{"product_id":"vertiv-ita2-10kva-ups-australia","title":"Vertiv™ Liebert® ITA2 | ITA-10kVA-3 PHASE | Indigi Power \u0026 Cooling","description":"\u003ch2\u003eVertiv Liebert ITA2 10kVA 3 Phase UPS \u003cspan style=\"font-size: 0.875rem;\"\u003e| High Efficiency UPS for Data Centres and Critical Power in Australia\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"342\" data-end=\"514\"\u003eCompact and reliable 10kVA three-phase UPS system for IT infrastructure, edge applications and critical environments across Brisbane, Sydney, Melbourne and Papua New Guinea\u003c\/p\u003e\n\u003cp data-start=\"342\" data-end=\"514\"\u003e\u003cspan\u003eTo see more information regarding this model checkout the \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"ITA2 Brochure\" href=\"https:\/\/www.vertiv.com\/493193\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/vertiv-liebert-ita2-5kva---40kva\/liebert-ita2-5-40kva-br-en-ap-1222.pdf\" target=\"_blank\"\u003eBROCHURE\u003c\/a\u003e\u003cspan\u003e \u0026amp; \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"ITA2 16kVA Installation Manual\" href=\"https:\/\/www.vertiv.com\/492e63\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/vertiv-liebert-ita2-5kva---40kva\/liebert--ita2-5-20kva--um-en_asia-_v1.0.pdf\" target=\"_blank\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-start=\"516\" data-end=\"519\"\u003e\n\u003ch2 data-section-id=\"53drpp\" data-start=\"521\" data-end=\"542\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"544\" data-end=\"780\"\u003eThe \u003cstrong data-start=\"548\" data-end=\"623\"\u003eVertiv Liebert ITA2 10kVA UPS (ITA-10k00ALA102P00 \/ ITA-10k00AEA102P00)\u003c\/strong\u003e is a compact, high-performance \u003cstrong data-start=\"655\" data-end=\"694\"\u003eonline double conversion UPS system\u003c\/strong\u003e designed to deliver \u003cstrong data-start=\"715\" data-end=\"753\"\u003eclean, stable and continuous power\u003c\/strong\u003e for critical applications.\u003c\/p\u003e\n\u003cp data-start=\"782\" data-end=\"1035\"\u003eBuilt with flexibility in mind, this UPS supports \u003cstrong data-start=\"832\" data-end=\"870\"\u003erackmount and tower configurations\u003c\/strong\u003e, scalable battery runtimes and intelligent monitoring, making it ideal for \u003cstrong data-start=\"946\" data-end=\"1034\"\u003edata centres, server rooms, network closets, automation systems and edge deployments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1037\" data-end=\"1218\"\u003eWith \u003cstrong data-start=\"1042\" data-end=\"1111\"\u003eunity power factor, high efficiency and advanced control features\u003c\/strong\u003e, the ITA2 ensures maximum uptime while reducing operational costs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1220\" data-end=\"1223\"\u003e\n\u003ch2 data-section-id=\"8k5xne\" data-start=\"1225\" data-end=\"1255\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1hf9xth\" data-start=\"1257\" data-end=\"1306\"\u003eHigh Efficiency and Reduced Operating Costs\u003c\/h3\u003e\n\u003cul data-start=\"1307\" data-end=\"1492\"\u003e\n\u003cli data-section-id=\"1r78qft\" data-start=\"1307\" data-end=\"1363\"\u003e\n\u003cp data-start=\"1309\" data-end=\"1363\"\u003eUp to \u003cstrong data-start=\"1315\" data-end=\"1361\"\u003e96.5% efficiency in double conversion mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p1rksp\" data-start=\"1364\" data-end=\"1404\"\u003e\n\u003cp data-start=\"1366\" data-end=\"1404\"\u003eUp to \u003cstrong data-start=\"1372\" data-end=\"1402\"\u003e99% efficiency in ECO mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4ky6r9\" data-start=\"1405\" data-end=\"1492\"\u003e\n\u003cp data-start=\"1407\" data-end=\"1492\"\u003eReduced energy consumption and cooling demand \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1494\" data-end=\"1497\"\u003e\n\u003ch3 data-section-id=\"1pcbtap\" data-start=\"1499\" data-end=\"1545\"\u003eTrue Online Double Conversion Protection\u003c\/h3\u003e\n\u003cul data-start=\"1546\" data-end=\"1762\"\u003e\n\u003cli data-section-id=\"ui2dup\" data-start=\"1546\" data-end=\"1609\"\u003e\n\u003cp data-start=\"1548\" data-end=\"1609\"\u003eProvides \u003cstrong data-start=\"1557\" data-end=\"1607\"\u003econtinuous clean power with zero transfer time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1263a14\" data-start=\"1610\" data-end=\"1671\"\u003e\n\u003cp data-start=\"1612\" data-end=\"1671\"\u003eProtects against voltage fluctuations, spikes and outages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1698l7d\" data-start=\"1672\" data-end=\"1762\"\u003e\n\u003cp data-start=\"1674\" data-end=\"1762\"\u003eEnsures stable operation for sensitive equipment \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1764\" data-end=\"1767\"\u003e\n\u003ch3 data-section-id=\"1xan3lp\" data-start=\"1769\" data-end=\"1803\"\u003eScalable and Flexible Design\u003c\/h3\u003e\n\u003cul data-start=\"1804\" data-end=\"2057\"\u003e\n\u003cli data-section-id=\"1levr6m\" data-start=\"1804\" data-end=\"1871\"\u003e\n\u003cp data-start=\"1806\" data-end=\"1871\"\u003e\u003cstrong data-start=\"1806\" data-end=\"1831\"\u003e10kVA \/ 10kW capacity\u003c\/strong\u003e for small to mid-sized critical loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"saak2s\" data-start=\"1872\" data-end=\"1907\"\u003e\n\u003cp data-start=\"1874\" data-end=\"1907\"\u003eRackmount or tower installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tpcso3\" data-start=\"1908\" data-end=\"1960\"\u003e\n\u003cp data-start=\"1910\" data-end=\"1960\"\u003eParallel capability for redundancy and expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wubilk\" data-start=\"1961\" data-end=\"2057\"\u003e\n\u003cp data-start=\"1963\" data-end=\"2057\"\u003eOptional maintenance bypass cabinet for safe servicing \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2059\" data-end=\"2062\"\u003e\n\u003ch3 data-section-id=\"1nnr3sy\" data-start=\"2064\" data-end=\"2099\"\u003eHigh Power Factor Performance\u003c\/h3\u003e\n\u003cul data-start=\"2100\" data-end=\"2268\"\u003e\n\u003cli data-section-id=\"jii7ok\" data-start=\"2100\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2102\" data-end=\"2156\"\u003e\u003cstrong data-start=\"2102\" data-end=\"2130\"\u003eUnity power factor (1.0)\u003c\/strong\u003e maximises usable output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"vxu5zc\" data-start=\"2157\" data-end=\"2268\"\u003e\n\u003cp data-start=\"2159\" data-end=\"2268\"\u003e\u003cstrong data-start=\"2159\" data-end=\"2186\"\u003e0.99 input power factor\u003c\/strong\u003e improves generator and grid compatibility \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2270\" data-end=\"2273\"\u003e\n\u003ch3 data-section-id=\"1xgahg2\" data-start=\"2275\" data-end=\"2317\"\u003eAdvanced Battery and Runtime Options\u003c\/h3\u003e\n\u003cul data-start=\"2318\" data-end=\"2543\"\u003e\n\u003cli data-section-id=\"jpnubk\" data-start=\"2318\" data-end=\"2353\"\u003e\n\u003cp data-start=\"2320\" data-end=\"2353\"\u003eScalable runtime configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uqdfpx\" data-start=\"2354\" data-end=\"2382\"\u003e\n\u003cp data-start=\"2356\" data-end=\"2382\"\u003eFast recharge capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nh8u54\" data-start=\"2383\" data-end=\"2443\"\u003e\n\u003cp data-start=\"2385\" data-end=\"2443\"\u003eCompatible with \u003cstrong data-start=\"2401\" data-end=\"2441\"\u003eVRLA and lithium-ion battery systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l8f71y\" data-start=\"2444\" data-end=\"2543\"\u003e\n\u003cp data-start=\"2446\" data-end=\"2543\"\u003eIntelligent battery monitoring for lifecycle optimisation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2545\" data-end=\"2548\"\u003e\n\u003ch3 data-section-id=\"1qv0uo3\" data-start=\"2550\" data-end=\"2595\"\u003eIntelligent Monitoring and Connectivity\u003c\/h3\u003e\n\u003cul data-start=\"2596\" data-end=\"2791\"\u003e\n\u003cli data-section-id=\"kk4cxy\" data-start=\"2596\" data-end=\"2652\"\u003e\n\u003cp data-start=\"2598\" data-end=\"2652\"\u003eIntegrated communication ports for remote monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18q00w9\" data-start=\"2653\" data-end=\"2700\"\u003e\n\u003cp data-start=\"2655\" data-end=\"2700\"\u003eSNMP, Modbus and network card compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"189wqo4\" data-start=\"2701\" data-end=\"2791\"\u003e\n\u003cp data-start=\"2703\" data-end=\"2791\"\u003eLCD interface for easy operation and diagnostics \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2793\" data-end=\"2796\"\u003e\n\u003ch2 data-section-id=\"156aygl\" data-start=\"2798\" data-end=\"2823\"\u003eTechnical Highlights\u003c\/h2\u003e\n\u003cp data-start=\"2825\" data-end=\"3380\"\u003eModel: \u003cstrong data-start=\"2832\" data-end=\"2875\"\u003eITA-10k00ALA102P00 \/ ITA-10k00AEA102P00\u003c\/strong\u003e\u003cbr data-start=\"2875\" data-end=\"2878\"\u003eCapacity: \u003cstrong data-start=\"2888\" data-end=\"2904\"\u003e10kVA \/ 10kW\u003c\/strong\u003e\u003cbr data-start=\"2904\" data-end=\"2907\"\u003eTopology: \u003cstrong data-start=\"2917\" data-end=\"2949\"\u003eOnline double conversion UPS\u003c\/strong\u003e\u003cbr data-start=\"2949\" data-end=\"2952\"\u003eInput Voltage: \u003cstrong data-start=\"2967\" data-end=\"2995\"\u003e380\/400\/415V three-phase\u003c\/strong\u003e\u003cbr data-start=\"2995\" data-end=\"2998\"\u003eOutput Voltage: \u003cstrong data-start=\"3014\" data-end=\"3078\"\u003e380\/400\/415V three-phase or configurable single-phase output\u003c\/strong\u003e\u003cbr data-start=\"3078\" data-end=\"3081\"\u003eEfficiency: \u003cstrong data-start=\"3093\" data-end=\"3133\"\u003eUp to 96.5% (online), 99% (ECO mode)\u003c\/strong\u003e\u003cbr data-start=\"3133\" data-end=\"3136\"\u003ePower Factor: \u003cstrong data-start=\"3150\" data-end=\"3176\"\u003e1.0 output, 0.99 input\u003c\/strong\u003e\u003cbr data-start=\"3176\" data-end=\"3179\"\u003eWaveform: \u003cstrong data-start=\"3189\" data-end=\"3207\"\u003ePure sine wave\u003c\/strong\u003e\u003cbr data-start=\"3207\" data-end=\"3210\"\u003eForm Factor: \u003cstrong data-start=\"3223\" data-end=\"3245\"\u003eRackmount or tower\u003c\/strong\u003e\u003cbr data-start=\"3245\" data-end=\"3248\"\u003eOperating Temperature: \u003cstrong data-start=\"3271\" data-end=\"3285\"\u003eUp to 50°C\u003c\/strong\u003e\u003cbr data-start=\"3285\" data-end=\"3288\"\u003eDesign: \u003cstrong data-start=\"3296\" data-end=\"3340\"\u003eDust-resistant, high ambient performance\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3382\" data-end=\"3385\"\u003e\n\u003ch2 data-section-id=\"izx4vd\" data-start=\"3387\" data-end=\"3410\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"3412\" data-end=\"3462\"\u003eThe Vertiv Liebert ITA2 10kVA UPS is designed for:\u003c\/p\u003e\n\u003cp data-start=\"3464\" data-end=\"3669\"\u003eData centres and server rooms\u003cbr data-start=\"3493\" data-end=\"3496\"\u003eNetwork closets and communications infrastructure\u003cbr data-start=\"3545\" data-end=\"3548\"\u003eIndustrial automation and control systems\u003cbr data-start=\"3589\" data-end=\"3592\"\u003eEdge computing environments\u003cbr data-start=\"3619\" data-end=\"3622\"\u003ePrecision instruments and small control rooms\u003c\/p\u003e\n\u003chr data-start=\"3671\" data-end=\"3674\"\u003e\n\u003ch2 data-section-id=\"1dz6auh\" data-start=\"3676\" data-end=\"3725\"\u003eWhy Choose the Vertiv Liebert ITA2 10kVA UPS\u003c\/h2\u003e\n\u003cp data-start=\"3727\" data-end=\"3922\"\u003eThe ITA2 10kVA delivers \u003cstrong data-start=\"3751\" data-end=\"3803\"\u003ecompact, efficient and reliable power protection\u003c\/strong\u003e, making it ideal for businesses operating in \u003cstrong data-start=\"3849\" data-end=\"3921\"\u003espace-constrained and mission-critical environments across Australia\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3924\" data-end=\"4074\"\u003eIts combination of \u003cstrong data-start=\"3943\" data-end=\"4007\"\u003ehigh efficiency, flexible deployment and advanced monitoring\u003c\/strong\u003e ensures long-term performance and reduced total cost of ownership.\u003c\/p\u003e\n\u003chr data-start=\"4076\" data-end=\"4079\"\u003e\n\u003ch2 data-section-id=\"1quhw3w\" data-start=\"4081\" data-end=\"4110\"\u003eCheck out our other services\u003c\/h2\u003e\n\u003cp data-start=\"4093\" data-end=\"4179\"\u003e👉 UPS Maintenance and Servicing\u003cbr data-start=\"4125\" data-end=\"4128\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/pages\/ups-maintenance\" title=\"UPS Maintenance\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/pages\/ups-maintenance\u003c\/a\u003e\u003ca data-start=\"4128\" data-end=\"4177\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.indigipc.com.au\/pages\/ups-maintenance\"\u003e\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-gmavja41.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"4181\" data-end=\"4283\"\u003e👉 UPS Installation and Commissioning\u003cbr data-start=\"4218\" data-end=\"4221\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/pages\/installation-commissioning\" title=\"UPS Install \u0026amp; Commission\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/pages\/installation-commissioning\u003c\/a\u003e\u003ca data-start=\"4221\" data-end=\"4281\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.indigipc.com.au\/pages\/installation-commissioning\"\u003e\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-gmavja41.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"4285\" data-end=\"4420\"\u003e👉 CRAC Cooling for Data Centres\u003cbr data-start=\"4317\" data-end=\"4320\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/crac-unit-cooling-brisbane-australia-precision-data-cooling\" title=\"CRAC Unit BLOG\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/blogs\/news\/crac-unit-cooling-brisbane-australia-precision-data-cooling\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-start=\"4441\" data-end=\"4444\"\u003e\n\u003ch2 data-section-id=\"13fxtuq\" data-start=\"4446\" data-end=\"4465\"\u003eFree Quote\u003c\/h2\u003e\n\u003cp data-start=\"4467\" data-end=\"4550\"\u003eLooking for a \u003cstrong data-start=\"4481\" data-end=\"4550\"\u003eVertiv Liebert ITA2 10kVA UPS supplier and installer in Australia\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4552\" data-end=\"4688\"\u003e👉 Contact Indigi Power and Cooling for expert advice, supply and installation across Brisbane, Sydney, Melbourne and Papua New Guinea\u003c\/p\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51644746268992,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/ita2-product-image-rack_f093aa7c-8ed1-47d9-8592-c10a99900957.webp?v=1774308277","url":"https:\/\/www.indigipc.com.au\/products\/vertiv-ita2-10kva-ups-australia","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}