Evikon E2673 Off-Gassing Detector
Hydrogen and VOC Detection for Battery Rooms, BESS, Data Centres and EV Charging Stations
The Evikon E2673 is a fixed gas detector purpose-built for battery-based applications. It simultaneously monitors for hydrogen (H2) and volatile organic compounds (VOCs) on a single unit, with integrated relative humidity and temperature measurement. Designed around maintenance-free long-life sensing technologies, the E2673 provides continuous early warning of battery off-gassing events in environments where delayed detection can result in fire, explosion, or toxic gas exposure.
Supplied by Indigi Power & Cooling across Australia.
Applications
-
Battery Energy Storage Systems (BESS)
-
Data centres and UPS battery rooms
-
EV charging stations
-
Battery manufacturing facilities
-
Critical infrastructure with lead-acid or lithium-ion battery banks
Why the E2673 for Battery Environments
Battery off-gassing is the primary hazard in BESS, UPS rooms, and data centre battery installations. Hydrogen is produced during the charging of lead-acid batteries and released during lithium-ion thermal runaway events. VOCs, including electrolyte vapours such as DEC and DEMC, are early markers of lithium-ion cell degradation and off-gassing, often present well before any visible smoke or heat alarm triggers.
The E2673 detects both gases simultaneously on one unit. There is no need for separate hydrogen and VOC detectors in the same zone, reducing installation cost and simplifying integration. With a sensor lifetime of approximately 15 years and no scheduled sensor replacement required, the E2673 delivers a low total cost of ownership for long-term facility monitoring.
Three SPST relays (NC logic) allow direct hardwired connection to fire safety panels, ventilation fans, and audible or visual alarm devices, providing immediate automated response when alarm thresholds are reached. RS485 Modbus RTU enables integration with BMS, SCADA, and fire safety systems.
Technical Specifications
| Parameter | Detail |
|---|---|
| Model | E2673 |
| Manufacturer | Evikon MCI |
| Gases Detected | Hydrogen (H2), VOCs (electrolyte vapours including DEC and DEMC) |
| Also Measures | Relative Humidity (RH), Ambient Temperature |
| H2 Sensor Technology | Thermal conductivity |
| VOC Sensor Technology | MOS (Metal Oxide Semiconductor) |
| Sampling Method | Diffusion / convection |
| H2 Detection Range | 0 to 100 %LEL H2 |
| VOC Detection Range | 0 to 500 VOC index |
| RH + Temperature Range | 0 to 100 %RH, -40 to +75 degrees C |
| H2 Resolution | 0.02 %LEL |
| Sensor Lifetime | Approximately 15 years (maintenance-free) |
| Power Supply | 10 to 36 VDC |
| Digital Interface | RS485 Modbus RTU |
| Alarm / Fault Outputs | 3 x SPST relays (NC logic), rated 300 mA, 30 VDC |
| Enclosure Material | Silver anodised aluminium alloy |
| Mounting | DIN-rail with wall mount option |
| IP Rating | IP40 |
| Dimensions | H94 x W56 x D32 mm |
| Operating Temperature | -40 to +75 degrees C |
| Operating Humidity | 0 to 100 %RH |
| Certifications | CE |
Key Features
-
Simultaneous hydrogen and VOC detection on a single unit
-
Maintenance-free sensors with approximately 15-year service life
-
Three SPST relays for direct connection to fire panels, ventilation, and alarms
-
RS485 Modbus RTU for BMS, SCADA, and fire safety system integration
-
Compact DIN-rail mount with wall mount option for flexible installation
-
Covers the full hydrogen LEL range (0 to 100 %LEL) and VOC index (0 to 500)
-
Integrated humidity and temperature measurement
-
Suitable for operating temperatures from -40 to +75 degrees C
-
Silver anodised aluminium alloy enclosure, robust for industrial environments
Documents
Supply and Installation by Indigi Power & Cooling
Indigi Power & Cooling supplies Evikon MCI gas detection systems and provides installation, commissioning, and integration services across Queensland, New South Wales, Victoria, and Papua New Guinea. The E2673 is installed as part of a complete gas detection solution for battery rooms, BESS containers, and data centre UPS rooms, including sensor placement design based on gas density behaviour, relay wiring to fire panels or ventilation systems, and RS485 integration to your BMS or SCADA platform.
Related Products and Services

Partner with Us
Reliable Power & Cooling Solutions from Indigi Power & Cooling Expert supply, installation, and contracting services for critical infrastructure across Australia.