EPDM Coolant Hose for Data Centre Liquid Cooling, 959 Autolock Evolution
EPDM Coolant Hose for Data Centre Liquid Cooling, 959 Autolock Evolution
This is a flexible EPDM hose made specifically for data centre water cooling, with a peroxide-cured tube that is free of calcium and zinc and a UL 94 V0 flame rated cover. Those two properties are the whole reason it exists as a separate product from general purpose rubber hose. Manufactured by Alfagomma as the 959 Autolock Evolution range and supplied by Indigi Power and Cooling, who buy direct. Available with a blue cover (959AE) or red cover (959AH) so supply and return are unambiguous at the rack.
Dimensions and ratings
| Internal diameter | ID (in) | Outside diameter | Working pressure | Burst pressure | Min. bend radius | Weight |
|---|---|---|---|---|---|---|
| 6.0 mm | 1/4 inch | 15.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 36 mm | 0.190 kg/m |
| 10.0 mm | 3/8 inch | 19.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 60 mm | 0.270 kg/m |
| 13.0 mm | 1/2 inch | 22.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 78 mm | 0.330 kg/m |
Construction
Tube: black peroxide-cured EPDM, calcium and zinc free. Reinforcement: high tensile textile braids. Cover: EPDM, abrasion, ozone and fire resistant, blue (959AE) or red (959AH). Operating range minus 40 to plus 120 degrees Celsius. Compatible with push-on fittings, so an assembly can be made up without crimping equipment during an incident.
Why the chemistry matters
A general purpose rubber compound leaches calcium and zinc ions into the coolant. Those ions precipitate inside cold plate microchannels, which are measured in fractions of a millimetre. The first symptom is not a leak: it is reduced flow through one cold plate, presenting as thermal throttling on a single node, months after installation. By then almost nobody connects it back to the hose. A peroxide-cured, calcium and zinc free compound removes the mechanism entirely.
The UL 94 V0 cover rating is the class required for a flexible plastic assembly inside an occupied data hall, and it is the specification your fire engineer will ask about by name.
Frequently asked questions
Which size do I need?
Size the coupling to the flow the rack actually needs first, then match the hose to the coupling. As a guide, 6 mm ID pairs with UQD02, 10 mm with UQD04 and 13 mm with UQD06. Then check the published minimum bend radius against the real cable route in the rack rather than against the drawing.
What is the difference between 959AE and 959AH?
Cover colour only. 959AE is blue and 959AH is red. Both share the same black peroxide-cured EPDM tube, textile braid reinforcement, UL 94 V0 cover, 20 bar working pressure and temperature range. The colour exists so supply and return are unambiguous at the rack, which is the control that prevents a reversed connection.
Can I use ordinary hydraulic or industrial hose instead?
No, and it is the most expensive shortcut available on a liquid cooling project. General purpose hose is not calcium and zinc free, usually carries no flame rating, and its seal material may not suit your coolant. The resulting failure is slow, presents as thermal throttling months later, and is very hard to trace back.
Do you supply it cut to length with fittings?
Yes. We quote assemblies against your rack elevation with the specified end fittings and cover colour, tagged at both ends, and we check the lengths against the actual cable route. Bulk hose by the metre can also be quoted.
Why is there no price shown?
Length, end fittings, cover colour and quantity all change the number, so these are quoted rather than listed. Send a rack elevation or a cut list and we will come back with a price.
Related
- All liquid cooling hose and fittings: the full connection layer
- Liquid cooling solutions: CDUs, rear door and immersion equipment
- Installation and maintenance: pipework, flush, fill and commissioning
- DCIM and monitoring: where leak and flow alarms should land
|
Quoted against your rack elevation Send the rack layout, the cold plate port types and the flow per node and we will come back with sizes, assembly lengths, part numbers and an installed price. Indigi Power and Cooling buys these components direct, and is Indigenous and Veteran owned, Supply Nation and ICN Gateway registered. Request a quote |