UPS power and CRAC cooling specialist

Uninterruptible Power Supply (UPS) & Data Centre Cooling SpecialistsAustralia-Wide

RegisteredSupply Nation
RegisteredICN Gateway
Emergency response24 / 7
Call1800 046 344
Vertiv CRV in-row CRAC units and 100kVA Vertiv APM UPS systems in an Australian data centre aisle, inspected by Indigi Power and Cooling

UPS systems / CRAC cooling / Batteries

Indigi Power and Cooling protects Australia's critical infrastructure with UPS systems, batteries, CRAC cooling, installation, maintenance and 24/7 emergency response. Indigenous and Veteran-owned.

Request a quote →

Our services

UPS and precision coolingBrisbane and Australia-wide

View all services →

Shop the range

Uninterruptible powerSupplied, installed, maintained

View all UPS systems →
Eaton 9SX 15kVA and 20kVA online double-conversion UPS Online double-conversion

Online double-conversion

Eaton 9SX 15kVA and 20kVA

Online double-conversion protection for server rooms and critical plant, with Australian-pattern outlets.

Capacity
15 and 20 kVA
Topology
Double-conversion
Format
Tower
View product →
Vertiv Liebert GXT5 6000VA rack and tower online UPS Rack and tower

Rack and tower

Vertiv Liebert GXT5 6000VA

Single-phase online UPS that mounts in a rack or stands as a tower, with extended runtime options.

Capacity
6000 VA / 6000 W
Format
Rack / tower 5U
Topology
Double-conversion
View product →
Socomec ITYS E compact tower UPS Tower online UPS

Tower online UPS

Socomec ITYS E

Compact tower UPS from 1 to 10 kVA with wide battery configurability for comms and server rooms.

Capacity
1 to 10 kVA
Format
Compact tower
Batteries
Configurable
View product →
APC Smart-UPS On-Line 2200VA 2U rackmount UPS Rack-mount 2U

Rack-mount 2U

APC Smart-UPS On-Line 2200VA

SRT2200RMXLI-NC with network management card and extended runtime, supplied with the rail kit.

Capacity
2200 VA / 1980 W
Format
2U rackmount
Outlets
8x C13, 2x C19
View product →
Vertiv Liebert GXE 6 to 10kVA online double-conversion UPS Online double-conversion

Online double-conversion

Vertiv Liebert GXE 6 to 10kVA

Vertiv's essential online double-conversion tower UPS for server rooms that need protection without complexity.

Capacity
6 to 10 kVA
Format
Tower
Topology
Double-conversion
View product →
PowerShield Centurion RT 10kVA long run rackmount UPS Rack-mount long run

Rack-mount long run

PowerShield Centurion RT 10kVA

Highest single-phase power density in the PowerShield range, configured for external battery banks.

Capacity
10 kVA
Format
Rack / tower
Runtime
Long run
View product →
PowerShield Centurion Pro 40kVA three-phase UPS cabinet Three-phase

Three-phase

Centurion Pro 40kVA three-phase

Three-phase in, three-phase out, configured long run without internal batteries for external cabinets.

Capacity
40 kVA / 40 kW
Configuration
Three-phase 3-3
Runtime
Long run
View product →
Vision 6FM120S-X 12V 120Ah VRLA UPS replacement battery Replacement battery

Replacement battery

Vision 6FM120S-X 12V 120Ah

FM series VRLA replacement battery for UPS, telecom and electrical utility applications.

Voltage
12 V
Capacity
120 Ah, 20 HR
Chemistry
Sealed lead-acid
View product →

Precision cooling

CRAC and data centreCooling, serviced nationally

View all CRAC cooling →
Vertiv Liebert PEX4 CRAC unit open during maintenance CRAC maintenance

CRAC maintenance

CRAC Unit Maintenance

Scheduled precision cooling servicing across every topology, to AS/NZS 3666 and ASHRAE TC 9.9.

Setpoint
18 to 27 C
Standard
ASHRAE TC 9.9
Coverage
Australia-wide
View service →
Vertiv Liebert PDX direct expansion CRAC unit Direct expansion

Direct expansion

DX CRAC Servicing

Self-contained refrigeration circuits and the outdoor condenser, where most DX capacity quietly disappears.

Capacity
5 to 100+ kW
Rejection
Air-cooled
Circuit
Self-contained
View service →
Vertiv Liebert PCW chilled water CRAC and CRAH unit Chilled water and CRAH

Chilled water and CRAH

CHW CRAC and CRAH

Coils fed from central chiller plant, with no compressor in the unit. The efficient option at scale.

Heat source
Chilled water
Compressor
None
Best for
High density
View service →
Vertiv Liebert water-cooled CRAC unit Condenser water

Condenser water

CDW CRAC Servicing

Water-cooled condensers rejecting to a cooling tower, plus the loop, valves and water treatment behind them.

Rejection
Cooling tower
Loop
Condenser water
Scale
Mid to large
View service →
STULZ CyberAir 3PRO DX precision air conditioning unit for Australian data centre cooling STULZ CRAC unit

STULZ CRAC unit

STULZ CyberAir 3PRO DX

Direct expansion CRAC from 20 to 150 kW in six sizes, with downflow, upflow and raised-floor air conduction. Every size fits through a standard doorway.

Capacity
20 to 150 kW
EER
Up to 5.6
Free cooling
Direct or indirect
View product →
Vertiv Liebert PEX4 precision cooling unit with inverter compressor and EC fans Vertiv Liebert unit

Vertiv Liebert unit

Vertiv Liebert PEX4

Inverter compressor, EC fans and microchannel coils in a compact footprint. Part-load COP above 5.5 and 50 per cent less refrigerant than tube and fin.

Compressor
Inverter BPM
Part-load COP
Over 5.5
Refrigerant
R410A
View product →
Vertiv Liebert MC condenser with EC fans Genuine parts

Genuine parts

Liebert CRAC Spare Parts

Genuine Emerson and Vertiv components, from EC fans and filters to controllers and expansion valves.

Brands
Emerson, Vertiv
Stock
Critical spares
Supply
Australia-wide
View service →
Clients

Trusted By Clients Throughout Australia and the Pacific

Defence, government, healthcare, industry and telecommunications operators across Australia and the Pacific Islands rely on Indigi Power and Cooling to keep their UPS and precision cooling systems running.

Visy logo
Daltron logo
Royal Australian Navy logo
QBuild, Queensland Government Department of Public Works logo
NSW Government logo
Ela Group of Companies logo
Queensland Government logo
Meddent, Brian Bell Group logo
IVF Australia logo
R and A Marine Services logo

Supply Nation and ICN Gateway registered. Indigenous and Veteran owned.

Questions

UPS and coolingquestions answered

The questions Australian facilities teams actually search for, with real figures rather than "contact us for pricing". Every price is ex GST, metro, and is the same number we would quote you on the phone.

How much does UPS maintenance cost in Australia?From $720

A one-off UPS service is $720 ex GST per unit in metro Brisbane, Sydney and Melbourne, and includes battery impedance testing, a thermographic scan of terminations under load, transfer testing, firmware checks and a written report with measured values.

A standard annual maintenance plan is $1,940 ex GST per year, covering scheduled visits, operational testing, calibration, priority fault response and an annual compliance report. Critical care plans with 24/7 response to an agreed SLA are quoted after consultation.

Multi-unit sites and multi-site fleets are quoted individually, with the per-unit rate falling as unit count rises. Regional and remote sites attract a mobilisation charge, which is why we combine nearby sites into one visit wherever possible. Full detail on UPS maintenance plans.

How much does server room cooling cost to install?$8k to $60k+

For a designed and commissioned room in Australia, budget roughly $8,000 to $15,000 for a small comms room on a single split or wall-mounted precision unit, $25,000 to $45,000 for a mid-size server room with redundancy, and $45,000 to $60,000 and above for a larger room or a data hall with multiple units and containment.

The variables that move that number most are redundancy (N or N+1), whether the condenser can be sited near the room or needs a long pipe run and crane access, and whether the electrical supply can carry the new load without a switchboard upgrade. The unit itself is rarely the expensive part.

The cheapest possible mistake is sizing on nameplate ratings instead of measured load, which routinely produces double the cooling a room needs and a unit that short cycles because of it. See server room cooling.

How much does UPS battery replacement cost?On assessment

Battery replacement is quoted on assessment rather than from a list, because the number is driven by four things: the chemistry (VRLA, AGM or lithium-ion), how many blocks are in the string, whether the cabinet or rack can be reused, and whether the old batteries need collection and recycling.

What we will not do is quote a replacement without testing first. Impedance testing tells you whether the whole string genuinely needs replacing or whether a small number of failing blocks are dragging the string down, and those are very different invoices. On a fleet, testing usually pays for itself by identifying which units can safely wait another year.

For a working estimate before you call, use the battery replacement cost calculator. See also battery maintenance and replacement.

How much does a CRAC unit cost?Installed cost is the number

The unit itself is rarely the number that decides the project. Precision cooling units sold in Australia range from a few thousand dollars for a small wall-mounted or rack-mounted unit through to the high tens of thousands for a large floor-standing CRAC with redundancy, and quoting a single figure for "a CRAC unit" is close to meaningless without the capacity and the configuration.

The installed cost is the useful number, and for a designed and commissioned room that runs roughly $8,000 to $15,000 for a small comms room, $25,000 to $45,000 mid-size, and $45,000 to $60,000 and above for a data hall. Condenser siting, pipe runs, crane access and whether the switchboard can carry the load routinely cost more than the unit.

Send us the room size, the IT load in kW and a photo of the space and we will quote the installed number rather than the sticker price. See CRAC installation.

How often should a UPS be serviced?Annually, minimum

At least once a year for single-phase systems, and twice a year for three-phase or mission-critical installations. That is the manufacturer minimum and the interval most warranties are written against.

A professional service covers battery impedance testing, thermographic imaging of connections, transfer and bypass testing, firmware checks, fan and capacitor condition, and cleaning. Between visits, monthly visual checks of alarms, ventilation and ambient temperature are worth doing in house.

Sites in healthcare, data centres, defence, banking and mining are usually on a more frequent schedule under their own compliance framework rather than the manufacturer's. See UPS maintenance.

How often should a CRAC unit be serviced?Quarterly

Quarterly professional servicing for anything supporting critical infrastructure, with monthly or bi-monthly in-house checks on filters, condensate pumps and alarms. The annual visit adds electrical inspection with a thermographic scan, full coil cleaning inside and out, compressor performance testing and a complete diagnostic review.

Queensland, Northern Territory and northern Western Australian sites should complete the annual comprehensive service before October, so the condenser is clean going into summer rather than being cleaned in response to a high pressure trip. Coastal and dusty industrial sites need the condenser washed more often than annually.

Refrigerant work must be carried out under ARCtick licence. See CRAC maintenance.

What is a CRAC unit?Precision cooling

A CRAC unit, or computer room air conditioner, is a precision cooling system designed for data centres, server rooms and telecommunications facilities. Unlike comfort air conditioning built for people, a CRAC unit runs continuously, handles concentrated heat loads, and holds strict temperature and humidity tolerances.

It keeps IT equipment inside the ASHRAE recommended envelope of 18 to 27 degrees Celsius at the rack inlet, holds relative humidity in a controlled band to prevent both static discharge and condensation, is engineered for a high sensible heat ratio because electronics produce dry heat rather than moisture, and continuously filters dust out of the air.

Configurations are downflow, which discharges cold air into a raised floor plenum, and upflow, which discharges upward into the room for spaces without a raised floor.

What is the difference between a CRAC unit and a CRAH unit?Refrigerant vs water

A CRAC unit contains its own refrigerant circuit and compressor, and rejects heat through an outdoor condenser. It is self contained: no chiller, no central plant, and one unit failing does not take the room with it.

A CRAH unit, computer room air handler, has no compressor. It passes room air over a chilled water coil fed from a central chiller plant. It is more efficient at scale and quieter in the room, but plant failure affects every unit at once and it brings water treatment obligations with it.

They look nearly identical from the front, which is why the distinction is missed so often. The quickest test is whether there is refrigerant pipework to an outdoor condenser or chilled water pipework to a plant room. We service both, plus condenser water units. See DX servicing and CHW and CRAH maintenance.

What is the life expectancy of a CRAC unit?15 to 20 years

Around 15 to 20 years with proper maintenance, and considerably less without it. Units on coastal sites corrode faster because salt attacks fins, fasteners and casing, and fin erosion permanently reduces heat transfer area in a way cleaning cannot recover.

The decision to repair or replace usually turns on the refrigerant rather than the mechanics. Australia is progressively reducing the volume of hydrofluorocarbon refrigerant that can be imported, so an older unit running a high global warming potential blend, with a slow leak and an ageing compressor, eventually reaches a point where recharging it is no longer cheap.

We record refrigerant type and charge at every visit and flag which units would be expensive to recharge, so the replacement decision lands in a budget cycle rather than during a failure.

What temperature should a server room be?18 to 27 degrees C

The ASHRAE recommended envelope is 18 to 27 degrees Celsius measured at the rack inlet, not at the wall thermostat and not at the return air grille. Where you measure changes the answer, and rack inlet is the only reading that reflects what the equipment actually experiences.

Running colder than this does not make equipment safer, it just costs more to run. The more useful measurement is the spread from the top of the rack face to the bottom. A wide spread is an airflow and containment problem, and adding cooling capacity will not fix it, it will simply cost money for nothing.

Relative humidity matters as well. Too dry risks static discharge, too wet risks condensation and corrosion.

What happens if a server room gets too hot?Minutes, not hours

Faster than most people expect. A room full of IT equipment with the cooling stopped can climb past safe operating temperature within minutes, because there is nowhere for concentrated heat to go. Servers begin thermal throttling first, then shut down to protect themselves, and equipment that runs hot repeatedly without ever tripping still has its service life shortened.

The slower damage is the expensive one. Sustained warm running degrades UPS batteries badly, and a room running five degrees warm will take years off a battery string. That cost arrives disguised as an early battery replacement rather than as a cooling fault, so the two are rarely connected.

Excess heat in a battery room is also a fire risk, which is why temperature alarming that reaches someone who still works there matters more than the alarm existing at all.

How often should UPS batteries be replaced?Every 3 to 5 years

Typically 3 to 5 years for VRLA batteries and longer for lithium-ion, against a UPS unit life of 8 to 12 years. Batteries are almost always the first thing to need replacing.

Temperature is the dominant factor, well ahead of cycle count for most Australian sites. Every sustained increase above the rated ambient shortens life measurably, which is the practical reason UPS and cooling should be specified together rather than as separate trades.

Impedance testing at each service catches a failing string years before it fails under load, which matters because a UPS with a degraded battery gives no warning until the day it is needed. Estimate a replacement with the battery replacement cost calculator.

Do you need a UPS in Australia, or is a generator enough?Both, different jobs

They solve different problems and neither substitutes for the other. A UPS transfers to battery in milliseconds, so connected equipment never sees the interruption. A generator takes seconds to start and come up to load, by which time unprotected servers have already dropped.

The UPS covers the gap. Runtime is deliberately short, often 5 to 15 minutes, which is enough to ride out a brief outage or to hold the load until a generator picks it up. A UPS also corrects brownouts, surges and voltage variation that a generator does nothing about.

On sites without a generator, the UPS runtime needs to cover a controlled shutdown instead. That is a sizing decision, not a product decision. Start with the UPS runtime and battery calculator.

Who is legally allowed to work on a UPS or CRAC unit in Australia?Licensed and ARCtick

Electrical work on a UPS is licensed electrical work and must be carried out by a licensed electrician. Handling refrigerant in a CRAC unit requires an ARCtick licence issued under the Ozone Protection and Synthetic Greenhouse Gas Management Regulations, and it is an offence to work on a refrigerant circuit without one.

Installations should be completed to Australian Standards including AS/NZS 3000 for electrical installations and AS IEC 62040 for uninterruptible power systems.

A contractor should be able to produce both licences plus the refrigerant charge record for your system. Ask for them before the first visit rather than after. Indigi holds both, and is an Indigenous and Veteran-owned business registered with Supply Nation and listed on ICN Gateway.

If your question is not here, call 1800 046 344 or email sales@indigipc.com.au. Tell us the site, the load and what is on it, and we will size, supply, install and maintain the power and the cooling as one package.

  • Quality and Safety

    We operate with full compliance and certifications, delivering durable, high- performance solutions.

  • Nationwide Support

    Our agile teams and logistics network keep operations running—no matter how remote.

  • Indigenous & Veteran-Owned

    We’re committed to creating opportunities for First Nations and Veteran communities through skilled trades, procurement, and project delivery.Partnering with us helps you meet Indigenous procurement targets in a genuine and impactful way.

  •  Proven Capability

    With extensive experience across industrial, commercial, and government sectors, we ensure every installation meets the highest safety and performance standards.

Partners
Contact form

Partner with Us

Reliable Power & Cooling Solutions from Indigi Power & Cooling
Expert supply, installation, and contracting services for critical infrastructure across Australia.

Request a Quote