{"product_id":"tc-3000-high-temperature-ups-high-temperature","title":"TC-3000 High Temperature UPS| High Temperature UPS","description":"\u003ch2 data-start=\"5952\" data-end=\"6011\" data-section-id=\"zou64h\"\u003eTC-3000 Industrial High Temperature UPS (3000VA \/ 3000W)\u003c\/h2\u003e\n\u003cp data-start=\"6013\" data-end=\"6188\"\u003eThe \u003cstrong data-start=\"6017\" data-end=\"6041\"\u003ePowercom TC-3000 UPS\u003c\/strong\u003e is the largest model in the TC industrial UPS range, providing robust power protection for critical infrastructure requiring higher load capacity.\u003c\/p\u003e\n\u003cp data-start=\"6190\" data-end=\"6307\"\u003eEngineered for demanding environments, the TC-3000 ensures continuous operation even in extreme ambient temperatures. To learn more about \u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/why-high-temperature-ups-systems-are-critical-for-industrial-infrastructure\" title=\"Why High Temperature UPS Systems Are Critical for Industrial Infrastructure\" rel=\"noopener\" target=\"_blank\"\u003ewhy high temp UPS systems are critical for industrial infrastructure\u003c\/a\u003e read here.\u003c\/p\u003e\n\u003ch3 data-start=\"6309\" data-end=\"6325\" data-section-id=\"1iz91iu\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"6327\" data-end=\"6558\"\u003e\n\u003cli data-start=\"6327\" data-end=\"6369\" data-section-id=\"1bvkkle\"\u003e\n\u003cp data-start=\"6329\" data-end=\"6369\"\u003e3000VA \/ 3000W industrial UPS capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6370\" data-end=\"6422\" data-section-id=\"3pamg3\"\u003e\n\u003cp data-start=\"6372\" data-end=\"6422\"\u003eExtreme temperature operation \u003cstrong data-start=\"6402\" data-end=\"6420\"\u003e–37°C to +74°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6423\" data-end=\"6448\" data-section-id=\"1m6kqdt\"\u003e\n\u003cp data-start=\"6425\" data-end=\"6448\"\u003ePure sine wave output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6449\" data-end=\"6490\" data-section-id=\"ytv1wv\"\u003e\n\u003cp data-start=\"6451\" data-end=\"6490\"\u003eBuilt-in Automatic Voltage Regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6491\" data-end=\"6518\" data-section-id=\"1krrbo5\"\u003e\n\u003cp data-start=\"6493\" data-end=\"6518\"\u003eGenerator compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6519\" data-end=\"6558\" data-section-id=\"1nmjgtt\"\u003e\n\u003cp data-start=\"6521\" data-end=\"6558\"\u003eAdvanced communication and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"6560\" data-end=\"6588\" data-section-id=\"nucr17\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"6590\" data-end=\"6840\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"6590\" data-end=\"6617\"\u003e\n\u003ctr data-start=\"6590\" data-end=\"6617\"\u003e\n\u003cth data-start=\"6590\" data-end=\"6606\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"6606\" data-end=\"6617\" data-col-size=\"sm\" class=\"\"\u003eTC-3000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"6628\" data-end=\"6840\"\u003e\n\u003ctr data-start=\"6628\" data-end=\"6659\"\u003e\n\u003ctd data-start=\"6628\" data-end=\"6639\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-start=\"6639\" data-end=\"6659\" data-col-size=\"sm\"\u003e3000 VA \/ 3000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6660\" data-end=\"6688\"\u003e\n\u003ctd data-start=\"6660\" data-end=\"6678\" data-col-size=\"sm\"\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd data-start=\"6678\" data-end=\"6688\" data-col-size=\"sm\"\u003e48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6689\" data-end=\"6725\"\u003e\n\u003ctd data-start=\"6689\" data-end=\"6707\" data-col-size=\"sm\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd data-start=\"6707\" data-end=\"6725\" data-col-size=\"sm\"\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6726\" data-end=\"6751\"\u003e\n\u003ctd data-start=\"6726\" data-end=\"6742\" data-col-size=\"sm\"\u003eTransfer Time\u003c\/td\u003e\n\u003ctd data-start=\"6742\" data-end=\"6751\" data-col-size=\"sm\"\u003e12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6752\" data-end=\"6794\"\u003e\n\u003ctd data-start=\"6752\" data-end=\"6776\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"6776\" data-end=\"6794\" data-col-size=\"sm\"\u003e–37°C to +74°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6795\" data-end=\"6840\"\u003e\n\u003ctd data-start=\"6795\" data-end=\"6811\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-start=\"6811\" data-end=\"6840\" data-col-size=\"sm\"\u003eRS232, USB, Optional SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-start=\"6842\" data-end=\"6858\" data-section-id=\"wggvqn\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-start=\"6842\" data-end=\"6858\" data-section-id=\"wggvqn\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"6860\" data-end=\"6981\"\u003e\n\u003cli data-start=\"6860\" data-end=\"6886\" data-section-id=\"1lzibfa\"\u003e\n\u003cp data-start=\"6862\" data-end=\"6886\"\u003etelecom infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6887\" data-end=\"6911\" data-section-id=\"6sc8sl\"\u003e\n\u003cp data-start=\"6889\" data-end=\"6911\"\u003eremote power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6912\" data-end=\"6947\" data-section-id=\"1wp5aca\"\u003e\n\u003cp data-start=\"6914\" data-end=\"6947\"\u003eindustrial automation equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6948\" data-end=\"6981\" data-section-id=\"1g5vb3k\"\u003e\n\u003cp data-start=\"6950\" data-end=\"6981\"\u003eutilities and transport systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2159\" data-end=\"2294\"\u003e\u003ca href=\"https:\/\/www.upspowercom.com\/pcm-img\/UPS-TC\/Catalog.pdf\" title=\"product brochure\" rel=\"noopener\" target=\"_blank\"\u003eProduct Brochure:\u003c\/a\u003e\u003c\/p\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51597448839488,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/TC2500_TC3000.png?v=1772759064","url":"https:\/\/www.indigipc.com.au\/products\/tc-3000-high-temperature-ups-high-temperature","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}