Collection: Data Centre Liquid Cooling Hose, Fittings and Quick Disconnect Couplings
Data centre liquid cooling hose is a flame-rated, chemically clean flexible hose built specifically for the technology cooling loop, and it connects to cold plates through flat-face quick disconnect couplings sized to the Open Compute Project UQD specification in UQD02, UQD04 and UQD06.
These are the parts that sit between a coolant distribution unit and the rack. Indigi Power and Cooling supplies them, buying direct from the manufacturer, and installs and commissions the loop they go into. As an Indigenous and Veteran owned specialist we are Supply Nation and ICN Gateway registered.
Which collection
This one is the connection layer. If you are still choosing between rear door, direct-to-chip and immersion at the equipment level, start with data centre liquid cooling solutions instead.
That collection covers coolant distribution units, rear door heat exchangers and immersion systems. This one covers what connects that equipment to your servers: hose, couplings, manifolds and the stainless pipework between them.
It is the layer most projects forget to budget for. The CDU and the servers usually come from one vendor and arrive with a specification, and then somebody has to actually join them together, to a chemistry and fire standard that will survive years in an occupied hall.
20 bar
Working pressure across all three hose sizes, against a 60 bar burst pressure
UL 94 V0
Flame rating on the hose cover, the class required for an occupied data hall
-40 to 120C
Hose operating range, far wider than any technology cooling loop needs
100%
Share of UQD couplings helium leak tested, not batch sampled
The difference
Why this is not ordinary industrial hose
The single most expensive shortcut on a liquid cooling project is using general purpose rubber hose because it fits and holds pressure. It will do both, and it will still cost you the loop.
A general purpose rubber compound leaches calcium and zinc ions into the coolant. Those ions precipitate inside cold plate microchannels, which are measured in fractions of a millimetre.
The first symptom is not a leak. It is reduced flow through one cold plate, presenting as thermal throttling on a single node, months after installation. By then almost nobody connects it back to the hose.
Peroxide cured, calcium and zinc free
No ions to leach, so nothing plates out inside the microchannels. This is the whole reason a separate data centre hose range exists.
UL 94 V0 rated cover
The class required for a flexible plastic assembly in an occupied data hall. It is the specification your fire engineer will ask about by name.
High tensile textile braid
Kink resistance and a tight bend radius, so the assembly routes behind existing cable management rather than in front of it.
Blue and red cover
Supply and return identified by colour at the coupling. At 3am with a torch, this is the control that stops a reversed connection.
Flat face couplings
Minimal spill on disconnect and, more importantly, no air ingestion on reconnection. Air in a technology cooling loop causes cavitation and corrosion.
Helium leak tested, every unit
Helium finds leak paths that a water pressure decay test will not. Across hundreds of connection points at 20 bar, that difference matters.
Hose
EPDM coolant hose
The reference product in this class is the Alfagomma 959 Autolock Evolution range, supplied with a blue cover as 959AE and a red cover as 959AH. Construction is a black peroxide-cured EPDM tube, high tensile textile braids, and an abrasion, ozone and fire resistant EPDM cover. Compatible with push-on fittings, so an assembly can be made up without crimping equipment during an incident.
| Internal diameter | ID (in) | Outside diameter | Working pressure | Burst pressure | Min. bend radius | Weight |
|---|---|---|---|---|---|---|
| 6.0 mm | 1/4 inch | 15.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 36 mm | 0.190 kg/m |
| 10.0 mm | 3/8 inch | 19.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 60 mm | 0.270 kg/m |
| 13.0 mm | 1/2 inch | 22.0 mm | 20 bar (300 psi) | 60 bar (900 psi) | 78 mm | 0.330 kg/m |
Couplings
UQD quick disconnect couplings
Flat-face, push-to-connect stainless steel couplings built for liquid cooling loops. EPDM seals to match the hose chemistry, colour coding available, sizes 1/4 inch to 5/8 inch. UQD sizing comes from the Open Compute Project specification, which is why several manufacturers all offer UQD02, UQD04 and UQD06 parts that interchange dimensionally.
Push-on female couplers
| UQD size | Part number | Hose tail | A | B | C | D | Hex |
|---|---|---|---|---|---|---|---|
| UQD02 | HZ223S10-040400 | 1/4 inch | 22.0 mm | 46.4 mm | 19.0 mm | 15.5 mm | 14.0 mm |
| UQD04 | HZ223S10-060600 | 3/8 inch | 26.5 mm | 61.0 mm | 22.0 mm | 19.9 mm | 19.0 mm |
| UQD06 | HZ223S10-080800 | 1/2 inch | 29.0 mm | 61.0 mm | 25.6 mm | 23.9 mm | 22.0 mm |
Male BSP couplings to ISO 1179-3
| UQD size | Part number | Thread | E | F | G | H | J | Hex |
|---|---|---|---|---|---|---|---|---|
| UQD02 | HZ210510-040200 | 1/8 inch BSP | 16.8 mm | 30.4 mm | 8.1 mm | 13.5 mm | 6.6 mm | 15.0 mm |
| UQD04 | HZ210510-060600 | 3/8 inch BSP | 24.6 mm | 38.2 mm | 11.2 mm | 10.6 mm | 11.1 mm | 22.0 mm |
| UQD06 | HZ210510-080600 | 3/8 inch BSP | 24.6 mm | 41.8 mm | 11.1 mm | 11.0 mm | 14.3 mm | 22.0 mm |
Male ORB couplings to ISO 11926-3
| UQD size | Part number | Thread | E | F | G | H | J | Hex |
|---|---|---|---|---|---|---|---|---|
| UQD02 | HZ213010-040400 | 7/16-20 UNF | 17.3 mm | 29.3 mm | 9.1 mm | 13.5 mm | 6.6 mm | 14.0 mm |
| UQD04 | HZ213010-060600 | 9/16-18 UNF | 19.6 mm | 38.2 mm | 11.1 mm | 10.6 mm | 11.1 mm | 17.0 mm |
| UQD06 | HZ213010-080800 | 3/4-16 UNF | 24.6 mm | 41.8 mm | 11.0 mm | 11.0 mm | 14.3 mm | 22.0 mm |
Dimensions are from the manufacturer data sheet current at the time of writing. Confirm against the issued revision before ordering. Coupling envelopes change between revisions, and a 2 millimetre difference in hex size is the difference between a spanner fitting and not.
Selection
Getting the size and configuration right
Order of operations
Size the coupling to the flow the rack actually needs, then size the hose to the coupling, then check the bend radius against the real cable route. Doing it in any other order produces an assembly that is correct on paper and will not fit in the rack.
Then keep one coupling family and one seal material across the whole site. Mixed coupling families on a single row is the most common liquid cooling problem we are called to, and it cannot be fixed without replacing hardware.
1/4 inch nominal
Lower flow nodes, instrumentation branches and bleed lines. Pairs with 6 mm ID hose. Hex 14 mm on the push-on female.
3/8 inch nominal
The common size for single-socket and mid-range direct-to-chip nodes. Pairs with 10 mm ID hose. Hex 19 mm.
1/2 inch nominal
High flow nodes and multi-socket accelerated servers. Pairs with 13 mm ID hose. Hex 22 mm.
Field serviceable
Made up to a hose tail without crimping equipment. This is what you want holding as an incident spare.
ISO 1179-3 parallel thread
Threads into a manifold or cold plate port with a bonded seal. Common on European and Asian hardware.
ISO 11926-3 O-ring boss
UNF series. Common on North American hardware and on most CDUs sold into Australia, including the Vertiv range.
Supply position
Where these parts come from, and the Danfoss transition
Indigi buys these components direct from the manufacturer rather than through a reseller. If you are specifying them into a project now, you should also know where the business sits, because we would rather tell you than have you find out from a procurement query.
Alfa Gomma S.p.A. entered voluntary liquidation, with a board of receivers appointed by the Court of Milan in May 2025. In July 2026 the board announced the signing of definitive agreements for the sale of the Alfa Gomma Group to Danfoss A/S, with completion expected in the fourth quarter of 2026. Danfoss has described the transaction as creating a leading global player in fluid conveyance. Alfagomma Australia continues to operate, including from Eastern Creek in New South Wales and Knoxfield in Victoria.
| Question | Position as at November 2026 |
|---|---|
| Are the products still available? | Yes. The Australian operation continues, with a national branch and reseller network, so standard hose and coupling sizes remain domestic stock rather than an import |
| Will the part numbers change? | Part numbers are the stable thing in an acquisition. Brand presentation and catalogue structure are what move. Record the part numbers you specify, not just the brand |
| Should I avoid specifying the brand? | No, but specify to performance as well as brand. A line reading "959AE or equivalent: peroxide cured, calcium and zinc free EPDM tube, UL 94 V0 cover, 20 bar working" survives a rebrand. One reading "Alfagomma" alone may not |
| Does it affect warranty on installed components? | An acquisition transfers obligations with the business rather than extinguishing them, but confirm the warranty position in writing at order rather than assuming it. We raise this on every quote |
| Does it change the install or the maintenance? | Not at all. The loop, the coolant chemistry, the commissioning and the maintenance regime are identical regardless of whose name is on the hose |
Sources: the Alfa Gomma S.p.A. in liquidazione board of liquidators announcement, and the Danfoss A/S announcement of the signed definitive agreement. Confirm current status directly before committing a long lead procurement.
Also supplied
Manifolds, rigid pipe and corrugated assemblies
| Component | What to specify | Why it matters |
|---|---|---|
| Rack manifold | Vertical or horizontal, port count and size, integral isolation and bleed per port | Port count locks in your future rack density. Getting it wrong means repiping, not reconfiguring, and no isolation means draining the loop for every cold plate change |
| Stainless steel rigid pipe | Grade, wall thickness, end preparation, cleanliness and passivation on delivery | The rigid run is the part you cannot easily change later, and cleanliness at install sets coolant quality for years. Filtration cannot recover it afterwards |
| Wire braided corrugated assembly | Stainless corrugated core with wire braid, made to length | For runs crossing a movement joint, or absorbing thermal expansion between a riser and a CDU |
| Isolation and drain valves | Ball and needle valves rated to loop pressure and fluid | Designed in per rack and per row at install. Retrofitting isolation into a commissioned loop means draining it |
| Strainers and filtration | Y-strainers and side stream filtration, replaceable elements | The strainer is your early warning system. What comes out of it tells you about corrosion and biological growth before any dashboard does |
| Leak detection | Rope sensing under the rack and in the CDU bund, spot sensors at joints | Must map into a platform someone monitors out of hours, and be function tested on a schedule rather than only at commissioning |
Coverage
Where Indigi works

Brisbane and QLD
Brisbane CBD, Woolloongabba, Eight Mile Plains, Port of Brisbane, Gold Coast, Sunshine Coast, Ipswich, Townsville, Cairns
Head office at Tingalpa. Project delivery and scheduled maintenance across South East Queensland and the north.

Sydney and NSW
Sydney CBD, Parramatta, North Ryde, Macquarie Park, Western Sydney, Newcastle, Wollongong, Canberra (ACT)
Closest to the manufacturer at Eastern Creek, so component lead times into the Sydney colocation corridor are short.

Melbourne and VIC
Melbourne CBD, Port Melbourne, Docklands, Dandenong, Tullamarine, Geelong, Ballarat, regional Victoria
A second manufacturer site at Knoxfield helps Victorian project lead times.

Perth and WA
Perth CBD, Fremantle, Kalgoorlie, Pilbara, regional WA
Components freighted with the install crew so one mobilisation covers supply and fit.
Adelaide and SA
Adelaide CBD, Port Adelaide, Salisbury, Mount Gambier, Whyalla, regional SA
Component supply bundled with scheduled CRAC and UPS maintenance visits to keep travel off the invoice.
Darwin and NT
Darwin CBD, Palmerston, Katherine, Alice Springs, remote NT sites
We will recommend an on-site spares holding. On remote sites freight time, not labour, is the real mean time to repair.
Western Australia, Tasmania and the Pacific Islands
Every item here is quoted rather than priced online, because length, end fittings and quantity change the number. Send a rack elevation and we will come back with an assembly list. Contact us to discuss scheduling.
Questions
Frequently asked questions
Can I use ordinary industrial or hydraulic hose for liquid cooling?
No, and it is the most expensive shortcut available on a liquid cooling project. General purpose rubber hose is not calcium and zinc free, so it leaches ions that precipitate inside cold plate microchannels and reduce flow on individual nodes. It usually carries no flame rating, which creates a fire engineering problem in an occupied hall, and its seal material may not suit your coolant. The failure is slow and presents as thermal throttling months later, which makes it very hard to trace back to the hose.
What is a UQD coupling, and do the sizes interchange between manufacturers?
UQD stands for universal quick disconnect. The sizing and dimensional envelope come from the Open Compute Project specification, which is why several manufacturers all sell UQD02, UQD04 and UQD06 parts that interchange dimensionally. Interchanging dimensionally is not the same as interchanging functionally: flow coefficients, seal materials and spill volumes still differ. Specify one family across a site and record the part numbers.
Why does flat face matter on a liquid cooling coupling?
Two reasons. Spill: a flat-face coupling loses a very small volume of coolant on disconnect rather than a cupful onto a live rack. Air: a non flat-face coupling ingests air on reconnection, and air in a technology cooling loop causes pump cavitation, hot spots inside cold plates and corrosion. Flat face is also simply easier to wipe clean before mating, which keeps particulate out of the loop.
Do you supply assemblies made to length?
Yes, quoted against your rack elevation with the specified end fittings and colour coded cover, and tagged at both ends. We check the lengths against the real cable route rather than the drawing, because minimum bend radius is where paper designs and real racks part company.
How do these parts relate to the Vertiv liquid cooling range?
They are different layers of the same system and they are bought together. The Vertiv range is the equipment: coolant distribution units, rear door heat exchangers and immersion systems. The parts here are the connection layer that joins that equipment to the racks and the cold plates. A CDU without hose, couplings and manifolds does not cool anything.
Can you supply a different brand if our server vendor has mandated one?
Yes. The coolant chemistry and dimensional specification normally come from your server or cold plate vendor, and that specification wins over any preference of ours. Tell us what has been mandated and we will supply and install to it. We are a contractor rather than a single-brand reseller, so we have no reason to argue with a vendor specification.
Related
Where to go next
Send a rack elevation, get an assembly list
Give us the rack layout, the cold plate port types and the flow per node, and we will come back with a component list, made-up assembly lengths, part numbers and an installed price. Indigi Power and Cooling buys these components direct, and is Indigenous and Veteran owned, Supply Nation and ICN Gateway registered.
Data Centre Liquid Cooling Hose, Fittings and Quick Disconnect Couplings
Partner with Us
Reliable Power & Cooling Solutions from Indigi Power & Cooling Expert supply, installation, and contracting services for critical infrastructure across Australia.