{"product_id":"tc-650-high-temperature-ups-high-temperature-ups","title":"TC-650 High Temperature UPS| High Temperature UPS","description":"\u003ch2 data-section-id=\"vrafip\" data-start=\"401\" data-end=\"457\"\u003eTC-650 High Temperature Industrial UPS (650VA \/ 650W)\u003c\/h2\u003e\n\u003cp data-start=\"459\" data-end=\"652\"\u003eThe \u003cstrong data-start=\"463\" data-end=\"503\"\u003ePowercom TC-650 High Temperature UPS\u003c\/strong\u003e is an industrial-grade uninterruptible power supply designed for harsh operating environments where traditional UPS systems cannot operate reliably.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"993\"\u003eEngineered for outdoor infrastructure and industrial applications, the TC-650 delivers dependable backup power with a \u003cstrong data-start=\"772\" data-end=\"845\"\u003ewide operating temperature range from –37°C to +74°C without derating\u003c\/strong\u003e, making it ideal for remote installations and equipment cabinets exposed to extreme environmental conditions. To learn more about \u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/why-high-temperature-ups-systems-are-critical-for-industrial-infrastructure\" title=\"Why High Temperature UPS Systems Are Critical for Industrial Infrastructure\" rel=\"noopener\" target=\"_blank\"\u003ewhy high temp UPS systems are critical for industrial infrastructure\u003c\/a\u003e read here.\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"993\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"relative inline-flex items-center\"\u003e\u003cbutton class=\"ms-1 flex h-[25px] text-[10px] leading-[13px] rounded-xl corner-superellipse\/1.1 items-center justify-center gap-1 px-2 relative text-token-text-secondary! hover:text-token-text-primary! hover:bg-token-bg-secondary dark:bg-token-main-surface-secondary dark:hover:bg-token-bg-secondary bg-[#f4f4f4]\"\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/span\u003eKey Features\u003c\/p\u003e\n\u003cul data-start=\"1013\" data-end=\"1373\"\u003e\n\u003cli data-section-id=\"r8cu24\" data-start=\"1013\" data-end=\"1044\"\u003e\n\u003cp data-start=\"1015\" data-end=\"1044\"\u003e650VA \/ 650W power capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"elbfi5\" data-start=\"1045\" data-end=\"1100\"\u003e\n\u003cp data-start=\"1047\" data-end=\"1100\"\u003eWide operating temperature range \u003cstrong data-start=\"1080\" data-end=\"1098\"\u003e–37°C to +74°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nkckuk\" data-start=\"1101\" data-end=\"1150\"\u003e\n\u003cp data-start=\"1103\" data-end=\"1150\"\u003ePure sine wave output for sensitive equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tekq3v\" data-start=\"1151\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1198\"\u003eBuilt-in Automatic Voltage Regulation (AVR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1024j6h\" data-start=\"1199\" data-end=\"1236\"\u003e\n\u003cp data-start=\"1201\" data-end=\"1236\"\u003eGenerator compatible input design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10z5avk\" data-start=\"1237\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1239\" data-end=\"1295\"\u003eProgrammable dry contacts for external control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9pgbu6\" data-start=\"1296\" data-end=\"1339\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1339\"\u003eRS-232 and USB communication interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ou4rf2\" data-start=\"1340\" data-end=\"1373\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1373\"\u003eOptional SNMP remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1375\" data-end=\"1403\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1405\" data-end=\"1722\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1405\" data-end=\"1431\"\u003e\n\u003ctr data-start=\"1405\" data-end=\"1431\"\u003e\n\u003cth data-start=\"1405\" data-end=\"1421\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1421\" data-end=\"1431\" data-col-size=\"sm\" class=\"\"\u003eTC-650\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1442\" data-end=\"1722\"\u003e\n\u003ctr data-start=\"1442\" data-end=\"1471\"\u003e\n\u003ctd data-start=\"1442\" data-end=\"1453\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1453\" data-end=\"1471\"\u003e650 VA \/ 650 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1472\" data-end=\"1522\"\u003e\n\u003ctd data-start=\"1472\" data-end=\"1488\" data-col-size=\"sm\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1488\" data-end=\"1522\"\u003e120VAC ±25% or 220–240VAC ±25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1523\" data-end=\"1559\"\u003e\n\u003ctd data-start=\"1523\" data-end=\"1541\" data-col-size=\"sm\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1541\" data-end=\"1559\"\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1560\" data-end=\"1585\"\u003e\n\u003ctd data-start=\"1560\" data-end=\"1576\" data-col-size=\"sm\"\u003eTransfer Time\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1576\" data-end=\"1585\"\u003e12 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1586\" data-end=\"1614\"\u003e\n\u003ctd data-start=\"1586\" data-end=\"1604\" data-col-size=\"sm\"\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1604\" data-end=\"1614\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1615\" data-end=\"1657\"\u003e\n\u003ctd data-start=\"1615\" data-end=\"1639\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1639\" data-end=\"1657\"\u003e–37°C to +74°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1658\" data-end=\"1703\"\u003e\n\u003ctd data-start=\"1658\" data-end=\"1674\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1674\" data-end=\"1703\"\u003eRS232, USB, Optional SNMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1704\" data-end=\"1722\"\u003e\n\u003ctd data-start=\"1704\" data-end=\"1712\" data-col-size=\"sm\"\u003eNoise\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"1712\" data-end=\"1722\"\u003e\u0026lt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"1724\" data-end=\"1748\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-section-id=\"ucz99x\" data-start=\"1724\" data-end=\"1748\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cp data-start=\"1750\" data-end=\"1813\"\u003eThe TC-650 is ideal for smaller infrastructure loads including:\u003c\/p\u003e\n\u003cul data-start=\"1815\" data-end=\"1978\"\u003e\n\u003cli data-section-id=\"22s3em\" data-start=\"1815\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1817\" data-end=\"1845\"\u003etelecom equipment cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ypv451\" data-start=\"1846\" data-end=\"1879\"\u003e\n\u003cp data-start=\"1848\" data-end=\"1879\"\u003eindustrial monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uj7ool\" data-start=\"1880\" data-end=\"1924\"\u003e\n\u003cp data-start=\"1882\" data-end=\"1924\"\u003esecurity and surveillance infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2xjqgh\" data-start=\"1925\" data-end=\"1953\"\u003e\n\u003cp data-start=\"1927\" data-end=\"1953\"\u003etraffic signal equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mhicif\" data-start=\"1954\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1956\" data-end=\"1978\"\u003eremote sensor networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1xxf4ds\" data-start=\"1980\" data-end=\"1987\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-start=\"1989\" data-end=\"2157\"\u003e\u003cstrong data-start=\"1989\" data-end=\"2025\"\u003eCan the TC-650 operate outdoors?\u003c\/strong\u003e\u003cbr data-start=\"2025\" data-end=\"2028\"\u003eYes. The UPS is designed for harsh environments and can operate in extreme temperatures when installed in appropriate enclosures.\u003c\/p\u003e\n\u003cp data-start=\"2159\" data-end=\"2294\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2203\"\u003eDoes the TC-650 support generator power?\u003c\/strong\u003e\u003cbr data-start=\"2203\" data-end=\"2206\"\u003eYes. Generator mode allows the UPS to tolerate wider voltage and frequency fluctuations.\u003c\/p\u003e\n\u003cp data-start=\"2159\" data-end=\"2294\"\u003e\u003ca href=\"https:\/\/www.upspowercom.com\/pcm-img\/UPS-TC\/Catalog.pdf\" title=\"product brochure\" rel=\"noopener\" target=\"_blank\"\u003eProduct Brochure:\u003c\/a\u003e\u003c\/p\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51597408502080,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/TC650HightempUPS.png?v=1772759647","url":"https:\/\/www.indigipc.com.au\/products\/tc-650-high-temperature-ups-high-temperature-ups","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}