations for air handling systems apply as well. Indigi carries out all three in house rather than subcontracting the critical path.\u003c\/p\u003e\n\n\u003cp\u003eA typical scope covers heat load verification against measured IT draw rather than nameplate ratings, condenser or dry cooler siting and pipe run design, rigging and placement into what is often a tight room with a single narrow door, refrigerant charging and leak testing, condensate drainage and pump-up where there is no gravity fall available, controller configuration and BMS integration, sequencing setup where two units run in N+1, and witness commissioning with a documented handover pack. Indicative pricing for server room cooling design and installation in the small band, which is where most CyberAir Mini projects sit, runs from $8,000 to $15,000. Medium installations run $25,000 to $45,000. Final scope always depends on the site, and condenser access is usually the variable that moves the number most.\u003c\/p\u003e\n\n\u003cp\u003eOnce running, a small room actually needs more maintenance discipline than a large one, not less, because there is rarely any redundancy to hide behind. The schedule should cover filter condition and replacement, coil cleanliness, condensate management, refrigerant charge and leak checks, compressor and EC fan health, humidifier service where fitted, and a review of the controller alarm history rather than just a glance at the current state. See our \u003ca href=\"\/pages\/crac-unit-maintenance-services\" style=\"color:#d9590c;\"\u003eCRAC unit maintenance services\u003c\/a\u003e, \u003ca href=\"\/pages\/dx-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eDX CRAC servicing\u003c\/a\u003e and \u003ca href=\"\/pages\/crac-installation-commissioning-australia\" style=\"color:#d9590c;\"\u003eCRAC installation and commissioning\u003c\/a\u003e pages for how we structure the work. Where the same room holds a UPS, we combine cooling and UPS attendance into one visit. UPS one-off maintenance is $720 ex GST and the standard annual plan is $1,940 per year ex GST.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhat size room does the STULZ CyberAir Mini suit?\u003c\/h3\u003e\n\u003cp\u003eThe CyberAir Mini covers 5.9 kW to 34.7 kW of cooling across four cabinet sizes, with airflow from 1,800 to 9,200 cubic metres per hour. In practice that suits small server rooms, comms rooms, equipment rooms, UPS rooms and battery rooms from roughly four racks up to about twenty, depending on rack density. Above that band the STULZ CyberAir 3PRO range is the better selection.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eIs the CyberAir Mini the replacement for the STULZ MiniSpace?\u003c\/h3\u003e\n\u003cp\u003eYes. MiniSpace becomes CyberAir Mini. STULZ has renamed and re-engineered the MiniSpace range as the CyberAir Mini to align it with the wider CyberAir portfolio. It occupies the same position in the market, keeps the 1,980 mm cabinet height that usually governs whether a unit fits an existing room, and offers a straightforward upgrade path for the installed base of MiniSpace units in Australian comms rooms. Indigi services existing MiniSpace units and quotes like-for-like CyberAir Mini replacements.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhat is the difference between the CCD downflow and CCU upflow models?\u003c\/h3\u003e\n\u003cp\u003eCCD is downflow, discharging cold air down into a raised floor void for distribution through perforated tiles. CCU is upflow, discharging from the top of the unit either free blowing or ducted, which suits rooms with a slab floor and no void. Most Australian retrofits into existing buildings end up as upflow. Downflow models also post better EER figures, for example 22.25 on the CCD 90 CW against 17.80 on the CCU 90 CW.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eCan a CyberAir Mini cool a UPS room or battery room?\u003c\/h3\u003e\n\u003cp\u003eYes, and it is one of the primary applications for the range. Battery rooms need to be held at roughly 20 to 25 degrees Celsius, because VRLA battery life halves for approximately every 8 to 10 degrees Celsius above that band. Size on the actual heat rejected by the UPS, which is the loss rather than the kVA rating, not on the nameplate. Where mechanical ventilation is required for hydrogen control, AS\/NZS 3666 hygiene obligations apply alongside the cooling design.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhich cooling system should I choose for a small server room?\u003c\/h3\u003e\n\u003cp\u003eFor a standalone room with roof or courtyard space for a condenser, the air cooled A or AS system is the default because it is independent of the base building. Where the building has a 24\/7 chilled water plant, CW gives the best efficiency, with EER up to 22.25. Where chilled water exists but is not guaranteed outside business hours, ACW dual fluid adds an independent air cooled circuit inside the same cabinet. In cooler southern climates, GE hybrid Free Cooling with R454C usually returns the lowest running cost.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eHow much does server room air conditioning cost to install in Australia?\u003c\/h3\u003e\n\u003cp\u003eIndigi's indicative pricing for server room cooling design and installation is $8,000 to $15,000 for a small room, $25,000 to $45,000 for a medium installation and $45,000 to $60,000 plus for a large project. Most CyberAir Mini projects sit in the small band. The variables that move the figure most are condenser or dry cooler siting, pipe run length, electrical supply upgrades and whether the room needs temporary cooling during a changeover.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWho installs and services STULZ CyberAir Mini units in Australia?\u003c\/h3\u003e\n\u003cp\u003eIndigi Power and Cooling supplies, installs, commissions and maintains STULZ precision cooling equipment across Australia from hubs in Brisbane, Sydney and Melbourne. Electrical work is carried out to AS\/NZS 3000 and all refrigerant work by ARCtick licensed technicians. We also service existing STULZ MiniSpace and CyberAir units installed by others, and can combine cooling and UPS maintenance into a single site attendance.\u003c\/p\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eWhere we install and service\u003c\/h2\u003e\n\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:16px;margin-bottom:32px;\"\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/ups-battery-crac-maintenance-brisbane\" style=\"color:#111111;text-decoration:none;\"\u003eBrisbane and QLD\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eBrisbane CBD, Woolloongabba, Eight Mile Plains, Port of Brisbane, Gold Coast, Sunshine Coast, Ipswich, Townsville, Cairns\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eNational HQ at Tingalpa. Fastest response and stocked spares for small server room units across South East Queensland.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/ups-data-centre-cooling-maintenance-sydney\" style=\"color:#111111;text-decoration:none;\"\u003eSydney and NSW\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eSydney CBD, Parramatta, North Ryde, Macquarie Park, Western Sydney, Newcastle, Wollongong, Canberra (ACT)\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eHeavy demand for CBD tower comms room retrofits, where doorway width and no raised floor drive the selection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/critical-power-crac-maintenance-melbourne\" style=\"color:#111111;text-decoration:none;\"\u003eMelbourne and VIC\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eMelbourne CBD, Port Melbourne, Docklands, Dandenong, Tullamarine, Geelong, Ballarat, regional Victoria\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eBest Free Cooling hours on the mainland. GE hybrid selections repay their premium fastest in Victorian comms rooms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003ePerth and WA\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003ePerth CBD, Fremantle, Kalgoorlie, Pilbara, regional WA\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eResources sector equipment rooms with high ambient design conditions. Condenser sizing is the critical variable.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003eAdelaide and SA\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eAdelaide CBD, Port Adelaide, Salisbury, Mount Gambier, Whyalla, regional SA\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eGood shoulder-season Free Cooling hours. Served from the Melbourne hub on planned schedules.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003eDarwin and NT\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eDarwin CBD, Palmerston, Katherine, Alice Springs, remote NT sites\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eHigh humidity design conditions. Latent load and condensate handling need specific attention on small rooms.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background-color:#111111;border-radius:8px;padding:16px 20px;margin-bottom:32px;\"\u003e\n  \u003cp style=\"color:#ffffff;margin:0;\"\u003e\n    \u003cstrong\u003eWestern Australia, Tasmania and Pacific Islands:\u003c\/strong\u003e we schedule CyberAir Mini installation and service visits in planned blocks to keep travel costs down, and we can combine comms room cooling work with UPS and battery attendance in a single mobilisation.\n    \u003ca href=\"\/pages\/contact\" style=\"color:#d9590c;\"\u003eContact us to discuss scheduling.\u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eRelated products and services\u003c\/h2\u003e\n\u003cul style=\"font-size:17px;padding-left:22px;margin-bottom:28px;\"\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-cooling-australia\" style=\"color:#d9590c;\"\u003eServer room cooling Australia\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-ups-cooling-australia\" style=\"color:#d9590c;\"\u003eServer room UPS and cooling packages\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-heat-load-calculator\" style=\"color:#d9590c;\"\u003eServer room heat load calculator\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-topology-selector-australia\" style=\"color:#d9590c;\"\u003eCRAC topology selector: DX, CHW or CDW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-unit-maintenance-services\" style=\"color:#d9590c;\"\u003eCRAC unit maintenance services Australia\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/dx-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eDX CRAC servicing across Brisbane, Sydney and Melbourne\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/chw-crac-maintenance-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCHW CRAC maintenance for chilled water units\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/cdw-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCDW CRAC servicing\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-installation-commissioning-australia\" style=\"color:#d9590c;\"\u003eCRAC installation and commissioning\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;\" role=\"presentation\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"background-color:#111111;border-radius:10px;padding:28px 24px;text-align:center;\"\u003e\n      \u003cp style=\"color:#ffffff;font-size:21px;font-weight:800;margin-top:0;margin-bottom:10px;\"\u003eGet a CyberAir Mini selection for your server room\u003c\/p\u003e\n      \u003cp style=\"color:#cfcfcf;font-size:16px;margin-top:0;margin-bottom:18px;\"\u003eSend us your rack count, UPS rating, room dimensions, doorway width and location, and tell us whether you have a raised floor and access to chilled water. We will come back with a sized selection, a condenser or dry cooler plan and an installed price. If you are replacing a STULZ MiniSpace, send the model plate photo as well. Indigi Power and Cooling is Indigenous and Veteran owned, and registered with Supply Nation and ICN Gateway.\u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background-color:#d9590c;color:#ffffff;font-weight:700;text-decoration:none;padding:12px 28px;border-radius:6px;\"\u003eContact Indigi Power and Cooling\u003c\/a\u003e\n    \u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Product\",\"name\":\"STULZ CyberAir Mini Server Room Air Conditioning Units Australia\",\"description\":\"Precision server room air conditioning unit for small server rooms, comms rooms, UPS rooms and battery rooms. 5.9 kW to 34.7 kW in four sizes, upflow and downflow, with air cooled, water cooled, hybrid Free Cooling, chilled water and dual fluid systems. Successor to the STULZ MiniSpace range. Supplied, installed and serviced across Australia by Indigi Power and Cooling.\",\"brand\":{\"@type\":\"Brand\",\"name\":\"STULZ\"},\"category\":\"Computer Room Air Conditioning (CRAC)\",\"offers\":{\"@type\":\"Offer\",\"availability\":\"https:\/\/schema.org\/InStock\",\"seller\":{\"@type\":\"Organization\",\"name\":\"Indigi Power and Cooling\",\"url\":\"https:\/\/www.indigipc.com.au\",\"telephone\":\"1800046344\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"10\/240 New Cleveland Road\",\"addressLocality\":\"Tingalpa\",\"addressRegion\":\"QLD\",\"postalCode\":\"4173\",\"addressCountry\":\"AU\"}},\"areaServed\":\"AU\"},\"model\":[\"CCD 90 CW\",\"CCU 90 CW\",\"CCD 180 CW\",\"CCU 180 CW\",\"CCD 260 CW\",\"CCU 260 CW\",\"CCD 350 CW\",\"CCU 350 CW\",\"CCD 41 A\",\"CCD 61 A\",\"CCD 81 A\",\"CCD 111 A\",\"CCD 141 A\",\"CCD 171 A\",\"CCD 41 GE\",\"CCD 61 GE\",\"CCD 81 GE\",\"CCD 111 GE\",\"CCD 141 GE\",\"CCD 171 GE\"],\"additionalProperty\":[{\"@type\":\"PropertyValue\",\"name\":\"Cooling capacity\",\"value\":\"5.9 kW to 34.7 kW\"},{\"@type\":\"PropertyValue\",\"name\":\"Airflow volume\",\"value\":\"1,800 to 9,200 m3\/h\"},{\"@type\":\"PropertyValue\",\"name\":\"Cooling systems\",\"value\":\"A, AS, G, GE, CW, ACW\"},{\"@type\":\"PropertyValue\",\"name\":\"Refrigerants\",\"value\":\"R513A (GWP 631), R454C (GWP 148)\"},{\"@type\":\"PropertyValue\",\"name\":\"Cabinet height\",\"value\":\"1,980 mm\"},{\"@type\":\"PropertyValue\",\"name\":\"Predecessor range\",\"value\":\"STULZ MiniSpace\"}]}\n\u003c\/script\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What size room does the STULZ CyberAir Mini suit?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The CyberAir Mini covers 5.9 kW to 34.7 kW of cooling across four cabinet sizes, with airflow from 1,800 to 9,200 cubic metres per hour. That suits small server rooms, comms rooms, equipment rooms, UPS rooms and battery rooms from roughly four racks up to about twenty, depending on rack density. Above that band the STULZ CyberAir 3PRO range is the better selection.\"}},\n{\"@type\":\"Question\",\"name\":\"Is the CyberAir Mini the replacement for the STULZ MiniSpace?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. MiniSpace becomes CyberAir Mini. STULZ has renamed and re-engineered the MiniSpace range as the CyberAir Mini to align it with the wider CyberAir portfolio. It occupies the same position in the market, keeps the 1,980 mm cabinet height that usually governs whether a unit fits an existing room, and offers a straightforward upgrade path for the installed base of MiniSpace units in Australian comms rooms. Indigi services existing MiniSpace units and quotes like-for-like CyberAir Mini replacements.\"}},\n{\"@type\":\"Question\",\"name\":\"What is the difference between the CCD downflow and CCU upflow models?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"CCD is downflow, discharging cold air down into a raised floor void for distribution through perforated tiles. CCU is upflow, discharging from the top of the unit either free blowing or ducted, which suits rooms with a slab floor and no void. Most Australian retrofits into existing buildings end up as upflow. Downflow models also post better EER figures, for example 22.25 on the CCD 90 CW against 17.80 on the CCU 90 CW.\"}},\n{\"@type\":\"Question\",\"name\":\"Can a CyberAir Mini cool a UPS room or battery room?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, and it is one of the primary applications for the range. Battery rooms need to be held at roughly 20 to 25 degrees Celsius, because VRLA battery life halves for approximately every 8 to 10 degrees Celsius above that band. Size on the actual heat rejected by the UPS, which is the loss rather than the kVA rating. Where mechanical ventilation is required for hydrogen control, AS\/NZS 3666 hygiene obligations apply alongside the cooling design.\"}},\n{\"@type\":\"Question\",\"name\":\"Which cooling system should I choose for a small server room?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For a standalone room with roof or courtyard space for a condenser, the air cooled A or AS system is the default because it is independent of the base building. Where the building has a 24\/7 chilled water plant, CW gives the best efficiency, with EER up to 22.25. Where chilled water exists but is not guaranteed outside business hours, ACW dual fluid adds an independent air cooled circuit inside the same cabinet. In cooler southern climates, GE hybrid Free Cooling with R454C usually returns the lowest running cost.\"}},\n{\"@type\":\"Question\",\"name\":\"How much does server room air conditioning cost to install in Australia?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Indigi's indicative pricing for server room cooling design and installation is $8,000 to $15,000 for a small room, $25,000 to $45,000 for a medium installation and $45,000 to $60,000 plus for a large project. Most CyberAir Mini projects sit in the small band. The variables that move the figure most are condenser or dry cooler siting, pipe run length, electrical supply upgrades and whether the room needs temporary cooling during a changeover.\"}},\n{\"@type\":\"Question\",\"name\":\"Who installs and services STULZ CyberAir Mini units in Australia?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Indigi Power and Cooling supplies, installs, commissions and maintains STULZ precision cooling equipment across Australia from hubs in Brisbane, Sydney and Melbourne. Electrical work is carried out to AS\/NZS 3000 and all refrigerant work by ARCtick licensed technicians. Indigi also services existing STULZ MiniSpace and CyberAir units installed by others, and can combine cooling and UPS maintenance into a single site attendance.\"}}\n]}\n\u003c\/script\u003e","brand":"STULZ","offers":[{"title":"Default Title","offer_id":52961634484544,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/CyberAir_Mini_800x800px.jpg?v=1786195503","url":"https:\/\/www.indigipc.com.au\/products\/stulz-cyberair-mini-server-room-air-conditioning-australia","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}