Vertiv Liebert GXT5-10KIRT5UXLN 10kVA Online Double Conversion UPS Australia
Vertiv Liebert GXT5-10KIRT5UXLN 10kVA Online Double Conversion UPS Australia
Vertiv Liebert GXT5 / Single Phase Online UPS / 10kVA
The Vertiv Liebert GXT5-10KIRT5UXLN is a 10,000VA / 10,000W single phase, online double conversion hardwired rack or tower UPS with unity power factor and efficiency up to 95%, supplied, installed and maintained across Australia by Indigi Power and Cooling. It delivers continuous, fully conditioned power to full server racks, data centre rows and large comms rooms, and ships with a Vertiv RDU120 network card and a 3-year warranty. Indigi Power and Cooling is an Indigenous and Veteran-owned critical power specialist, Supply Nation and ICN Gateway registered.
The Vertiv Liebert GXT5-10KIRT5UXLN is the flagship 10kVA member of the Liebert GXT5 online double conversion family, sized at 10,000VA and, thanks to a unity output power factor of 1.0, a full 10,000 watts of usable output. Online double conversion (VFI classification) means the connected load is always powered from a regenerated sine wave, fully isolated from the raw mains, so voltage sags, surges, frequency drift, harmonics and brownouts never reach your equipment. For data centre rows, high-density server racks and mission-critical comms rooms that cannot tolerate a break in clean power, this is the topology that matters.
In a 5U chassis that installs as a rack unit or a free-standing tower, the GXT5-10KIRT5UXLN packs a color graphic LCD with gravity-sensing orientation, individually programmable output sockets, hot-swappable batteries and a Vertiv Liebert IntelliSlot RDU120 network card in the box. It uses a hardwired 230VAC input with common or split bypass, runs at up to 95% efficiency in online mode and up to 98% in ECO mode, and Indigi Power and Cooling supplies it Australia-wide with optional installation, commissioning and ongoing maintenance from our Brisbane, Sydney and Melbourne hubs.
Vertiv Liebert GXT5 overview
Vertiv Liebert GXT5 flexible online UPS range for edge, server room and data centre applications.
Why the GXT5-10KIRT5UXLN leads its class
Unity power factor (1.0)
10,000VA equals a full 10,000W of real power. You can load it with more IT equipment than a 0.9 power factor UPS of the same VA rating, protecting more of the rack from a single unit.
True online protection
Double conversion (VFI) isolates the load from all nine common power problems with zero transfer time, delivering a pure sine wave regardless of what the mains is doing.
Efficiency up to 95% / 98% ECO
Up to 95% efficiency in online double conversion mode and up to 98% in ECO mode lowers running cost and heat load in the room, and it is Energy Star certified.
Intelligent battery management
Battery health status and replacement-date prediction, temperature-compensated charging and hot-swappable modules extend service life and cut unplanned downtime.
Network card included
A Vertiv Liebert IntelliSlot RDU120 card ships in the box for SNMP, web and Power Insight remote monitoring, with no extra accessory to buy.
Scalable runtime
Add a GXT5-EBC192VRT3U external battery cabinet to extend backup from 2 minutes to roughly 7 minutes at full 10kW load, with auto-detection for accurate runtime reporting.
GXT5-10KIRT5UXLN specifications
| Part number | GXT5-10KIRT5UXLN |
|---|---|
| Rating (VA / W) | 10,000VA / 10,000W (unity power factor 1.0) |
| Topology | Online double conversion (VFI), single phase 230V |
| Form factor | 5U convertible rack / tower |
| Efficiency | Up to 95% online double conversion, up to 98% ECO mode |
| Dimensions (W x D x H) | 430 x 630 x 217 mm |
| Unit weight | 74.5 kg |
| Input connection | Hardwired, 230 VAC nominal, 50/60 Hz, common or split bypass |
| Output receptacles | Hardwired output plus 4 x IEC 60320 C19 and 4 x IEC 60320 C13, pure sine wave |
| Backup time (internal) | 2 min at 100% load, 7 min at 50% load |
| Backup time (+1 cabinet) | 7 min at 100% load, 19 min at 50% load |
| Battery type | Valve-regulated, non-spillable lead acid, hot-swappable |
| Communications | RDU120 network card (included), USB, RS232, dry contacts, Power Insight software |
| Operating temperature | 0 to 40 degrees Celsius |
| Surge and safety | EN 61000-4-5, EN 62040-1, RCM marked |
| Warranty | 3-year Vertiv limited warranty (ANZ) |
GXT5 5kVA to 20kVA range at a glance
The GXT5-10KIRT5UXLN shares its high-capacity online double conversion platform with the rest of the large-frame Liebert GXT5 family. If your load is likely to grow, the following models step up in capacity and expandable runtime.
| Model | Rating | Runtime at 100% | Weight |
|---|---|---|---|
| GXT5-5000IRT5UXLN | 5000VA / 5000W | 7 min | 70.8 kg |
| GXT5-6000IRT5UXLN | 6000VA / 6000W | 5.5 min | 70.8 kg |
| GXT5-8000IRT5UXLN | 8000VA / 8000W | 3.5 min | 74.5 kg |
| GXT5-10KIRT5UXLN | 10,000VA / 10,000W | 2 min | 74.5 kg |
| GXT5-16KIRT9UXLN | 16,000VA / 16,000W | 3.5 min | 135.2 kg |
| GXT5-20KIRT9UXLN | 20,000VA / 20,000W | 2.5 min | 135.2 kg |
Applications for the GXT5-10KIRT5UXLN
At 10kVA the GXT5-10KIRT5UXLN is matched to large critical loads that demand true online protection: a fully populated server rack, a data centre row, a high-density comms room, a hospital imaging suite, an industrial control room, or a small on-premise data centre. Because it is online double conversion rather than line-interactive, it suits sites with unstable or generator-backed power where frequency and voltage wander, and its hardwired input with common or split bypass supports serviceable, maintainable installations.
- Full server racks and high-density compute in on-premise and colocation data centres
- Data centre rows, core network and comms rooms with concentrated critical load
- Industrial control, SCADA and process automation cabinets requiring clean power
- Healthcare imaging, diagnostic and laboratory suites needing continuous supply
- Building services, security and life-safety head-ends across large facilities
For different capacities, browse the Vertiv single phase UPS range, and if you are protecting a full rack or room, pair the UPS with cooling through our server room cooling service. Not sure of your runtime target? Use the UPS runtime and battery sizing calculator.
GXT5-10KIRT5UXLN vs a typical line-interactive UPS
At this capacity choosing a line-interactive UPS to save money puts an entire rack or row at risk. The table below shows why the online double conversion GXT5 is the safer choice for concentrated critical loads.
| Feature | GXT5-10KIRT5UXLN | Typical line-interactive UPS |
|---|---|---|
| Topology | Online double conversion, zero transfer time | Transfers to battery, 2 to 10 ms break |
| Power factor | 1.0 (10,000W from 10,000VA) | Usually 0.9 or lower |
| Output waveform | Pure sine wave, always regenerated | Sine on battery, raw mains otherwise |
| Remote management | RDU120 network card included | Network card often extra |
| Runtime expansion | External battery cabinets with auto-detect | Limited or none |
Installation and maintenance across Australia
The GXT5-10KIRT5UXLN uses a hardwired 230VAC input with common or split bypass, so all supply, distribution, rack integration and building connection work must be carried out by a licensed electrician. Indigi Power and Cooling provides single phase UPS installation and commissioning nationally, including hardwired connection, bypass configuration, rack mounting, battery cabinet connection, load transfer and configuration of the network card and shutdown software.
To protect your investment and keep the warranty valid, batteries and electronics should be inspected on a regular schedule. Our UPS maintenance service covers testing, battery health checks and firmware updates, and annual maintenance plans keep your GXT5 fleet compliant and reliable. Internal batteries are serviceable using the GXT5-192VBATKIT, and the GXT5-EBC192VRT3U external cabinet extends runtime when you need it.
Australian sites bring their own power quality challenges, from long feeder runs and voltage sag in regional areas to generator changeover on backed-up sites, and these are exactly the conditions online double conversion is built to ride through. All fixed electrical connection work must comply with AS/NZS 3000 wiring rules and be performed by a licensed electrician, and Indigi Power and Cooling handles that side of the deployment for you so the GXT5 is installed, labelled and commissioned correctly the first time.
Frequently asked questions
Is the Vertiv GXT5-10KIRT5UXLN single phase?
Yes. The GXT5-10KIRT5UXLN is a single phase 230V UPS with a single phase input and single phase output, which is why it belongs in the Vertiv single phase (1:1) range.
How much backup runtime does it provide?
On its internal batteries it delivers about 2 minutes at full 10,000W load and 7 minutes at 50% load. Adding one GXT5-EBC192VRT3U external battery cabinet extends this to roughly 7 minutes at full load and 19 minutes at half load, and further cabinets scale runtime for longer holdover.
Can it be used as a rack or a tower?
Both. It is a 5U convertible chassis that racks into a standard 19-inch cabinet or stands vertically as a tower, and the color LCD rotates automatically to suit the orientation.
What efficiency does the GXT5 achieve?
Up to 95% in online double conversion mode and up to 98% in ECO mode. It is Energy Star certified, which reduces both running cost and the heat it adds to the room.
Does it include a network management card?
Yes. A Vertiv Liebert IntelliSlot RDU120 network card is supplied in the box for SNMP, web and Vertiv Power Insight remote monitoring, along with USB, RS232 and dry-contact connectivity.
Is the GXT5-10KIRT5UXLN hardwired?
Yes. It uses a hardwired 230VAC input with common or split bypass and a hardwired output, plus 4 x IEC C19 and 4 x IEC C13 receptacles, so a licensed electrician must complete the fixed connection to AS/NZS 3000.
Can Indigi install and maintain it anywhere in Australia?
Yes. We supply, install, commission and maintain the GXT5 range nationwide from our Brisbane, Sydney and Melbourne hubs, covering Perth, Adelaide, Darwin and regional sites on scheduled visits.
Related products and services
- Vertiv Liebert GXT5-6000IRT5UXLN 6000VA online UPS
- Vertiv Liebert GXT5-8000IRT5UXLN 8000VA online UPS
- Vertiv Liebert GXT5-16KIRT9UXLN 16kVA online UPS
- Full Vertiv single phase UPS range
- Single phase UPS installation and commissioning
- UPS maintenance plans
|
Get GXT5-10KIRT5UXLN pricing, stock and installation Tell us your load, site and runtime target and we will size, supply and install the right Vertiv GXT5 UPS. Indigi Power and Cooling is Indigenous and Veteran-owned, Supply Nation and ICN Gateway registered. Contact Indigi Power and Cooling |

Partner with Us
Reliable Power & Cooling Solutions from Indigi Power & Cooling Expert supply, installation, and contracting services for critical infrastructure across Australia.