{"product_id":"stulz-cyberrow-in-row-rack-cooling-australia","title":"STULZ CyberRow In Row Cooling Units Australia","description":"\u003cdiv style=\"box-sizing:border-box;max-width:960px;margin:0 auto;padding:28px 20px;font-family:Arial,Helvetica,sans-serif;font-size:17px;line-height:1.6;color:#222222;\"\u003e\n\u003cp style=\"font-size:15px;color:#888888;text-transform:uppercase;letter-spacing:0.5px;margin:0 0 10px 0;\"\u003eHome \/ Precision Cooling \/ STULZ \/ CyberRow In Row Cooling\u003c\/p\u003e\n\u003cdiv style=\"background-color:#fafafa;border-left:4px solid #d9590c;border-radius:6px;padding:16px 20px;margin-bottom:28px;\"\u003e\n  \u003cp style=\"margin:0;font-size:19px;\"\u003e\n    \u003cstrong\u003eThe STULZ CyberRow is an in row cooling unit that stands directly between the server racks, delivering 11 kW to 58 kW of cooling and 3,200 to 11,200 cubic metres per hour of airflow to high density racks in Australian data centres, with or without a raised floor.\u003c\/strong\u003e\n    Each unit cools up to six server cabinets, uses horizontal air conduction to build a virtual containment around the racks it serves, and regulates three separate horizontal zones with up to five independently variable EC fans. Indigi Power and Cooling supplies, installs, commissions and maintains CyberRow in row cooling units nationally from hubs in Brisbane, Sydney and Melbourne.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eRack densities have moved. A data hall designed a decade ago sized 3 kW to 5 kW per cabinet and pushed cold air out of a floor void to the room at large. A hall carrying GPU compute, virtualisation clusters or dense blade chassis now routinely sees 15 kW, 25 kW or more in a single cabinet, and a room level cooling strategy simply cannot deliver enough air to the front of those racks fast enough. The result is a hot spot: one or two cabinets running well above the rest of the hall while the perimeter CRAC units work hard and over supply everything else.\u003c\/p\u003e\n\u003cp\u003eIn row cooling solves that by shortening the air path. The CyberRow is a narrow cabinet, 300 mm, 400 mm or 600 mm wide and 1,950 mm high, that is bolted into the row alongside the racks it serves. Air travels metres rather than tens of metres, and because the unit is measuring temperature at the racks themselves rather than at a return grille on the wall, it responds to what the servers are actually experiencing. STULZ describes the CyberRow as professional server rack cooling with innovative air conduction, and the design intent shows in the details: horizontal air distribution, up to five independent fans, and six temperature sensors across the front and rear faces.\u003c\/p\u003e\n\u003cp\u003eIndigi Power and Cooling is an Indigenous and Veteran owned critical power and cooling specialist, registered with Supply Nation and ICN Gateway. We supply, install, commission and maintain STULZ in row cooling across Australia, and we also service the installed base of in row and perimeter equipment already running in Australian facilities, including units from other manufacturers.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eSee the CyberRow in operation\u003c\/h2\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden;border-radius:8px;margin-bottom:10px;background:#111111;\"\u003e\n  \u003ciframe src=\"https:\/\/www.youtube.com\/embed\/kowII0KbOg8\" title=\"STULZ CyberRow (english)\" frameborder=\"0\" loading=\"lazy\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0;\"\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:14px;color:#888888;margin:0 0 28px 0;\"\u003eSTULZ CyberRow (english), 3 minutes 4 seconds. Walks through the housing, filter, fan arrangement, service access and connection options.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eWhy the CyberRow suits high density rack cooling\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(260px,1fr));gap:14px;margin-bottom:28px;\"\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eSix cabinets per unit\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eSTULZ rates each CyberRow at up to six server cabinets. Cooling is targeted at the racks in the row rather than diluted across the whole white space.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eNo raised floor required\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eThe unit is suitable for data centres with or without a floor void, which removes the single biggest obstacle to retrofitting cooling into an existing comms room.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eThree zone regulation\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eUp to five variable speed EC fans and six temperature sensors adapt cooling capacity in three horizontal zones, so a hot top of rack is fixed without over cooling the bottom.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eVirtual containment\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eThe optimised horizontal air pattern creates a virtual containment around the served racks even where no physical aisle enclosure has been built.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eAny rack manufacturer\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eNo direct cable or refrigerant connection is required between rack and unit, so the CyberRow drops into rows of any brand of cabinet with real installation flexibility.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background-color:#111111;border-radius:8px;padding:18px 20px;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#d9590c;margin:0 0 8px 0;\"\u003eFront and rear service access\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#e8e8e8;margin:0;\"\u003eDoors front and rear, a pivoting electrical box and a zigzag G4 filter in a metal frame mean maintenance happens from the aisle without pulling the unit out of the row.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eRange specification at a glance\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: STULZ CyberRow headline specification across the full in row cooling range\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eParameter\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eTotal cooling capacity\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e11 kW to 58 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAirflow volume\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e3,200 to 11,200 cubic metres per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eRacks cooled per unit\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eUp to six server cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eSizes\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e6 sizes, 3 widths and 2 depths\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e1,950 mm across the range\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e300 mm, 400 mm or 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eDepth\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e1,175 mm or 1,200 mm (CRS short), 1,375 mm (CRL long)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eRack footprints referenced\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003e1,200 \/ 1,000 \/ 600 \/ 400 \/ 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAir conduction\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eLeft and right, to the left, to the right, or forward (frontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCooling systems\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eA\/AS air cooled, GS water cooled, GES hybrid Free Cooling, CW and CW2 chilled water\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eRefrigerants\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eR410A (GWP 2,088), R134a (GWP 1,430)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFans\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eUp to five independent variable speed EC fans in three horizontal zones\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCompressor\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eVariable speed EC compressor with integrated soft start (AS, GS, GES)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFiltration\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eZigzag G4 filter with metal frame, accessible from the aisle\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eControl and BMS\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eSTULZ controller, six temperature sensors, two independent setpoints, RS-485 serial port standard for Modbus and STULZ protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eModel table: CyberRow DX and hybrid Free Cooling\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:16px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: STULZ CyberRow air cooled, water cooled and hybrid Free Cooling models. Data at return air 35 degrees Celsius and 25 per cent relative humidity. CRS denotes the short depth cabinet and CRL the long depth cabinet.\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eModel\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAirflow m³\/h\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eCooling kW\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eIndirect Free Cooling kW\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eHeight mm\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eWidth mm\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;\"\u003eDepth mm\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 101 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3,200\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,200 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 211 A\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e20.3\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,200 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 211 AS\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e4,600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e22.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,200 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 251 A\/AS\/GS\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e5,400\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e25.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,175 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 361 A\/AS\/GS\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e8,000\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e37.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003en\/a\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,175 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCRS\/CRL 251 GES\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e5,400\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e25.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e21.5\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e400\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-bottom:1px solid #e3e3e3;\"\u003e1,175 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eCRS\/CRL 361 GES\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e8,000\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e37.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e30.9\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e1,950\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;\"\u003e600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;\"\u003e1,175 or 1,375\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:15px;color:#555555;margin-bottom:28px;\"\u003eThe 11 kW to 58 kW headline range covers the whole CyberRow family. The DX and hybrid Free Cooling models tabled above run from 11.4 kW to 37 kW at the stated return air condition; the top of the range and the 11,200 cubic metre per hour airflow figure are reached on CW and CW2 chilled water configurations. Ratings move with return air temperature, humidity and chilled water flow and temperature, so treat the table as a selection starting point and let us run the numbers against your actual conditions.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eHot aisle and cold aisle containment\u003c\/h2\u003e\n\u003cp\u003eContainment is where in row cooling either works properly or quietly fails. The point of any containment scheme is to stop cold supply air and hot exhaust air mixing, because every degree of mixing is capacity you paid for and did not deliver to a server inlet. The CyberRow supports both of the standard containment strategies, and the correct choice drives which air conduction option you order.\u003c\/p\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:18px;margin-bottom:24px;\"\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:16px;background-color:#fafafa;text-align:center;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:0 0 6px 0;\"\u003eCold aisle containment\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#555;margin:0;text-align:left;\"\u003eUnits with a frontal air outlet blow straight down the enclosed cold aisle. STULZ positions them at an offset to one another so the whole aisle is supplied rather than just the neighbouring cabinets, which evens out inlet temperatures along the run.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:16px;background-color:#fafafa;text-align:center;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:0 0 6px 0;\"\u003eHot aisle containment\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;color:#555;margin:0;text-align:left;\"\u003eUnits with side air conduction take return air from the contained hot aisle and expel cold air sideways into the room, which distributes supply air uniformly along the length of the aisle instead of concentrating it in front of one or two cabinets.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eWhere no physical containment has been built, the CyberRow still improves on room level cooling because the optimised horizontal air pattern forms what STULZ calls a virtual containment. Cold air is thrown along the front of the rack line and hot air is collected close to where it is produced, so the mixing that normally occurs in an open hall is substantially reduced without erecting doors and roof panels. That matters in Australian comms rooms and small data halls where the room is shared, the ceiling is low, or the building owner will not permit structural aisle work.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eThree zone control and Delta T regulation\u003c\/h2\u003e\n\u003cp\u003eA tall cabinet does not have one temperature. The top of a 42U rack running dense compute is frequently several degrees warmer than the bottom, and a cooling unit that reads a single average will either starve the top or over cool the whole rack to protect it. The CyberRow addresses this with three temperature sensors on the front, three on the back, and up to five independently variable EC fans.\u003c\/p\u003e\n\u003cp\u003eThe controller measures Delta T between supply and return across each of three horizontal zones and adapts cooling capacity in each zone individually. In practice one fan bank may sit at 42 per cent while the two above it run at 65 and 67 per cent, because that is what the racks in front of them are asking for. Hot spots are removed without the energy penalty of an across the board over supply, and because EC fan power varies roughly with the cube of speed, small reductions in fan duty produce disproportionately large savings on a 24 hour a day load.\u003c\/p\u003e\n\u003cp\u003eThe controller also carries two mutually independent setpoints, typically a fixed supply air setpoint and a fixed Delta T setpoint between supply and return air. Holding both at once is what allows precise temperature control at the server inlet while still managing the volume of air moved, rather than trading one against the other. STULZ develops the controller in house, which is why the Free Cooling operating modes, the zone logic and the fan redundancy behaviour are handled as one integrated control strategy rather than bolted together from third party parts.\u003c\/p\u003e\n\u003cp\u003eFan redundancy is worth calling out separately. If a fan fails, the remaining fans automatically speed up to hold capacity, so a single fan fault does not become a thermal event while a technician is dispatched. The controller monitors and reports all faults, and a standard RS-485 serial port allows integration into a building management system over Modbus or STULZ protocols. Optional humidity sensor, electric heater and humidifier are available where the room needs active humidity control as well as sensible cooling.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eChoosing between the cooling systems\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: CyberRow cooling system options and where each one fits an Australian site\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSystem\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eDescription\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eTypical fit\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eA \/ AS\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eAir cooled direct expansion with an external air cooled condenser. AS adds the variable speed EC compressor with integrated soft start.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eServer rooms and small data halls with roof or ground level condenser space and no chilled water plant.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eGS\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eWater cooled. Heat is transferred to a water or glycol circuit and rejected through an external dry cooler.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eMulti tenant buildings and long pipe runs, where refrigerant charge and pipe length need to be minimised.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eGES\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHybrid Free Cooling with Indirect Dynamic Free Cooling. Rated at 21.5 kW (251) and 30.9 kW (361) in Free Cooling mode.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eMelbourne, Canberra, Hobart and inland New South Wales sites chasing the lowest annual running cost.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCW\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eChilled water. No compressor in the unit; capacity comes from the building chilled water plant.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eFacilities already on central chilled water, and the route to the top of the capacity range.\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eCW2\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;\"\u003eChilled water with a redundant supply. One unit connects to two independent chilled water circuits.\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eSites that need cooling to survive the loss of one chilled water circuit without installing a second unit.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eCW2 deserves a note of its own, because redundancy at the unit is usually cheaper and simpler than redundancy at the row. Connecting a single CyberRow to two mutually independent chilled water circuits means a ruptured pipe, a failed pump or a valve isolation on one circuit does not take that unit offline. For a facility working to an APRA CPS 230 style operational resilience obligation, that is a materially easier story to write up than an N+1 argument that depends on neighbouring units picking up a failed unit's load.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eInstallation detail that matters on site\u003c\/h2\u003e\n\u003cp\u003eSeveral CyberRow design decisions exist specifically to make the retrofit case work. There is no direct cable or refrigerant connection between the rack and the cooling unit, so the unit can be positioned wherever the thermal model wants it without being tied to a particular cabinet. Water connection openings are pre cut as standard at both the top and the bottom of the cabinet, which means the same unit suits an overhead reticulation design or an under floor one without site fabrication. The housing is powder coated with doors front and rear, and the electrical box pivots out for service, so a technician working in a live aisle is not forced to break containment or shut down a neighbouring rack to reach a component.\u003c\/p\u003e\n\u003cp\u003eThe zigzag G4 filter sits in a metal frame and is changed from the aisle. On a continuously running unit the filter is the most common cause of a gradual, unnoticed capacity loss, so filter change intervals should be set against the actual dust load of the room rather than a generic annual schedule. Rooms in industrial estates, near construction, or on sites with regular door traffic will need shorter intervals than a sealed CBD comms room.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"font-size:17px;padding-left:22px;margin-bottom:28px;\"\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eHigh density rack cooling for AI and GPU compute, where a handful of cabinets carry far more load than the rest of the hall\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eRetrofit cooling into existing \u003ca href=\"\/pages\/server-room-cooling-australia\" style=\"color:#d9590c;\"\u003eserver rooms and comms rooms\u003c\/a\u003e that have no raised floor and no room for a perimeter unit\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eHot aisle or cold aisle containment pods inside a larger colocation or enterprise data hall\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eTargeted supplementary cooling alongside existing perimeter CRAC units, resolving hot spots without resizing the whole plant\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eModular and phased build outs, where cooling capacity is added row by row as racks are populated\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eChilled water facilities needing unit level redundancy through CW2, complementing \u003ca href=\"\/pages\/chw-crac-maintenance-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCHW CRAC arrangements\u003c\/a\u003e\n\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003eCombined critical power and cooling projects delivered as \u003ca href=\"\/pages\/server-room-ups-cooling-australia\" style=\"color:#d9590c;\"\u003eserver room UPS and cooling packages\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eCyberRow compared with Vertiv Liebert CRV\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:28px;\"\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:15px;line-height:1.4;\"\u003e\n    \u003ccaption style=\"caption-side:top;text-align:left;font-size:14px;color:#777777;padding:0 0 8px 2px;\"\u003eTable: Indicative comparison against the closest in row competitor. Figures are manufacturer published, rating conditions differ between vendors, and configurations vary by market, so treat this as an orientation guide rather than a like for like benchmark.\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eAttribute\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eSTULZ CyberRow\u003c\/th\u003e\n        \u003cth scope=\"col\" style=\"padding:13px 16px;text-align:left;font-weight:700;\"\u003eVertiv Liebert CRV\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFormat\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eIn row cabinet 300, 400 or 600 mm wide, 1,950 mm high, sitting directly between racks\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eIn row cabinet in comparable narrow widths, also designed to sit in the rack line\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCapacity band\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11 kW to 58 kW total\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eBroadly comparable in row band, published by model and rating condition\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eZone control\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eThree horizontal zones, up to five independently variable EC fans, six temperature sensors\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eVariable speed EC fans with multiple sensors; zoning behaviour differs by model and control version\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eChilled water redundancy\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eCW2 connects one unit to two independent chilled water circuits\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eDual circuit options available on selected configurations; confirm per model\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFree Cooling\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eGES hybrid with Indirect Dynamic Free Cooling, 21.5 kW and 30.9 kW Free Cooling ratings\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eEconomiser strategies generally handled at the chilled water plant rather than in the in row unit\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eService access\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eFront and rear doors, pivoting electrical box, aisle side filter change\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;border-bottom:1px solid #e3e3e3;\"\u003eFront and rear access on most configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:11px 16px;font-weight:700;border-right:1px solid #e3e3e3;\"\u003eAustralian service\u003c\/th\u003e\n\u003ctd style=\"padding:11px 16px;border-right:1px solid #e3e3e3;\"\u003eIndigi Power and Cooling, national coverage from Brisbane, Sydney and Melbourne\u003c\/td\u003e\n\u003ctd style=\"padding:11px 16px;\"\u003eIndigi also services Vertiv and Liebert equipment. See our \u003ca href=\"\/pages\/liebert-crac-spare-parts-australia-emerson-vertiv-cooling-components\" style=\"color:#d9590c;\"\u003eLiebert spare parts page\u003c\/a\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eInstallation, commissioning and maintenance in Australia\u003c\/h2\u003e\n\u003cp\u003eA CyberRow deployment is a licensed job on two fronts. Electrical work must be carried out by a licensed electrician to AS\/NZS 3000, and any work on the refrigerant circuit of an A, AS, GS or GES unit requires an ARCtick licensed refrigeration technician under the Ozone Protection and Synthetic Greenhouse Gas Management Regulations. Where the installation forms part of a mechanical ventilation system, AS\/NZS 3666 hygiene obligations apply to the air handling components and to the cleaning and inspection regime. Indigi handles all of this in house rather than subcontracting the critical path.\u003c\/p\u003e\n\u003cp\u003eTypical scope covers heat load verification against the actual IT draw rather than nameplate figures, rack by rack load mapping so the number and placement of units is right, air conduction selection to match the containment strategy, chilled water or refrigerant pipe design and dry cooler or condenser siting, rigging into a live aisle, controller configuration, BMS integration over Modbus on the standard RS-485 port, and witness commissioning with documented handover. We measure server inlet temperatures at commissioning and confirm they sit within the ASHRAE TC 9.9 recommended envelope of 18 to 27 degrees Celsius, because that is the number an auditor or a hardware vendor will ask about, not the unit's supply air temperature.\u003c\/p\u003e\n\u003cp\u003eIndicative pricing for server room cooling design and installation runs from $8,000 to $15,000 for small rooms, $25,000 to $45,000 for medium installations and $45,000 to $60,000 plus for large projects. A typical in row retrofit of two to four CyberRow units into an existing row, including pipework and controls integration, usually lands in the medium band. Quoted scope always depends on the site, the pipe run and how much work has to happen out of hours.\u003c\/p\u003e\n\u003cp\u003eOnce running, the unit needs a maintenance regime that reflects continuous duty. The schedule should cover filter condition and replacement, coil cleanliness, condensate management, refrigerant charge and leak checks on DX models, chilled water valve and actuator operation on CW and CW2 models, fan bearing and EC fan health across all five fans, controller alarm history, and verification that the zone sensors are still reading correctly after any rack moves. See our \u003ca href=\"\/pages\/crac-unit-maintenance-services\" style=\"color:#d9590c;\"\u003eCRAC unit maintenance services\u003c\/a\u003e, \u003ca href=\"\/pages\/dx-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eDX CRAC servicing\u003c\/a\u003e and \u003ca href=\"\/pages\/cdw-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCDW CRAC servicing\u003c\/a\u003e pages for how we structure this.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhat is in row cooling and when should you use it?\u003c\/h3\u003e\n\u003cp\u003eIn row cooling places the cooling unit directly in the rack line, between the server cabinets, instead of at the perimeter of the room. It shortens the air path so cold air reaches the server inlet before it mixes with hot exhaust air, and it lets the unit measure and respond to temperatures at the racks themselves. Use it where rack densities are high, where a hot spot has appeared that perimeter units cannot resolve, or where there is no raised floor to distribute air through.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eHow many server racks can one STULZ CyberRow unit cool?\u003c\/h3\u003e\n\u003cp\u003eSTULZ rates each CyberRow unit at up to six server cabinets. The actual number depends on the load per cabinet, the containment arrangement and the air conduction option selected. A row of low density cabinets at 4 kW each is a very different selection to three cabinets carrying 15 kW of GPU compute, so the unit count should always come from a rack by rack load map rather than a rule of thumb.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eDoes the STULZ CyberRow need a raised floor?\u003c\/h3\u003e\n\u003cp\u003eNo. The CyberRow is suitable for data centres and server rooms with or without a raised floor, because air is distributed horizontally along the row rather than through a floor void. Water connection openings are pre cut as standard at both the top and the bottom of the cabinet, so overhead and under floor reticulation are both supported without site fabrication.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhat cooling capacity does the STULZ CyberRow deliver?\u003c\/h3\u003e\n\u003cp\u003eThe range covers 11 kW to 58 kW of total cooling capacity with airflow from 3,200 to 11,200 cubic metres per hour, across six sizes in three widths of 300, 400 and 600 mm and two depths. The DX and hybrid Free Cooling models run from 11.4 kW on the CRS\/CRL 101 A to 37 kW on the CRS\/CRL 361, measured at return air of 35 degrees Celsius and 25 per cent relative humidity. The top of the range is reached on CW and CW2 chilled water configurations.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eHow does the CyberRow work with hot aisle and cold aisle containment?\u003c\/h3\u003e\n\u003cp\u003eUnits with a frontal air outlet are used for cold aisle containment and are positioned at an offset to one another so the whole cold aisle is supplied rather than only the neighbouring racks. Units with side air conduction are used for hot aisle containment, expelling cold air sideways for uniform distribution along the length of the aisle. Where no physical containment exists, the optimised horizontal air pattern still creates a virtual containment around the racks the unit serves.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWhat happens if a fan fails in a STULZ CyberRow?\u003c\/h3\u003e\n\u003cp\u003eIf one fan fails, the remaining fans automatically increase speed to maintain cooling capacity, so a single fan fault does not become a thermal event while a technician is dispatched. The STULZ controller monitors and reports all faults, and alarms can be passed to a building management system through the standard RS-485 serial port using Modbus or STULZ protocols.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:24px 0 8px 0;\"\u003eWho supplies and services STULZ in row cooling units in Australia?\u003c\/h3\u003e\n\u003cp\u003eIndigi Power and Cooling supplies, installs, commissions and maintains STULZ CyberRow in row cooling units across Australia from hubs in Brisbane, Sydney and Melbourne. Electrical work is carried out to AS\/NZS 3000 and all refrigerant work by ARCtick licensed technicians. We also service existing in row and perimeter cooling units installed by others, including Vertiv and Liebert equipment.\u003c\/p\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eWhere we install and service\u003c\/h2\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:16px;margin-bottom:32px;\"\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/ups-battery-crac-maintenance-brisbane\" style=\"color:#111111;text-decoration:none;\"\u003eBrisbane and QLD\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eBrisbane CBD, Woolloongabba, Eight Mile Plains, Port of Brisbane, Gold Coast, Sunshine Coast, Ipswich, Townsville, Cairns\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eNational HQ at Tingalpa. Fastest response for in row retrofits and hot spot remediation in South East Queensland.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/ups-data-centre-cooling-maintenance-sydney\" style=\"color:#111111;text-decoration:none;\"\u003eSydney and NSW\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eSydney CBD, Parramatta, North Ryde, Macquarie Park, Western Sydney, Newcastle, Wollongong, Canberra (ACT)\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eWhere the highest rack densities in the country sit. Most CW and CW2 chilled water in row selections come from this market.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003e\u003ca href=\"\/pages\/critical-power-crac-maintenance-melbourne\" style=\"color:#111111;text-decoration:none;\"\u003eMelbourne and VIC\u003c\/a\u003e\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eMelbourne CBD, Port Melbourne, Docklands, Dandenong, Tullamarine, Geelong, Ballarat, regional Victoria\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eThe strongest Free Cooling business case on the mainland. GES hybrid selections repay their premium fastest here.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003ePerth and WA\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003ePerth CBD, Fremantle, Kalgoorlie, Pilbara, regional WA\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eResources sector rooms with high ambient design conditions. Condenser and dry cooler sizing is the critical variable.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003eAdelaide and SA\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eAdelaide CBD, Port Adelaide, Salisbury, Mount Gambier, Whyalla, regional SA\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eGood Free Cooling hours through the cooler months, served from the Melbourne hub.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"border:1px solid #e3e3e3;border-radius:8px;padding:18px 20px;background-color:#fafafa;\"\u003e\n    \u003ch3 style=\"font-size:19px;font-weight:800;color:#111111;margin:0 0 6px 0;\"\u003eDarwin and NT\u003c\/h3\u003e\n    \u003cp style=\"font-size:15px;margin:0 0 5px 0;color:#555;\"\u003eDarwin CBD, Palmerston, Katherine, Alice Springs, remote NT sites\u003c\/p\u003e\n    \u003cp style=\"font-size:14px;margin:0;color:#888888;\"\u003eHigh humidity design conditions. Latent load and condensate handling need specific attention at selection stage.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color:#111111;border-radius:8px;padding:16px 20px;margin-bottom:32px;\"\u003e\n  \u003cp style=\"color:#ffffff;margin:0;\"\u003e\n    \u003cstrong\u003eWestern Australia, Tasmania and Pacific Islands:\u003c\/strong\u003e we schedule CyberRow installation and service visits in planned blocks to keep travel costs down, and we can combine in row cooling work with UPS and battery attendance in a single mobilisation.\n    \u003ca href=\"\/pages\/contact\" style=\"color:#d9590c;\"\u003eContact us to discuss scheduling.\u003c\/a\u003e\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"font-size:22px;font-weight:800;color:#111111;margin:34px 0 16px 0;\"\u003eRelated products and services\u003c\/h2\u003e\n\u003cul style=\"font-size:17px;padding-left:22px;margin-bottom:28px;\"\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-unit-maintenance-services\" style=\"color:#d9590c;\"\u003eCRAC unit maintenance services Australia\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/chw-crac-maintenance-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eCHW CRAC maintenance for chilled water in row and perimeter units\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/dx-crac-servicing-brisbane-sydney-melbourne\" style=\"color:#d9590c;\"\u003eDX CRAC servicing across Brisbane, Sydney and Melbourne\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-installation-commissioning-australia\" style=\"color:#d9590c;\"\u003eCRAC installation and commissioning\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-cooling-australia\" style=\"color:#d9590c;\"\u003eServer room cooling Australia\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-heat-load-calculator\" style=\"color:#d9590c;\"\u003eServer room heat load calculator\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/crac-topology-selector-australia\" style=\"color:#d9590c;\"\u003eCRAC topology selector: DX, CHW or CDW\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli style=\"margin-bottom:8px;\"\u003e\u003ca href=\"\/pages\/server-room-ups-cooling-australia\" style=\"color:#d9590c;\"\u003eServer room UPS and cooling packages\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;\" role=\"presentation\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"background-color:#111111;border-radius:10px;padding:28px 24px;text-align:center;\"\u003e\n      \u003cp style=\"color:#ffffff;font-size:21px;font-weight:800;margin-top:0;margin-bottom:10px;\"\u003eGet a CyberRow in row cooling selection for your racks\u003c\/p\u003e\n      \u003cp style=\"color:#cfcfcf;font-size:16px;margin-top:0;margin-bottom:18px;\"\u003eSend us your rack layout, the load per cabinet, your containment arrangement and whether chilled water is available, and we will come back with a unit count, an air conduction selection and an installed price. Indigi Power and Cooling is Indigenous and Veteran owned, and registered with Supply Nation and ICN Gateway.\u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background-color:#d9590c;color:#ffffff;font-weight:700;text-decoration:none;padding:12px 28px;border-radius:6px;\"\u003eContact Indigi Power and Cooling\u003c\/a\u003e\n    \u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Product\",\"name\":\"STULZ CyberRow In Row Cooling Units Australia\",\"description\":\"STULZ CyberRow in row cooling units for high density server racks, 11 kW to 58 kW total cooling capacity and 3,200 to 11,200 cubic metres per hour airflow. Each unit cools up to six server cabinets, suits data centres with or without a raised floor, and supports hot aisle and cold aisle containment. Supplied, installed and serviced across Australia by Indigi Power and Cooling.\",\"brand\":{\"@type\":\"Brand\",\"name\":\"STULZ\"},\"category\":\"In Row Rack Cooling for Data Centres\",\"offers\":{\"@type\":\"Offer\",\"availability\":\"https:\/\/schema.org\/InStock\",\"seller\":{\"@type\":\"Organization\",\"name\":\"Indigi Power and Cooling\",\"url\":\"https:\/\/www.indigipc.com.au\",\"telephone\":\"1800046344\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"10\/240 New Cleveland Road\",\"addressLocality\":\"Tingalpa\",\"addressRegion\":\"QLD\",\"postalCode\":\"4173\",\"addressCountry\":\"AU\"}},\"areaServed\":\"AU\"},\"model\":[\"CRS 101 A\",\"CRL 101 A\",\"CRS 211 A\",\"CRL 211 A\",\"CRS 211 AS\",\"CRL 211 AS\",\"CRS 251 A\",\"CRL 251 A\",\"CRS 251 AS\",\"CRL 251 AS\",\"CRS 251 GS\",\"CRL 251 GS\",\"CRS 361 A\",\"CRL 361 A\",\"CRS 361 AS\",\"CRL 361 AS\",\"CRS 361 GS\",\"CRL 361 GS\",\"CRS 251 GES\",\"CRL 251 GES\",\"CRS 361 GES\",\"CRL 361 GES\"],\"additionalProperty\":[{\"@type\":\"PropertyValue\",\"name\":\"Cooling capacity\",\"value\":\"11 kW to 58 kW\"},{\"@type\":\"PropertyValue\",\"name\":\"Airflow volume\",\"value\":\"3,200 to 11,200 m3\/h\"},{\"@type\":\"PropertyValue\",\"name\":\"Height\",\"value\":\"1,950 mm\"},{\"@type\":\"PropertyValue\",\"name\":\"Widths\",\"value\":\"300 mm, 400 mm, 600 mm\"},{\"@type\":\"PropertyValue\",\"name\":\"Racks cooled per unit\",\"value\":\"Up to six server cabinets\"},{\"@type\":\"PropertyValue\",\"name\":\"Cooling systems\",\"value\":\"A\/AS air cooled, GS water cooled, GES hybrid Free Cooling, CW and CW2 chilled water\"},{\"@type\":\"PropertyValue\",\"name\":\"Refrigerants\",\"value\":\"R410A, R134a\"}]}\n\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What is in row cooling and when should you use it?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"In row cooling places the cooling unit directly in the rack line, between the server cabinets, instead of at the perimeter of the room. It shortens the air path so cold air reaches the server inlet before it mixes with hot exhaust air, and it lets the unit measure and respond to temperatures at the racks themselves. Use it where rack densities are high, where a hot spot has appeared that perimeter units cannot resolve, or where there is no raised floor to distribute air through.\"}},\n{\"@type\":\"Question\",\"name\":\"How many server racks can one STULZ CyberRow unit cool?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"STULZ rates each CyberRow unit at up to six server cabinets. The actual number depends on the load per cabinet, the containment arrangement and the air conduction option selected, so the unit count should come from a rack by rack load map rather than a rule of thumb.\"}},\n{\"@type\":\"Question\",\"name\":\"Does the STULZ CyberRow need a raised floor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The CyberRow is suitable for data centres and server rooms with or without a raised floor, because air is distributed horizontally along the row rather than through a floor void. Water connection openings are pre cut as standard at both the top and the bottom of the cabinet, so overhead and under floor reticulation are both supported.\"}},\n{\"@type\":\"Question\",\"name\":\"What cooling capacity does the STULZ CyberRow deliver?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The range covers 11 kW to 58 kW of total cooling capacity with airflow from 3,200 to 11,200 cubic metres per hour, across six sizes in three widths of 300, 400 and 600 mm and two depths. The DX and hybrid Free Cooling models run from 11.4 kW on the CRS\/CRL 101 A to 37 kW on the CRS\/CRL 361 at return air of 35 degrees Celsius and 25 per cent relative humidity. The top of the range is reached on CW and CW2 chilled water configurations.\"}},\n{\"@type\":\"Question\",\"name\":\"How does the CyberRow work with hot aisle and cold aisle containment?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Units with a frontal air outlet are used for cold aisle containment and are positioned at an offset to one another so the whole cold aisle is supplied rather than only the neighbouring racks. Units with side air conduction are used for hot aisle containment, expelling cold air sideways for uniform distribution along the length of the aisle. Where no physical containment exists, the optimised horizontal air pattern still creates a virtual containment around the racks the unit serves.\"}},\n{\"@type\":\"Question\",\"name\":\"What happens if a fan fails in a STULZ CyberRow?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"If one fan fails, the remaining fans automatically increase speed to maintain cooling capacity, so a single fan fault does not become a thermal event while a technician is dispatched. The STULZ controller monitors and reports all faults, and alarms can be passed to a building management system through the standard RS-485 serial port using Modbus or STULZ protocols.\"}},\n{\"@type\":\"Question\",\"name\":\"Who supplies and services STULZ in row cooling units in Australia?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Indigi Power and Cooling supplies, installs, commissions and maintains STULZ CyberRow in row cooling units across Australia from hubs in Brisbane, Sydney and Melbourne. Electrical work is carried out to AS\/NZS 3000 and all refrigerant work by ARCtick licensed technicians. Indigi also services existing in row and perimeter cooling units installed by others, including Vertiv and Liebert equipment.\"}}\n]}\n\u003c\/script\u003e","brand":"STULZ","offers":[{"title":"Default Title","offer_id":52961619870016,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/CyberRow_800x800px.jpg?v=1786195498","url":"https:\/\/www.indigipc.com.au\/products\/stulz-cyberrow-in-row-rack-cooling-australia","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}