Skip to product information
1 of 2

Vertiv Liebert GXT5-5000IRT5UXLN 5000VA Online Double Conversion UPS Australia

Vertiv Liebert GXT5-5000IRT5UXLN 5000VA Online Double Conversion UPS Australia

Vertiv Liebert GXT5  /  Single Phase Online UPS  /  5000VA

The Vertiv Liebert GXT5-5000IRT5UXLN is a 5000VA / 5000W single phase, online double conversion rack or tower UPS with unity power factor and efficiency up to 95%, supplied, installed and maintained across Australia by Indigi Power and Cooling. It delivers continuous, fully conditioned power to server racks, network cores and edge data centre loads through a hardwired input and output plus IEC C19 and C13 receptacles, and ships with a Vertiv RDU120 network card and a 3-year warranty. Indigi Power and Cooling is an Indigenous and Veteran-owned critical power specialist, Supply Nation and ICN Gateway registered.

The Vertiv Liebert GXT5-5000IRT5UXLN is the 5kVA member of the Liebert GXT5 online double conversion family, sized at 5000VA and, thanks to a unity output power factor of 1.0, a full 5000 watts of usable output. Online double conversion (VFI classification) means the connected load is always powered from a regenerated sine wave, fully isolated from the raw mains, so voltage sags, surges, frequency drift, harmonics and brownouts never reach your equipment. For server rooms, network cores and edge data centre cabinets that cannot tolerate a break in clean power, this is the topology that matters.

In a 5U chassis that installs as a rack unit or a free-standing tower, the GXT5-5000IRT5UXLN packs a color graphic LCD with gravity-sensing orientation, individually programmable output sockets, hot-swappable batteries and a Vertiv Liebert IntelliSlot RDU120 network card in the box. It runs at up to 95% efficiency in online mode and up to 98% in ECO mode, and Indigi Power and Cooling supplies it Australia-wide with optional installation, commissioning and ongoing maintenance from our Brisbane, Sydney and Melbourne hubs. Because it is a hardwired 5kVA unit, fixed input and output connection is carried out by a licensed electrician as part of a compliant deployment.

Vertiv Liebert GXT5 overview

Vertiv Liebert GXT5 flexible online UPS range for edge and server room applications.

Why the GXT5-5000IRT5UXLN leads its class

Unity power factor (1.0)

5000VA equals a full 5000W of real power. You can load it with more IT equipment than a 0.9 power factor UPS of the same VA rating, saving rack space and cost.

True online protection

Double conversion (VFI) isolates the load from all nine common power problems with zero transfer time, delivering a pure sine wave regardless of what the mains is doing.

Efficiency up to 95% / 98% ECO

Up to 95% in online double conversion mode and up to 98% in ECO mode lowers running cost and heat load in the rack, and it is Energy Star certified.

Intelligent battery management

Battery health status and replacement-date prediction, temperature-compensated charging and hot-swappable modules extend service life and cut unplanned downtime.

Network card included

A Vertiv Liebert IntelliSlot RDU120 card ships in the box for SNMP, web and Power Insight remote monitoring, with no extra accessory to buy.

Scalable runtime

Add a GXT5-EBC192VRT3U external battery cabinet to extend backup from 7 minutes to around 19 minutes at full load, with auto-detection for accurate runtime reporting.

GXT5-5000IRT5UXLN specifications

Table: Vertiv Liebert GXT5-5000IRT5UXLN key technical specifications
Part number GXT5-5000IRT5UXLN
Rating (VA / W) 5000VA / 5000W (unity power factor 1.0)
Topology Online double conversion (VFI), single phase 230V
Form factor 5U convertible rack / tower
Efficiency Up to 95% online double conversion, up to 98% ECO mode
Dimensions (W x D x H) 430 x 630 x 217 mm
Unit weight 70.8 kg
Input connection Hardwired terminal block, 230 VAC nominal, 50 / 60 Hz auto-sensing
Output connections Hardwired output plus 2 x IEC 60320 C19 and 6 x IEC 60320 C13, pure sine wave
Backup time (internal) 7 min at 100% load, 18.5 min at 50% load
Backup time (+1 cabinet) 19 min at 100% load, 48 min at 50% load
Battery type Valve-regulated, non-spillable lead acid, hot-swappable
Communications RDU120 network card (included), USB, RS232, dry contacts, Power Insight software
Operating temperature 0 to 40 degrees Celsius
Surge and safety EN 61000-4-5, EN 62040-1, RCM marked
Warranty 3-year Vertiv limited warranty (ANZ)

GXT5 5kVA to 20kVA range at a glance

The GXT5-5000IRT5UXLN sits at the entry of the larger Liebert GXT5 platform for server rooms and edge data centres. If your load is likely to grow, the following hardwired models step up through the 5U and 9U range.

Table: Vertiv Liebert GXT5 hardwired single phase range, 5000VA to 20000VA
Model Rating Runtime at 100% Weight
GXT5-5000IRT5UXLN 5000VA / 5000W 7 min 70.8 kg
GXT5-6000IRT5UXLN 6000VA / 6000W 5.5 min 70.8 kg
GXT5-8000IRT5UXLN 8000VA / 8000W 3.5 min 74.5 kg
GXT5-10KIRT5UXLN 10000VA / 10000W 2 min 74.5 kg
GXT5-16KIRT9UXLN 16000VA / 16000W 3.5 min 135.2 kg
GXT5-20KIRT9UXLN 20000VA / 20000W 2.5 min 135.2 kg

Applications for the GXT5-5000IRT5UXLN

At 5000VA the GXT5-5000IRT5UXLN is matched to concentrated critical loads that demand true online protection: a fully populated server rack, a network core or aggregation layer, a storage array, a small edge data centre, a broadcast or industrial control room, or a medical imaging suite. Because it is online double conversion rather than line-interactive, it suits sites with unstable or generator-backed power where frequency and voltage wander, and its hardwired input handles the higher current an integrated 5kW load draws.

  • Edge and micro data centre racks in retail, industrial and remote sites
  • Network core, aggregation and storage cabinets carrying a full rack of load
  • Server rooms consolidating multiple servers and appliances onto one UPS
  • Healthcare, imaging and laboratory systems requiring clean, continuous power
  • Broadcast, industrial control and building management head-ends

For larger loads, step up through the Vertiv single phase UPS range, and if you are protecting a full rack or room, pair the UPS with cooling through our server room cooling service. Not sure of your runtime target? Use the UPS runtime and battery sizing calculator.

GXT5-5000IRT5UXLN vs a typical line-interactive UPS

At 5kVA the temptation is to save money with a line-interactive UPS, but a concentrated server or network load is exactly where that compromise costs the most. The table below shows why the online double conversion GXT5 is the safer choice for critical loads.

Table: Online double conversion GXT5-5000IRT5UXLN compared with a typical line-interactive UPS
Feature GXT5-5000IRT5UXLN Typical line-interactive UPS
Topology Online double conversion, zero transfer time Transfers to battery, 2 to 10 ms break
Power factor 1.0 (5000W from 5000VA) Usually 0.9 or lower
Output waveform Pure sine wave, always regenerated Sine on battery, raw mains otherwise
Remote management RDU120 network card included Network card often extra
Runtime expansion External battery cabinets with auto-detect Limited or none

Installation and maintenance across Australia

The GXT5-5000IRT5UXLN is a hardwired 5kVA unit, so its fixed input and output connection, rack integration and building supply work must be carried out by a licensed electrician. Indigi Power and Cooling provides single phase UPS installation and commissioning nationally, including rack mounting, terminal-block termination, battery cabinet connection, load transfer and configuration of the network card and shutdown software.

To protect your investment and keep the warranty valid, batteries and electronics should be inspected on a regular schedule. Our UPS maintenance service covers testing, battery health checks and firmware updates, and annual maintenance plans keep your GXT5 fleet compliant and reliable. Internal batteries are serviceable using the GXT5-192VBATKIT, and the GXT5-EBC192VRT3U external cabinet extends runtime when you need it.

Australian sites bring their own power quality challenges, from long feeder runs and voltage sag in regional areas to generator changeover on backed-up sites, and these are exactly the conditions online double conversion is built to ride through. All fixed electrical connection work must comply with AS/NZS 3000 wiring rules and be performed by a licensed electrician, and Indigi Power and Cooling handles that side of the deployment for you so the GXT5 is installed, labelled and commissioned correctly the first time.

Frequently asked questions

Is the Vertiv GXT5-5000IRT5UXLN single phase?

Yes. The GXT5-5000IRT5UXLN is a single phase 230V UPS with a single phase input and single phase output, which is why it belongs in the Vertiv single phase (1:1) range.

How much backup runtime does it provide?

On its internal batteries it delivers about 7 minutes at full 5000W load and 18.5 minutes at 50% load. Adding one GXT5-EBC192VRT3U external battery cabinet extends this to roughly 19 minutes at full load and 48 minutes at half load.

How is the GXT5-5000IRT5UXLN connected?

It uses a hardwired terminal-block input and a hardwired output, plus 2 x IEC C19 and 6 x IEC C13 receptacles for flexible rack cabling. Fixed connection must be completed by a licensed electrician to AS/NZS 3000.

What efficiency does the GXT5 achieve?

Up to 95% in online double conversion mode and up to 98% in ECO mode. It is Energy Star certified, which reduces both running cost and the heat it adds to the rack.

Does it include a network management card?

Yes. A Vertiv Liebert IntelliSlot RDU120 network card is supplied in the box for SNMP, web and Vertiv Power Insight remote monitoring, along with USB, RS232 and dry-contact connectivity.

What warranty comes with the GXT5-5000IRT5UXLN?

It carries a 3-year Vertiv limited warranty for the Australia and New Zealand market. Regular maintenance and correct installation keep the warranty valid.

Can Indigi install and maintain it anywhere in Australia?

Yes. We supply, install, commission and maintain the GXT5 range nationwide from our Brisbane, Sydney and Melbourne hubs, covering Perth, Adelaide, Darwin and regional sites on scheduled visits.

Related products and services

Get GXT5-5000IRT5UXLN pricing, stock and installation

Tell us your load, site and runtime target and we will size, supply and install the right Vertiv GXT5 UPS. Indigi Power and Cooling is Indigenous and Veteran-owned, Supply Nation and ICN Gateway registered.

Contact Indigi Power and Cooling
View full details
Contact form

Partner with Us

Reliable Power & Cooling Solutions from Indigi Power & Cooling
Expert supply, installation, and contracting services for critical infrastructure across Australia.

Request a Quote