{"product_id":"vertiv-ita2-30kva-ups-australia","title":"Vertiv™ Liebert® ITA2 | ITA-30kVA-3 PHASE | Indigi Power \u0026 Cooling","description":"\u003ch2 data-section-id=\"mm33w6\" data-start=\"155\" data-end=\"196\"\u003eVertiv Liebert ITA2 30kVA 3 Phase UPS | High Efficiency UPS for Data Centres and Critical Power in Australia\u003c\/h2\u003e\n\u003cp data-start=\"318\" data-end=\"481\"\u003eReliable 30kVA three-phase UPS system for data centres, industrial applications and critical infrastructure across Brisbane, Sydney, Melbourne and Papua New Guinea\u003c\/p\u003e\n\u003cp data-start=\"318\" data-end=\"481\"\u003e\u003cspan\u003eTo see more information regarding this  model checkout the \u003c\/span\u003e\u003ca href=\"https:\/\/www.vertiv.com\/493193\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/vertiv-liebert-ita2-5kva---40kva\/liebert-ita2-5-40kva-br-en-ap-1222.pdf\" title=\"ITA2 Brochure\" rel=\"noopener\" target=\"_blank\"\u003eBROCHURE, \u003c\/a\u003e\u003ca href=\"https:\/\/www.vertiv.com\/492e63\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/vertiv-liebert-ita2-5kva---40kva\/liebert-ita2-30kva--site-planning-datasheet.pdf\" target=\"_blank\" title=\"ITA2 Site Planning DOC\" rel=\"noopener\"\u003eSite Planning Documentation\u003c\/a\u003e\u003cspan\u003e \u0026amp; \u003c\/span\u003e\u003ca href=\"https:\/\/www.vertiv.com\/492e68\/globalassets\/products\/critical-power\/uninterruptible-power-supplies-ups\/vertiv-liebert-ita2-5kva---40kva\/liebert-ita2-30kva-ups---manual_v1.2.pdf\" target=\"_blank\" title=\"ITA2 30kVA Installation Manual\" rel=\"noopener\"\u003eInstallation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003chr data-start=\"483\" data-end=\"486\"\u003e\n\u003ch2 data-section-id=\"53drpp\" data-start=\"488\" data-end=\"509\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp data-start=\"511\" data-end=\"731\"\u003eThe \u003cstrong data-start=\"515\" data-end=\"569\"\u003eVertiv Liebert ITA2 30kVA UPS (ITA-30k00AL3302P00)\u003c\/strong\u003e is a high-performance \u003cstrong data-start=\"592\" data-end=\"631\"\u003eonline double conversion UPS system\u003c\/strong\u003e designed to deliver \u003cstrong data-start=\"652\" data-end=\"704\"\u003eclean, continuous and reliable three-phase power\u003c\/strong\u003e for critical environments.\u003c\/p\u003e\n\u003cp data-start=\"733\" data-end=\"985\"\u003eBuilt for flexibility and efficiency, this UPS supports \u003cstrong data-start=\"789\" data-end=\"827\"\u003erackmount and tower configurations\u003c\/strong\u003e, scalable battery runtimes and intelligent monitoring, making it ideal for \u003cstrong data-start=\"903\" data-end=\"984\"\u003edata centres, telecommunications, industrial automation and IT infrastructure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"987\" data-end=\"1150\"\u003eIts compact footprint and advanced design allow seamless integration into modern environments while reducing operating costs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1152\" data-end=\"1155\"\u003e\n\u003ch2 data-section-id=\"8k5xne\" data-start=\"1157\" data-end=\"1187\"\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1hf9xth\" data-start=\"1189\" data-end=\"1238\"\u003eHigh Efficiency and Reduced Operating Costs\u003c\/h3\u003e\n\u003cul data-start=\"1239\" data-end=\"1427\"\u003e\n\u003cli data-section-id=\"1r78qft\" data-start=\"1239\" data-end=\"1295\"\u003e\n\u003cp data-start=\"1241\" data-end=\"1295\"\u003eUp to \u003cstrong data-start=\"1247\" data-end=\"1293\"\u003e96.5% efficiency in double conversion mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"p1rksp\" data-start=\"1296\" data-end=\"1336\"\u003e\n\u003cp data-start=\"1298\" data-end=\"1336\"\u003eUp to \u003cstrong data-start=\"1304\" data-end=\"1334\"\u003e99% efficiency in ECO mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jq52g4\" data-start=\"1337\" data-end=\"1427\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1427\"\u003eLower power consumption and cooling requirements \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1429\" data-end=\"1432\"\u003e\n\u003ch3 data-section-id=\"1pcbtap\" data-start=\"1434\" data-end=\"1480\"\u003eTrue Online Double Conversion Protection\u003c\/h3\u003e\n\u003cul data-start=\"1481\" data-end=\"1705\"\u003e\n\u003cli data-section-id=\"ui2dup\" data-start=\"1481\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1483\" data-end=\"1544\"\u003eProvides \u003cstrong data-start=\"1492\" data-end=\"1542\"\u003econtinuous clean power with zero transfer time\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1263a14\" data-start=\"1545\" data-end=\"1606\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1606\"\u003eProtects against voltage fluctuations, spikes and outages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1b2ms6o\" data-start=\"1607\" data-end=\"1705\"\u003e\n\u003cp data-start=\"1609\" data-end=\"1705\"\u003eHandles multiple power disturbances for critical systems \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1707\" data-end=\"1710\"\u003e\n\u003ch3 data-section-id=\"1xan3lp\" data-start=\"1712\" data-end=\"1746\"\u003eScalable and Flexible Design\u003c\/h3\u003e\n\u003cul data-start=\"1747\" data-end=\"2014\"\u003e\n\u003cli data-section-id=\"9se0rx\" data-start=\"1747\" data-end=\"1811\"\u003e\n\u003cp data-start=\"1749\" data-end=\"1811\"\u003e\u003cstrong data-start=\"1749\" data-end=\"1774\"\u003e30kVA \/ 30kW capacity\u003c\/strong\u003e for medium to large critical loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1t435xw\" data-start=\"1812\" data-end=\"1855\"\u003e\n\u003cp data-start=\"1814\" data-end=\"1855\"\u003eRackmount or tower installation options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3v6tjr\" data-start=\"1856\" data-end=\"1917\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1917\"\u003eParallel capability for redundancy and capacity expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wubilk\" data-start=\"1918\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1920\" data-end=\"2014\"\u003eOptional maintenance bypass cabinet for safe servicing \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2016\" data-end=\"2019\"\u003e\n\u003ch3 data-section-id=\"1nnr3sy\" data-start=\"2021\" data-end=\"2056\"\u003eHigh Power Factor Performance\u003c\/h3\u003e\n\u003cul data-start=\"2057\" data-end=\"2244\"\u003e\n\u003cli data-section-id=\"50122j\" data-start=\"2057\" data-end=\"2119\"\u003e\n\u003cp data-start=\"2059\" data-end=\"2119\"\u003e\u003cstrong data-start=\"2059\" data-end=\"2087\"\u003eUnity power factor (1.0)\u003c\/strong\u003e maximises usable output power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"wq3x9m\" data-start=\"2120\" data-end=\"2244\"\u003e\n\u003cp data-start=\"2122\" data-end=\"2244\"\u003e\u003cstrong data-start=\"2122\" data-end=\"2149\"\u003e0.99 input power factor\u003c\/strong\u003e improves compatibility with generators and grid supply \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2246\" data-end=\"2249\"\u003e\n\u003ch3 data-section-id=\"1xgahg2\" data-start=\"2251\" data-end=\"2293\"\u003eAdvanced Battery and Runtime Options\u003c\/h3\u003e\n\u003cul data-start=\"2294\" data-end=\"2544\"\u003e\n\u003cli data-section-id=\"2dxakx\" data-start=\"2294\" data-end=\"2350\"\u003e\n\u003cp data-start=\"2296\" data-end=\"2350\"\u003eScalable battery configurations for extended runtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uqdfpx\" data-start=\"2351\" data-end=\"2379\"\u003e\n\u003cp data-start=\"2353\" data-end=\"2379\"\u003eFast recharge capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nh8u54\" data-start=\"2380\" data-end=\"2440\"\u003e\n\u003cp data-start=\"2382\" data-end=\"2440\"\u003eCompatible with \u003cstrong data-start=\"2398\" data-end=\"2438\"\u003eVRLA and lithium-ion battery systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14do0z8\" data-start=\"2441\" data-end=\"2544\"\u003e\n\u003cp data-start=\"2443\" data-end=\"2544\"\u003eIntelligent battery monitoring improves lifecycle performance \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2546\" data-end=\"2549\"\u003e\n\u003ch3 data-section-id=\"1qv0uo3\" data-start=\"2551\" data-end=\"2596\"\u003eIntelligent Monitoring and Connectivity\u003c\/h3\u003e\n\u003cul data-start=\"2597\" data-end=\"2800\"\u003e\n\u003cli data-section-id=\"1mzfhs\" data-start=\"2597\" data-end=\"2654\"\u003e\n\u003cp data-start=\"2599\" data-end=\"2654\"\u003eIntegrated communication ports and SNMP compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ob4b7z\" data-start=\"2655\" data-end=\"2703\"\u003e\n\u003cp data-start=\"2657\" data-end=\"2703\"\u003eRemote monitoring and diagnostics capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"16terzn\" data-start=\"2704\" data-end=\"2800\"\u003e\n\u003cp data-start=\"2706\" data-end=\"2800\"\u003eLCD interface for easy operation and system visibility \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2802\" data-end=\"2805\"\u003e\n\u003ch2 data-section-id=\"156aygl\" data-start=\"2807\" data-end=\"2832\"\u003eTechnical Highlights\u003c\/h2\u003e\n\u003cp data-start=\"2834\" data-end=\"3341\"\u003eModel: \u003cstrong data-start=\"2841\" data-end=\"2863\"\u003eITA-30k00AL3302P00\u003c\/strong\u003e\u003cbr data-start=\"2863\" data-end=\"2866\"\u003eCapacity: \u003cstrong data-start=\"2876\" data-end=\"2892\"\u003e30kVA \/ 30kW\u003c\/strong\u003e\u003cbr data-start=\"2892\" data-end=\"2895\"\u003eTopology: \u003cstrong data-start=\"2905\" data-end=\"2937\"\u003eOnline double conversion UPS\u003c\/strong\u003e\u003cbr data-start=\"2937\" data-end=\"2940\"\u003eInput Voltage: \u003cstrong data-start=\"2955\" data-end=\"2992\"\u003e380\/400\/415V three-phase (4 wire)\u003c\/strong\u003e\u003cbr data-start=\"2992\" data-end=\"2995\"\u003eOutput Voltage: \u003cstrong data-start=\"3011\" data-end=\"3039\"\u003e380\/400\/415V three-phase\u003c\/strong\u003e\u003cbr data-start=\"3039\" data-end=\"3042\"\u003eEfficiency: \u003cstrong data-start=\"3054\" data-end=\"3094\"\u003eUp to 96.5% (online), 99% (ECO mode)\u003c\/strong\u003e\u003cbr data-start=\"3094\" data-end=\"3097\"\u003ePower Factor: \u003cstrong data-start=\"3111\" data-end=\"3137\"\u003e1.0 output, 0.99 input\u003c\/strong\u003e\u003cbr data-start=\"3137\" data-end=\"3140\"\u003eWaveform: \u003cstrong data-start=\"3150\" data-end=\"3168\"\u003ePure sine wave\u003c\/strong\u003e\u003cbr data-start=\"3168\" data-end=\"3171\"\u003eForm Factor: \u003cstrong data-start=\"3184\" data-end=\"3206\"\u003eRackmount or tower\u003c\/strong\u003e\u003cbr data-start=\"3206\" data-end=\"3209\"\u003eOperating Temperature: \u003cstrong data-start=\"3232\" data-end=\"3246\"\u003eUp to 50°C\u003c\/strong\u003e\u003cbr data-start=\"3246\" data-end=\"3249\"\u003eDesign: \u003cstrong data-start=\"3257\" data-end=\"3301\"\u003eDust-resistant, high ambient performance\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3343\" data-end=\"3346\"\u003e\n\u003ch2 data-section-id=\"izx4vd\" data-start=\"3348\" data-end=\"3371\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"3373\" data-end=\"3423\"\u003eThe Vertiv Liebert ITA2 30kVA UPS is designed for:\u003c\/p\u003e\n\u003cp data-start=\"3425\" data-end=\"3679\"\u003eData centres and server rooms\u003cbr data-start=\"3454\" data-end=\"3457\"\u003eTelecommunications and network infrastructure\u003cbr data-start=\"3502\" data-end=\"3505\"\u003eIndustrial automation and control systems\u003cbr data-start=\"3546\" data-end=\"3549\"\u003eHealthcare and critical infrastructure\u003cbr data-start=\"3587\" data-end=\"3590\"\u003eCommercial and enterprise IT environments\u003cbr data-start=\"3631\" data-end=\"3634\"\u003eEdge and distributed computing environments\u003c\/p\u003e\n\u003chr data-start=\"3681\" data-end=\"3684\"\u003e\n\u003ch2 data-section-id=\"1t6w1nv\" data-start=\"3686\" data-end=\"3735\"\u003eWhy Choose the Vertiv Liebert ITA2 30kVA UPS\u003c\/h2\u003e\n\u003cp data-start=\"3737\" data-end=\"3917\"\u003eThe ITA2 30kVA delivers \u003cstrong data-start=\"3761\" data-end=\"3820\"\u003escalable, high-efficiency and reliable power protection\u003c\/strong\u003e, making it ideal for businesses operating in \u003cstrong data-start=\"3866\" data-end=\"3916\"\u003emission-critical environments across Australia\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3919\" data-end=\"4064\"\u003eIts combination of \u003cstrong data-start=\"3938\" data-end=\"3997\"\u003ecompact design, high efficiency and advanced monitoring\u003c\/strong\u003e ensures long-term performance and reduced total cost of ownership.\u003c\/p\u003e\n\u003chr data-start=\"4066\" data-end=\"4069\"\u003e\n\u003cp data-start=\"4102\" data-end=\"4188\"\u003e👉 UPS Maintenance and Servicing\u003cbr data-start=\"4134\" data-end=\"4137\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/pages\/ups-maintenance\" title=\"UPS Maintenance\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/pages\/ups-maintenance\u003c\/a\u003e\u003ca data-start=\"4137\" data-end=\"4186\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.indigipc.com.au\/pages\/ups-maintenance\"\u003e\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-gmavja41.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"4190\" data-end=\"4292\"\u003e👉 UPS Installation and Commissioning\u003cbr data-start=\"4227\" data-end=\"4230\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/pages\/installation-commissioning\" title=\"UPS Install \u0026amp; Commission\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/pages\/installation-commissioning\u003c\/a\u003e\u003ca data-start=\"4230\" data-end=\"4290\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.indigipc.com.au\/pages\/installation-commissioning\"\u003e\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-gmavja41.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"4294\" data-end=\"4429\"\u003e👉 CRAC Cooling for Data Centres\u003cbr data-start=\"4326\" data-end=\"4329\"\u003e\u003ca href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/crac-unit-cooling-brisbane-australia-precision-data-cooling\" title=\"CRAC Unit BLOG\" rel=\"noopener\" target=\"_blank\"\u003ehttps:\/\/www.indigipc.com.au\/blogs\/news\/crac-unit-cooling-brisbane-australia-precision-data-cooling\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"4294\" data-end=\"4429\"\u003e \u003c\/p\u003e\n\u003ch3 data-start=\"4294\" data-end=\"4429\"\u003eLooking for a \u003cstrong data-start=\"4471\" data-end=\"4540\"\u003eVertiv Liebert ITA2 30kVA UPS supplier and installer in Australia\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"4294\" data-end=\"4429\"\u003e👉 Contact Indigi Power and Cooling for expert advice, supply and installation across Brisbane, Sydney, Melbourne and Papua New Guinea\u003c\/p\u003e\n\u003cp data-start=\"4294\" data-end=\"4429\"\u003e\u003ca data-start=\"4329\" data-end=\"4427\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.indigipc.com.au\/blogs\/news\/crac-unit-cooling-brisbane-australia-precision-data-cooling\"\u003e\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse href=\"\/cdn\/assets\/sprites-core-gmavja41.svg#304883\" fill=\"currentColor\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Indigi Power \u0026 Cooling","offers":[{"title":"Default Title","offer_id":51642254393664,"sku":null,"price":0.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/8375\/5840\/files\/ita2-product-image-rack_1.webp?v=1774232653","url":"https:\/\/www.indigipc.com.au\/products\/vertiv-ita2-30kva-ups-australia","provider":"Indigi  Power \u0026 Cooling","version":"1.0","type":"link"}