{"product_id":"uqd-quick-disconnect-coupling-male-orb-iso-11926-3","title":"UQD Quick Disconnect Coupling, Male ORB ISO 11926-3","description":"\u003cdiv style=\"box-sizing:border-box;max-width:960px;margin:0 auto;font-family:Arial,Helvetica,sans-serif;font-size:17px;line-height:1.6;color:#222222;\"\u003e\n\u003cdiv style=\"background-color:#fafafa;border-left:4px solid #d9590c;border-radius:6px;padding:16px 20px;margin-bottom:26px;\"\u003e\u003cp style=\"margin:0;font-size:19px;\"\u003e\u003cstrong\u003eThis is a flat-face, push-to-connect stainless steel quick disconnect coupling for data centre liquid cooling loops, in the Open Compute Project UQD sizes UQD02, UQD04 and UQD06, with a male O-ring boss thread to ISO 11926-3.\u003c\/strong\u003e Manufactured by Alfagomma and supplied by Indigi Power and Cooling, who buy direct. EPDM seals matched to the coolant hose, stainless steel body, and every unit helium leak tested rather than batch sampled.\u003c\/p\u003e\u003c\/div\u003e\n\u003cp\u003eCouplings with an O-ring boss thread in the UNF series. Common on North American hardware and on most coolant distribution units sold into Australia, including the Vertiv range.\u003c\/p\u003e\n\u003ch2 style=\"font-size:24px;font-weight:800;color:#111111;margin:32px 0 14px 0;\"\u003ePart numbers and dimensions\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x:auto;border-radius:8px;border:1px solid #2a2a2a;margin-bottom:26px;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;line-height:1.45;\"\u003e\n\u003ccaption style=\"caption-side:top;text-align:left;font-size:13px;color:#666666;padding:0 0 8px 2px;\"\u003eTable: UQD Quick Disconnect Coupling, Male ORB ISO 11926-3, part numbers and dimensions by UQD size.\u003c\/caption\u003e\n\u003cthead\u003e\u003ctr style=\"background-color:#111111;color:#ffffff;\"\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eUQD size\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003ePart number\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eThread\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eE\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eF\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eG\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eH\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eJ\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding:12px 14px;text-align:left;font-weight:700;border-right:1px solid #333;\"\u003eHex\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUQD02\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHZ213010-040400\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e7\/16-20 UNF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e17.3 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e29.3 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e9.1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e13.5 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e6.6 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e14.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ececec;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUQD04\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHZ213010-060600\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e9\/16-18 UNF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e19.6 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e38.2 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e10.6 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.1 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e17.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#fafafa;\"\u003e\n\u003cth scope=\"row\" style=\"padding:10px 14px;font-weight:700;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eUQD06\u003c\/th\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003eHZ213010-080800\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e3\/4-16 UNF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e24.6 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e41.8 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.0 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e11.0 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e14.3 mm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border-right:1px solid #e3e3e3;border-bottom:1px solid #e3e3e3;\"\u003e22.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThread sizes are 7\/16-20 UNF for UQD02, 9\/16-18 UNF for UQD04 and 3\/4-16 UNF for UQD06. O-ring boss ports seal on the face rather than the thread, so O-ring condition matters more than thread torque.\u003c\/p\u003e\n\u003ch2 style=\"font-size:24px;font-weight:800;color:#111111;margin:32px 0 14px 0;\"\u003eWhy these details matter\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFlat face\u003c\/strong\u003e matters for two reasons: very little coolant is lost on disconnect, and no air is drawn in on reconnection. Air in a technology cooling loop causes pump cavitation, hot spots inside cold plates and corrosion. It is also simply easier to wipe clean before mating, which keeps particulate out.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHelium leak testing\u003c\/strong\u003e finds leak paths that water will not move through fast enough to register on a pressure decay test. On a loop at 20 bar through hundreds of connection points, the leak that only appears after six months in service is exactly the one worth catching at the factory. Every unit is tested, not a batch sample.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEPDM seals\u003c\/strong\u003e are matched to the EPDM coolant hose tube and to propylene glycol coolants. Do not mix seal materials across one loop.\u003c\/p\u003e\n\u003ch2 style=\"font-size:24px;font-weight:800;color:#111111;margin:32px 0 14px 0;\"\u003eSpecifying across a site\u003c\/h2\u003e\n\u003cp\u003eKeep \u003cstrong\u003eone coupling family and one seal material\u003c\/strong\u003e across the whole site. Mixed coupling families on a single row is the most common liquid cooling problem we are called to, and it cannot be fixed without replacing hardware. The binding coolant chemistry specification normally comes from your server or cold plate vendor rather than the CDU vendor, and operating outside it can void hardware warranty.\u003c\/p\u003e\n\u003ch2 style=\"font-size:24px;font-weight:800;color:#111111;margin:32px 0 14px 0;\"\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:22px 0 8px 0;\"\u003eWhat does UQD mean, and will these mate with another manufacturer?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eUQD stands for universal quick disconnect. The sizing and dimensional envelope come from the Open Compute Project specification, which is why several manufacturers all offer UQD02, UQD04 and UQD06 that interchange dimensionally. They will physically mate. They do not necessarily perform identically, because flow coefficient, seal material and spill volume still vary, so standardise on one family across a site and record the part numbers.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:22px 0 8px 0;\"\u003eWhich size should I use?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eSize to the flow the node actually needs, then match the hose to the coupling rather than the other way round. As a guide, UQD02 suits lower flow nodes, instrumentation branches and bleed lines; UQD04 is the common size for single-socket and mid-range direct-to-chip nodes; UQD06 suits high flow and multi-socket accelerated servers.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:22px 0 8px 0;\"\u003eCan these be disconnected while the loop is running?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eFlat-face quick disconnects are designed to be connected and disconnected in service with minimal spill, which is what allows a rack to be worked on without draining the loop. Follow your own isolation procedure and the server vendor instructions. Where a genuinely zero-spill disconnect is required we can quote dry-break couplings instead.\u003c\/p\u003e\n\u003ch3 style=\"font-size:19px;font-weight:700;color:#111111;margin:22px 0 8px 0;\"\u003eWhy is there no price shown?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 14px 0;\"\u003eQuantity and configuration change the number, and these are normally quoted as part of an assembly list rather than bought singly. Send a rack elevation or a parts list and we will price it.\u003c\/p\u003e\n\u003ch2 style=\"font-size:24px;font-weight:800;color:#111111;margin:32px 0 14px 0;\"\u003eRelated\u003c\/h2\u003e\n\u003cul style=\"padding-left:22px;margin-bottom:26px;\"\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003ca href=\"\/collections\/data-centre-liquid-cooling-hose-fittings\" style=\"color:#d9590c;\"\u003eAll liquid cooling hose and fittings\u003c\/a\u003e: the full connection layer\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003ca href=\"\/collections\/liquid-cooling-solutions\" style=\"color:#d9590c;\"\u003eLiquid cooling solutions\u003c\/a\u003e: CDUs, rear door and immersion equipment\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003ca href=\"\/pages\/data-centre-liquid-cooling-australia\" style=\"color:#d9590c;\"\u003eInstallation and maintenance\u003c\/a\u003e: pipework, flush, fill and commissioning\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003ca href=\"\/pages\/dcim-data-centre-monitoring-australia\" style=\"color:#d9590c;\"\u003eDCIM and monitoring\u003c\/a\u003e: where leak and flow alarms should land\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable role=\"presentation\" style=\"width:100%;border-collapse:collapse;\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"background-color:#111111;border-radius:10px;padding:26px 22px;text-align:center;\"\u003e\n\u003cp style=\"color:#ffffff;font-size:20px;font-weight:800;margin:0 0 10px 0;\"\u003eQuoted against your rack elevation\u003c\/p\u003e\n\u003cp style=\"color:#cfcfcf;font-size:16px;margin:0 0 18px 0;\"\u003eSend the rack layout, the cold plate port types and the flow per node and we will come back with sizes, assembly lengths, part numbers and an installed price. Indigi Power and Cooling buys these components direct, and is Indigenous and Veteran owned, Supply Nation and ICN Gateway registered.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background-color:#d9590c;color:#ffffff;font-weight:700;text-decoration:none;padding:12px 26px;border-radius:6px;\"\u003eRequest a quote\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"Product\", \"name\": \"UQD Quick Disconnect Coupling, Male ORB ISO 11926-3\", \"description\": \"Flat-face stainless steel UQD quick disconnect coupling for data centre liquid cooling, male O-ring boss thread to ISO 11926-3, sizes UQD02 to UQD06, EPDM seals, helium leak tested.\", \"brand\": {\"@type\": \"Brand\", \"name\": \"Alfagomma\"}, \"manufacturer\": {\"@type\": \"Organization\", \"name\": \"Alfagomma\"}, \"model\": [\"HZ213010-040400\", \"HZ213010-060600\", \"HZ213010-080800\"], \"url\": \"https:\/\/www.indigipc.com.au\/products\/uqd-quick-disconnect-coupling-male-orb-iso-11926-3\", \"seller\": {\"@type\": \"Organization\", \"name\": \"Indigi Power and Cooling\", \"url\": \"https:\/\/www.indigipc.com.au\", \"telephone\": \"1800046344\"}}\u003c\/script\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"BreadcrumbList\", \"itemListElement\": [{\"@type\": \"ListItem\", \"position\": 1, \"name\": \"Home\", \"item\": \"https:\/\/www.indigipc.com.au\"}, {\"@type\": \"ListItem\", \"position\": 2, \"name\": \"Liquid cooling hose and fittings\", \"item\": \"https:\/\/www.indigipc.com.au\/collections\/data-centre-liquid-cooling-hose-fittings\"}, {\"@type\": \"ListItem\", \"position\": 3, \"name\": \"UQD Quick Disconnect Coupling, Male ORB ISO 11926-3\", \"item\": \"https:\/\/www.indigipc.com.au\/products\/uqd-quick-disconnect-coupling-male-orb-iso-11926-3\"}]}\u003c\/script\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"UQD02 (7\/16-20 UNF)","offer_id":68328331772224,"sku":"HZ213010-040400","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"UQD04 (9\/16-18 UNF)","offer_id":68328331804992,"sku":"HZ213010-060600","price":0.0,"currency_code":"AUD","in_stock":true},{"title":"UQD06 (3\/4-16 UNF)","offer_id":68328331837760,"sku":"HZ213010-080800","price":0.0,"currency_code":"AUD","in_stock":true}],"url":"https:\/\/www.indigipc.com.au\/products\/uqd-quick-disconnect-coupling-male-orb-iso-11926-3","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}