Eaton 9SX Marine UPS (1000VA - 3000VA)
The Eaton 9SX Marine is the successor to the market-leading 9130 Marine UPS - a single-phase online double-conversion UPS purpose-built for marine and offshore environments. Available in 1000VA (900W) and 3000VA (2700W) tower configurations, the 9SX Marine is DNV GL type approved (with installation kit and marine filter), delivering zero transfer time power protection with conformal coated boards, vibration absorbers, and high-temperature compatibility for shipboard and offshore platform installations.
With its compact footprint, hot-swappable internal batteries, and support for up to four external battery modules (EBMs), the 9SX Marine can provide hours of runtime for critical onboard systems including bridge equipment, navigation, communications, and automation.
Indigi Power & Cooling supplies, installs, and supports Eaton 9SX Marine UPS systems across Australia and the Pacific. Contact us for an obligation-free quote.
Key Features
DNV GL Type Approved Marine Design
-
DNV GL type approved (when installed with installation kit and marine filter - sold separately)
-
Conformal coated boards for humidity, salt air, and chemical resistance
-
High-temperature environment compatibility
-
Installation kit includes vibration absorbers mounted under the UPS cabinet
-
Mounting rails can be bolted or welded to the deck, bulkhead, or shelf
-
Compact tower form factor designed for space-constrained vessel installations
-
Marine filter included for full DNV GL compliance
Online Double-Conversion Power Protection
The 9SX Marine uses online double-conversion topology with Power Factor Correction (PFC), continuously monitoring and regulating voltage and frequency. Connected equipment is completely isolated from all input power anomalies. Zero transfer time to battery ensures seamless protection during generator switching, frequency variations, and mains disturbances common in marine power systems.
0.9 Output Power Factor - 28% More Power
With a 0.9 output power factor, the 9SX Marine delivers up to 28% more usable watts than equivalent VA-rated UPS systems with lower power factors - protecting more critical equipment per unit and eliminating the need to oversize.
Eaton ABM Battery Management
Advanced Battery Management (ABM) uses an intelligent three-stage charging technique that extends battery service life by up to 50% compared to conventional float charging. The 9SX Marine also provides a recommended battery replacement date based on continuous battery condition monitoring - removing guesswork from maintenance scheduling on board vessels where service resources are limited.
Hot-Swappable Internal Batteries and EBMs
Internal batteries are hot-swappable - replacement without powering down critical systems. Up to four external battery modules (EBMs) can be added for extended runtime, automatically recognised by the UPS without configuration. Runtime can be extended from minutes to hours depending on the number of EBMs fitted.
Marine Mode and Frequency Converter Operation
Configurable for Marine Mode (output frequency follows input frequency), frequency converter operation from 50Hz to 60Hz, and 60Hz to 50Hz - supporting vessels operating in different international waters and power environments.
Graphical LCD Display
7-language graphical LCD with adjustable display angle for optimal visibility in both tower and rack orientations. Provides UPS status, measurements, alarm history, energy consumption, load segment control, and battery runtime at a glance. LCD position adjustable for tower and shelf installations.
Load Segment Control
Two independently controllable outlet groups enable priority-based shutdown of non-essential equipment to maximise battery runtime for the most critical devices during an extended outage.
Energy Metering
The 9SX Marine can meter energy consumption in kWh - monitored via the LCD or Eaton Intelligent Power Manager software for vessel energy management.
Intelligent Power Software Integration
Compatible with Eaton Intelligent Power Manager (IPM) and Intelligent Power Protector, integrating with virtualisation environments and supporting automated graceful shutdown of servers and computers during extended battery operation.
Internal Automatic Static Bypass
Internal automatic static bypass provides service continuity in the event of an internal UPS fault. An optional external maintenance bypass switch is available for UPS replacement without powering down connected systems.
Applications
The Eaton 9SX Marine provides advanced protection for critical single-phase onboard systems:
-
Bridge systems and integrated bridge platforms
-
Navigation systems (ECDIS, radar, AIS, GPS, chartplotters)
-
Communication systems (VHF, GMDSS, satellite, SSB)
-
Small computer and automation systems
-
Voyage Data Recorders (VDR)
-
CCTV and intercom systems
-
Ship management software workstations
-
Offshore platform instrumentation and control
Technical Specifications
| Specification | 9SX 1000 Marine | 9SX 3000 Marine |
|---|---|---|
| Part Number | 9SX1000IM | 9SX3000IM |
| Power Rating | 1000VA / 900W | 3000VA / 2700W |
| Topology | Online double-conversion with PFC | Online double-conversion with PFC |
| Output Power Factor | 0.9 | 0.9 |
| Efficiency (online, full load) | 92.4% | 92.4% |
| Efficiency (ECO mode) | 97.4% | 97.4% |
| Input Connection | 1 x IEC C14 (10A) | 1 x IEC C20 (16A) |
| Input Nominal Voltage | 200/208/220/230/240V | 200/208/220/230/240V |
| Input Voltage Range | 190-276V (no derating) / 120-276V with derating | 200-276V (no derating) / 140-276V with derating |
| Input Frequency Range | 40-70Hz, 50/60Hz autoselect, frequency converter mode | 40-70Hz, 50/60Hz autoselect, frequency converter mode |
| Input Power Factor | >0.99 | >0.99 |
| Output Connections | 6 x IEC C13 (10A) | 8 x IEC C13 (10A) + 1 x IEC C19 (16A) |
| Switched Outlet Groups | 2 | 2 |
| Output Voltage Regulation | 200/208/220/230/240V +/-2% | 200/208/220/230/240V +/-2% |
| Output UTHD (linear load) | Less than 3% | Less than 3% |
| Transfer Time | 0 ms | 0 ms |
| Battery Type | Sealed VRLA 12V / 9Ah | Sealed VRLA 12V / 9Ah |
| Battery Quantity | 3 | 8 |
| Hot-Swappable Batteries | Yes | Yes |
| Max EBMs | 4 | 4 |
| Runtime at full load | Approx 6 min | Approx 6 min |
| Runtime at half load | Approx 15.5 min | Approx 15.5 min |
| Noise Level | Less than 41 dB | Less than 45 dB |
| Operating Temperature | 0 to 40 degrees C | 0 to 40 degrees C |
| Humidity | 0-96% non-condensing | 0-96% non-condensing |
| Altitude | Up to 3,000m | Up to 3,000m |
| Colour | Black | Black |
| Dimensions (H x W x D) | 252 x 160 x 387 mm | 346 x 214 x 412 mm |
| Weight | 15 kg | 34 kg |
| Warranty | 2 years (UPS and batteries) | 2 years (UPS and batteries) |
Runtime Table (Approximate - Minutes)
| Load | 9SX 1000 | 9SX 1000 + 1 EBM | 9SX 1000 + 4 EBM | 9SX 3000 |
|---|---|---|---|---|
| 300W | 24 min | 90 min | 320 min | - |
| 500W | 14 min | 56 min | 200 min | - |
| 800W | 7 min | - | - | - |
| 900W (full load) | 6 min | - | - | 6 min |
| 1350W | - | - | - | - |
| 2700W (full load) | - | - | - | 6 min |
Runtime values are approximate and vary with battery age, temperature, and load characteristics.
Communications and Connectivity
| Interface | Detail |
|---|---|
| USB port | 1 x USB (HID compliant) |
| Serial port | 1 x RS-232 |
| Remote Power Off | Mini-terminal block (configurable) |
| Output relay | Mini-terminal block (2 outputs, 1 input dry contact) |
| Communication slot | 1 slot for optional Network-M2, Network-MS, ModBus-MS, or Relay-MS card |
| Software | Eaton Intelligent Power Manager (IPM), Eaton Intelligent Power Protector |
Certifications and Compliance
| Standard / Approval | Scope |
|---|---|
| DNV GL Type Approval | Approved with installation kit and marine filter |
| IEC/EN 62040-1 | Safety |
| IEC/EN 62040-2 | EMC |
| IEC 60945 | Marine EMC |
| CE | European conformity |
| CB Report (TUV) | International safety |
| cULus | North American safety |
| EAC | Eurasian conformity |
| RCM | Australian regulatory compliance mark |
| KC | Korean conformity |
Important: DNV GL type approval applies when the 9SX Marine is installed with the Eaton installation kit (vibration absorbers) and the Eaton marine filter. Both are required and must be ordered separately.
Available Accessories
| Accessory | Description |
|---|---|
| Installation Kit | Vibration absorbers - required for DNV GL type approval |
| Marine Filter | EMC filter - required for DNV GL type approval |
| EBM 1000 (9SXEBM36T) | External battery module for 9SX 1000 Marine |
| EBM 3000 (9SXEBM96T) | External battery module for 9SX 3000 Marine (2m battery cable required) |
| Network-M2 Card | Gigabit Web/SNMP network management card |
| Network-MS Card | Web/SNMP network management card |
| ModBus-MS Card | ModBus/JBus communications card |
| Relay-MS Card | Relay output communications card |
| External Maintenance Bypass | Manual bypass for UPS replacement without load interruption |
Supply, Installation and Support
Indigi Power & Cooling supplies, installs, and supports Eaton 9SX Marine UPS systems across Australia and the Pacific region, including Papua New Guinea and offshore vessel operations. Our team can advise on DNV GL compliance requirements including the installation kit and marine filter, EBM configurations for extended runtime, and appropriate communication card selection for vessel monitoring systems.