{"product_id":"vertiv™-coolcenter-immersion-cooling-system","title":"Vertiv™ CoolCenter Immersion Cooling System","description":"\u003cp\u003e\u003cspan\u003eThe Vertiv™ CoolCenter Immersion is a cooling system that addresses heat directly at the source as IT equipment and heat-generating components are fully submerged in a non-conductive fluid. The heat dissipated is connected to the building's re-cooling system with the associated Coolant Distribution Unit. Designed for high-performance servers in data centers, it provides optimal performance while minimizing operational costs. With multiple system architectures to choose from, select the immersion cooling solution to fit your business needs and growth.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"list-bullets-component_title-redesign\"\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"key-benefits key-benefits-list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMPROVED COOLING EFFICIENCY:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIts immersion cooling technology ensures 100% heat dissipation, enabling your hardware to operate at peak performance levels more consistently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEXTENDED EQUIPMENT LIFESPAN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy immersing your hardware in a non-conductive fluid, Vertiv CoolCenter Immersion eliminates the risks associated with dust, humidity, and temperature fluctuations, prolonging the lifespan of your mission critical equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY SAVINGS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExperience significant reductions in energy consumption with maximized energy efficiency, leading to lower operational costs and a reduced carbon footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSPACE OPTIMIZATION:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact and scalable design allows for higher density deployments, optimizing your infrastructure without compromising performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQUIET OPERATION:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEliminate the noise pollution typically associated with the fans used in traditional cooling systems, enhancing the comfort of your data center personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"list-inline-title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"list-inline-title\"\u003e\u003cstrong\u003eBest Suited For:\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eBanking, Financial and Insurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eBroadcast and Entertainment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eData Center\/Colocation\/Hosting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eEducation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eGovernment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMilitary, Defense, Aerospace and Missile\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional Services\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eTelecom\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Vertiv™ CoolCenter Immersion Cooling system utilizes a liquid cooling method in which servers and other rack components are submerged in a thermally conductive dielectric liquid or fluid within a sealed tank. This liquid, known for its thermal transfer properties, absorbs heat from IT equipment for efficient HPC cooling, lowering energy consumption and operating costs. It has compact, modular and self-contained design that allows higher density deployments. It significantly reduces noise since server fans are not required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"text-center xx-thick\"\u003eBenefits\u003c\/h3\u003e\n\u003cdiv class=\"row same-height-presentation-component\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-6 col-lg-6 same-height-target\"\u003e\n\u003cdiv class=\"presentation-content benefits-list vertical-align\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e100% HEAT DISSIPATION:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Vertiv™ CoolCenter Immersion is designed to­ capture 100% of heat from high-density processing chips and servers, enabling high performance computing, machine learning, and ­AI ­applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHIGH COOLING CAPACITY:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 240kW per immersion cooling system (tank + CDU), it addresses the need for highly efficient cooling system which can drive the cooling system temperature to the max.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHIGH COOLING, HIGH SAVINGS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt requires low investment costs since it can completely manage high ­heat density by itself.­ Its high cooling system temperature also­ allows for extended free cooling periods, reducing energy consumption and operating costs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEASY OBSERVATION AND MAINTENANCE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEasily view unit operation through swing-type cover with transparent window.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHEAT RECOVERY AND REUSE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt allows direct waste heat utilization with direct heat transfer from the chip to the coolant, usually without a heat sink.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"text-center xx-thick\"\u003e\u003c\/h3\u003e\n\u003ch3 class=\"text-center xx-thick\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv class=\"row same-height-presentation-component\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-pull-6 col-sm-6 col-lg-pull-6 col-lg-6 same-height-target\"\u003e\n\u003cdiv class=\"presentation-content features-list vertical-align\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMULTIPLE CONFIGURATIONS:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is available in Standalone All-in-one system or split CDU and Tank models to meet various deployment needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAUTOMATIC FLOW REGULATING VALVE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllow precise coolant and flow with integrated temperature sensors and variable speed pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDUAL PUMPS AND POWER:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncrease uptime and cooling availability using dual power supply with automatic transfer switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINTELLIGENT OPERATION MONITORING:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt has built-in sensors and leak detection integrated in the CDU and tank for adaptive control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSER-FRIENDLY TOUCHSCREEN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor and control with ease with an integrated 9” color touchscreen display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.vertiv.com\/4905b9\/globalassets\/shared\/vertiv-coolcenter-immersion-br-en-emea-mka4l0ukics-web2.pdf\" target=\"_blank\" rel=\"noopener\"\u003ehttps:\/\/www.vertiv.com\/4905b9\/globalassets\/shared\/vertiv-coolcenter-immersion-br-en-emea-mka4l0ukics-web2.pdf\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51559174144320,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/vertiv-coolcenter-immersion-self-contained-features.webp?v=1771940989","url":"https:\/\/www.indigipc.com.au\/products\/vertiv%e2%84%a2-coolcenter-immersion-cooling-system","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}